ESUPPLY / tender_241969 / rfq_246695
长者与有特殊需要人士庇护设施建设
采购范围
- 项目编号
- tender_241969 / rfq_246695
- 采购方
- Dubai Municipality
- 发布
- 2026-10-12
- 截标
- 2026-11-05 08:00 GST
长者与有特殊需要人士庇护设施建设
应标准备
准备对应型号与规格、供货或施工业绩、本地交付计划及技术响应;按项目清单核对数量、验收和参与条件。
公告原文
Project Details Project Code tender_241969 Project Title PJ-30067 ELDERLY AND PEOPLE OF DETERMINATION SHELTERS Opportunity Details Description Note:: GENERAL REQUIREMENTS - Note:: General Notes: - Note:: ● Any items required in General requierments and has no item in BOQ will be considered subsidiary and included in the prices of the other items). - Note:: ● Total amount of General requierments must be not Exceeding 5 % of the Total amount of financial offer,if the Bidder failure to comply/adhere to the mentioned percentage , Dubai Municipality will entitled to reject the offer. - Note:: Contractual Requirements - Note:: Performance Security - Note:: Note: DM will reimburse the CONTRACTOR for Performance Security fees at cost, supported by the surety’s invoice. For the avoidance of doubt, the amount specified in the Bill of Quantities is only indicative and shall not be paid to the Contractor. - Note:: The maximum amount for reimbursement of Performance Security fees shall not exceed the ceiling price, calculated as follows: Performance security amount = 0.3% x (number of quarters in contract period) x (bidder price) x 10% (performance security amount) - A: “Bidder is not required to price it ; the amount will be calculating automatically regarding to the equations in the Grand Summary and will be including in Bidder's total price , all conditions and requirements that mentioned in the Preamble will be applied.” - 1 Item Note:: Insurance of the Works - Note:: Note: DM will reimburse the CONTRACTOR for insurance of work fees at cost, supported by the invoice. For the avoidance of doubt, the amount specified in the Bill of Quantities is only indicative and shall not be paid to the Contractor. - Note:: The maximum amount for reimbursement of insurance of work fees shall not exceed the ceiling price and the ceiling price shall be equal to 0.15% of the bidder price. - B: “Bidder is not required to price it ; the amount will be calculating automatically regarding to the equations in the Grand Summary and will be including in Bidder's total price , all conditions and requirements that mention... Notes Supply Category Other Response Currency AED Opportunity Publication Date 12/10/2026 12:55 Closing date/time 05/11/2026 08:00 Published Lots Published Lots Row Number Icon Column Code Title Closing date/time Action Column 1 RFQ/RFP rfq_246695 PJ-30067 ELDERLY AND PEOPLE OF DETERMINATION SHELTERS 05/11/2026 08:00 Buyer Details Buyer Organisation Dubai Municipality Contact Email Zoom 100% Zoom 75% Zoom 50% Zoom 25% Date & Time of Print: 13/10/2026 09:16:31 - Time Zone: Gulf Standard Time Buyer Organisation: Dubai Municipality Overview Overview RFQ/RFP Code rfq_246695 Title PJ-30067 ELDERLY AND PEOPLE OF DETERMINATION SHELTERS Description Status Running RFQ/RFP Settings RFQ/RFP Settings Online Response Required: Yes Event Currency AED RFQ/RFP Publication 12/10/2026 12:51 Closing 05/11/2026 08:00:00 Time Limit for Expressing Interest 05/11/2026 08:00:00 Awarding Strategy Best Score Additional Information Section Section Description Tender Bond Title Description Value Assigned by Buyer Tender Bond Amount Tender Bond Amount 260,000 Type of Invitation Type of Invitation Contractors Invitation Letter Invitation Letter PJ-30067 Inv.Ltr rev.02.pdf 441 KB Section Section Description PO Details Title Description Value Assigned by Buyer PO Number PO Number Envelopes Envelopes Qualification Envelope Yes Technical Envelope Yes Commercial Envelope Yes Qualification Envelope Qualification Envelope General Attachments Not Allowed Contact Details Contact Details Question Description Question Type Contact Person Name Please Enter Contact Person Name Text Contact Number Please Enter a Direct / Mobile Contact Number Text Code of Conduct Code of Conduct Question Description Code of Conduct على جميع الموردين الالتزام بمدونة مبادئ السلوك أثناء عملية إعداد وتقديم العروض والمقترحات أو أي إجراءات ذات علاقة مع البلدية وتعتبر جزء من الشروط العامة All suppliers must adhere to the Code of Conduct during the process of preparing and submitting offers and proposals or any procedures related to the municipality and are considered part of the general conditions. NDA NDA Question Description CONFIDENTIAL DISCLOSURE AGREEMENT (NDA) على جميع الموردين الالتزام بتوقيع نموذج عدم الإفشاء أثناء عملية إعداد وتقديم العروض مع البلدية وأرفاقه مع العرض المقدم وتعتبر جزء من الشروط العامة All suppliers are obligated to sign a non-disclosure Agreement (NDA) during the process of preparing and submitting offers with Dubai Municipality and attached with the submitted offer form part of the general conditions Tender Bond Tender Bond Question Description Tender Bond Form 2020 الضمان الابتدائي Performance Bank Guarantee Performance Bank Guarantee Question Description Performance Bank Guarantee Form 2020 الضمان النهائي Trade License Trade License Question Description Question Type Trade License Classification Please specify your Trade License type if its Local Option List Trade License Classification If No please specify Text Sustainability Sustainability Question Description Sustainable Policy سياسة الشراء المستدام Criteria to evaluate DM suppliers’ commitment to apply sustainability معايير تقييم التزام موردي بلدية دبي بتطبيق الاستدامة قانون رقم ( 12 ) لسنة 2020 بشأن العُقود وإدارة المخازن في حُكومة دبي قانون رقم ( 12 ) لسنة 2020 بشأن العُقود وإدارة المخازن في حُكومة دبي Question Description قانون رقم ( 12 ) لسنة 2020 يرجى الاطلاع على القانون المستند عليه في إجراءات التعاقد في حكومة دبي LAW ( 12 ) for the year 2020 Please find the attached Contracts and Warehouse Management in the Government of Dubai LAW 12 for the year 2020 that Dubai government uses as a reference in their contractual procedure Information Security Information Security Question Description Information Security Article وثيقة اشتراطات أمن المعلومات إجراءات التظلم إجراءات التظلم Question Description إجراءات التظلم من القرارات الصادرة استناداً لقانون العقود وإدارة المخازن في حكومة دبي عزيزي المورد في حال رغبتكم تقديم تظلم عن الإجراءات والجزاءات التعاقدية المتخذة بحقكم، يمكنكم تقديم خطاب تظلم مع المستندات الداعمة للجنة المختصة وذلك خلال 30 يوم من تاريخ علمكم بالإجراءات المتخذة بحقكم من خلال البريد الالكتروني cgc@dm.gov.ae Contact Details Contact Details Question Description Question Type Contact Person Name Please Enter Contact Person Name Text Contact Number Please Enter a Direct / Mobile Contact Number Text Code of Conduct Code of Conduct Question Description Code of Conduct على جميع الموردين الالتزام بمدونة مبادئ السلوك أثناء عملية إعداد وتقديم العروض والمقترحات أو أي إجراءات ذات علاقة مع البلدية وتعتبر جزء من الشروط العامة All suppliers must adhere to the Code of Conduct during the process of preparing and submitting offers and proposals or any procedures related to the municipality and are considered part of the general conditions. NDA NDA Question Description CONFIDENTIAL DISCLOSURE AGREEMENT (NDA) على جميع الموردين الالتزام بتوقيع نموذج عدم الإفشاء أثناء عملية إعداد وتقديم العروض مع البلدية وأرفاقه مع العرض المقدم وتعتبر جزء من الشروط العامة All suppliers are obligated to sign a non-disclosure Agreement (NDA) during the process of preparing and submitting offers with Dubai Municipality and attached with the submitted offer form part of the general conditions Tender Bond Tender Bond Question Description Tender Bond Form 2020 الضمان الابتدائي Performance Bank Guarantee Performance Bank Guarantee Question Description Performance Bank Guarantee Form 2020 الضمان النهائي Trade License Trade License Question Description Question Type Trade License Classification Please specify your Trade License type if its Local Option List Trade License Classification If No please specify Text SUSTAINABILITY SUSTAINABILITY Question Description Sustainable Policy سياسة الشراء المستدام Criteria to evaluate DM suppliers' commitment to apply sustainability معايير تقييم التزام موردي بلدية دبي بتطبيق الاستدامة قانون رقم ( 12 ) لسنة 2020 بشأن العُقود وإدارة المخازن في حُكومة دبي قانون رقم ( 12 ) لسنة 2020 بشأن العُقود وإدارة المخازن في حُكومة دبي Question Description قانون رقم ( 12 ) لسنة 2020 يرجى الاطلاع على القانون المستند عليه في إجراءات التعاقد في حكومة دبي LAW ( 12 ) for the year 2020 Please find the attached Contracts and Warehouse Management in the Government of Dubai LAW 12 for the year 2020 that Dubai government uses as a reference in their contractual procedure Noon Work Ban Noon Work Ban Question Description Noon Work Ban حظر العمل وقت الظهيرة Contact Details Contact Details Question Description Question Type Contact Person Name Please Enter Contact Person Name Text Contact Number Please Enter a Direct / Mobile Contact Number Text Code of Conduct Code of Conduct Question Description Code of Conduct على جميع الموردين الالتزام بمدونة مبادئ السلوك أثناء عملية إعداد وتقديم العروض والمقترحات أو أي إجراءات ذات علاقة مع البلدية وتعتبر جزء من الشروط العامة All suppliers must adhere to the Code of Conduct during the process of preparing and submitting offers and proposals or any procedures related to the municipality and are considered part of the general conditions. NDA NDA Question Description CONFIDENTIAL DISCLOSURE AGREEMENT (NDA) على جميع الموردين الالتزام بتوقيع نموذج عدم الإفشاء أثناء عملية إعداد وتقديم العروض مع البلدية وأرفاقه مع العرض المقدم وتعتبر جزء من الشروط العامة All suppliers are obligated to sign a non-disclosure Agreement (NDA) during the process of preparing and submitting offers with Dubai Municipality and attached with the submitted offer form part of the general conditions Tender Bond Tender Bond Question Description Tender Bond Form 2020 الضمان الابتدائي Performance Bank Guarantee Performance Bank Guarantee Question Description Performance Bank Guarantee Form 2020 الضمان النهائي Trade License Trade License Question Description Question Type Trade License Classification Please specify your Trade License type if its Local Option List Trade License Classification If No please specify Text SUSTAINABILITY SUSTAINABILITY Question Description Sustainable Policy سياسة الشراء المستدام Criteria to evaluate DM suppliers' commitment to apply sustainability معايير تقييم التزام موردي بلدية دبي بتطبيق الاستدامة Contact Details Contact Details Question Description Question Type Contact Person Name Please Enter Contact Person Name Text Contact Number Please Enter a Direct / Mobile Contact Number Text Code of Conduct Code of Conduct Question Description Code of Conduct على جميع الموردين الالتزام بمدونة مبادئ السلوك أثناء عملية إعداد وتقديم العروض والمقترحات أو أي إجراءات ذات علاقة مع البلدية وتعتبر جزء من الشروط العامة All suppliers must adhere to the Code of Conduct during the process of preparing and submitting offers and proposals or any procedures related to the municipality and are considered part of the general conditions. NDA NDA Question Description CONFIDENTIAL DISCLOSURE AGREEMENT (NDA) على جميع الموردين الالتزام بتوقيع نموذج عدم الإفشاء أثناء عملية إعداد وتقديم العروض مع البلدية وأرفاقه مع العرض المقدم وتعتبر جزء من الشروط العامة All suppliers are obligated to sign a non-disclosure Agreement (NDA) during the process of preparing and submitting offers with Dubai Municipality and attached with the submitted offer form part of the general conditions Tender Bond Tender Bond Question Description Tender Bond Form 2020 الضمان الابتدائي Performance Bank Guarantee Performance Bank Guarantee Question Description Performance Bank Guarantee Form 2020 الضمان النهائي Trade License Trade License Question Description Question Type Trade License Classification Please specify your Trade License type if its Local Option List Trade License Classification If No please specify Text SUSTAINABILITY SUSTAINABILITY Question Description Sustainable Policy سياسة الشراء المستدام Criteria to evaluate DM suppliers' commitment to apply sustainability معايير تقييم التزام موردي بلدية دبي بتطبيق الاستدامة Technical Envelope Technical Envelope General Attachments Allowed Technical Proposal Technical Proposal Question Description Question Type أهلية المقاول الرخصة التجارية تتضمن الأنشطة المرتبطة بنوع المشروع Attachment أهلية المقاول تقديم تقرير رواتب موظفي الشركة مصدق من وزارة العمل خلال آخر 6 أشهر(متوسط 90 فما فوق 5 نقاط ،80-90 3 نقاط أقل من 80 يستبعد ولايستكمل تقييمه) Attachment أهلية المقاول مؤهلات وخبرات مدير المشروع / مهندس مدني : ( خبرة 10 سنوات بنفس المجال ): بدون شهادات مهنية PMP (2نقطة) أو (3نقاط ) في حال وجود شهادة مهنية certified PMP (شريطة تقديم ما يثبت عمله في الشركة من : إقامة -بطاقة عمل ،مع تقديم تأكيد شهادات خبرة سابقة معتمدة داخل الدولة لمدة خمس سنوات ) Attachment أهلية المقاول مؤهلات وخبرات مهندس الميكانيك ( خبرة 10 سنوات بنفس المجال ): ( 3 نقطة )(شريطة تقديم ما يثبت عمله في الشركة من : إقامة -بطاقة عمل ،مع تقديم تأكيد شهادات خبرة سابقة معتمدة داخل الدولة لمدة خمس سنوات ) Attachment أهلية المقاول مؤهلات وخبرات مهندس الكهرباء ( خبرة 10 سنوات بنفس المجال ): ( 3 نقطة ) (شريطة تقديم ما يثبت عمله في الشركة من : إقامة -بطاقة عمل ،مع تقديم تأكيد شهادات خبرة سابقة معتمدة داخل الدولة لمدة خمس سنوات ) Attachment أهلية المقاول مؤهلات وخبرات حاسب كميات بدون شهادات مهنية PMP (0نقطة) أو (3نقاط ) في حال وجود شهادة مهنية certified PMP ( خبرة 10 سنوات بنفس المجال ): ( 3 نقطة )(شريطة تقديم ما يثبت عمله في الشركة من : إقامة -بطاقة عمل ،مع تقديم تأكيد شهادات خبرة سابقة معتمدة داخل الدولة لمدة خمس سنوات ) Attachment أداء المقاول الانطباع العام عن مدى التزام المقاول بمتطلبات التقديم وادراج الوثائق الداعمة ممتاز 5 درجات جيد جدا 3 درجات جيد 1 درجة Attachment أداء المقاول تطبيق المورد لمنظومة إدارية (جودة – صحة وسلامة – بيئة – غيرها) وفق متطلبات مواصفة دولية وحصوله على شهادة مطابقة معها (مثل مواصفات الأيزو أو المواصفات الأوروبية أو البريطانية) وجود شهادة مطابقة مع مواصفة دولية مجددة 3 درجات وجود شهادة مطابقة مع مواصفة دولية غير مجددة 2 درجتان عدم وجود شهادة مطابقة مع مواصفة دولية صفر Attachment أداء المقاول اثبات التعامل مع مصنعين محليين من إمارة دبي عن طريق المقاولة من الباطن Attachment أداء المقاول الشركات أعضاء مؤسسة محمد بن راشد لتنمية المشاريع الصغيرة والمتوسطة (SME) أو إثبات الدعم لأعضاء مؤسسة محمد بن راشد لتنمية المشاريع الصغيرة والمتوسطة (SME)عن طريق المقاولة من الباطن Attachment أداء المقاول متوسط تقييم المقاول لدى إدارة العقود والمشتريات 5 درجات اذا التقييم A 3 درجات اذا التقييم B 2 درجات اذا التقييم C 0 درجات اذا التقييم D 1 درجة اذا لا توجد مشاريع سابقة Attachment الوضع المالي للمقاول سجل الشركة المالي في حسن الأداء من خلال تقديم تقرير حسابات معتمد من مكتب حسابات معتمد في آخر 5 سنوات (لكل سنة درجة) Attachment الوضع المالي للمقاول تقييم شركة الاتحاد للتقييم الائتماني 4 درجات 746-900 3 درجات 711-745 2 درجات 651-710 يستبعد 541 - 650 يستبعد 541 ومادون Attachment الوضع المالي للمقاول متوسط حجم المشاريع السنوي خلال آخر 5 سنوات بالدرهم ملاحظة: يعتمد على موازنة المشروع قيد التقييم المتوسط≥ 300 مليون 5 درجات 200مليون ≤ المتوسط < 300 مليون 3 درجات 100مليون ≤ المتوسط < 200 مليون 2 درجتان المتوسط < 100 مليون 1 درجة Attachment خبرات المقاول الخبرات العامة (سنة تأسيس الشركة، المشاريع المنفذة أو قيد التنفيذ) 10 سنة 5 نقاط ، 5- 9 سنة 3 نقاط ، اقل من 5 سنة صفر Attachment خبرات المقاول الخبرات المتخصصة (تنفيذ مشروعين مشابهين من حيث الطبيعة الفنية للمشروع في آخر 5 سنوات) بأداء جيد مع تقديم شهادات الانجاز مشروعين 10 درجات مشروع 5 درجات Attachment خبرات المقاول الخبرات في إدارة الأمن والسلامة (إدارة الأمن والسلامة لمشروعين متشابهين) تحقيق متطلبات الاستدامة والبيئة والصحة والسلامة المهنية (تقديم شهادات ايزو صالحة 5 / 2.5علامات ، شهادة منتهية 3/1.5 ، عدم تقديم شهادة صفر) مشروعين 5 درجات مشروع 2.5 درجات Attachment منهجية العمل البرنامج الزمني Attachment منهجية العمل التدفق المالي الشهري Attachment منهجية العمل خطة إدارة العمالة Attachment منهجية العمل خطة إدارة المواد والتوريدات Attachment المعدات تقديم قائمة المعدات اللازمة لتنفيذ المشروع (ملك أو استئجار): مثل خلاطة خرسانة عدد 2 نقطتين، شيول عدد 3 ( 3 نقاط) ، بوبكات عدد 2 نقطتين Attachment Commercial Envelope Commercial Envelope General Attachments Allowed VAT Registration Details VAT Registration Details Question Description Question Type DM - Registration Number Kindly insert your DM Registration Number Text DM - VAT Registration Number Kindly insert your company VAT Registration Number Text DM - VAT Certificate Kindly upload a copy of your company VAT registration certificate Attachment DM - VAT Exempt Evidence If your company is exempted from VAT, kindly provide any evidence document Attachment Tender Bond Tender Bond Question Description Question Type Tender Bond Copy Please attach a copy of the Tender Bond here. Attachment Tender Bond Expiry Please insert the Tender Bond Expiry date here. Date Question Description Tender Bond Hard Copy يسلم أصل الشيك فقط في المبنى الرئيسي لبلدية دبي – الطابق الثالث مكتب رقم 321 وعلى المناقص تحميل نسخة من الضمان أو الشيك من خلال نظـــام التوريد الالكتروني لحكومة دبي قبل يوم واحد على الأقل من الموعد المحدد لإغلاق المناقصة Only the original Cheque shall be delivered to Finance department (3rd Floor, Office No.321) located at Dubai Municipality headquarters. In addition to that, bidders are required to upload the copy of Tender Bond/Cheque into eSupply System at least one day before closing date. Tender Bond amount قيمة ضمان المناقصة: مبلغ مقطوع كما هو محدد في دعوة العطاء Tender bond amount: lump sum amount as mentioned in invitation letter BILL No. 01 - PRELIMINARIES - Page No. 1.1 BILL No. 01 - PRELIMINARIES - Page No. 1.1 Code Description Note: GENERAL REQUIREMENTS Note: General Notes: Note: ● Any items required in General requierments and has no item in BOQ will be considered subsidiary and included in the prices of the other items). Note: ● Total amount of General requierments must be not Exceeding 5 % of the Total amount of financial offer,if the Bidder failure to comply/adhere to the mentioned percentage , Dubai Municipality will entitled to reject the offer. Note: Contractual Requirements Note: Performance Security Note: Note: DM will reimburse the CONTRACTOR for Performance Security fees at cost, supported by the surety’s invoice. For the avoidance of doubt, the amount specified in the Bill of Quantities is only indicative and shall not be paid to the Contractor. Note: The maximum amount for reimbursement of Performance Security fees shall not exceed the ceiling price, calculated as follows: Performance security amount = 0.3% x (number of quarters in contract period) x (bidder price) x 10% (performance security amount) Code Description Remarks Unit of Measurement Quantity A “Bidder is not required to price it ; the amount will be calculating automatically regarding to the equations in the Grand Summary and will be including in Bidder's total price , all conditions and requirements that mentioned in the Preamble will be applied.” Item 1 Code Description Note: Insurance of the Works Note: Note: DM will reimburse the CONTRACTOR for insurance of work fees at cost, supported by the invoice. For the avoidance of doubt, the amount specified in the Bill of Quantities is only indicative and shall not be paid to the Contractor. Note: The maximum amount for reimbursement of insurance of work fees shall not exceed the ceiling price and the ceiling price shall be equal to 0.15% of the bidder price. Code Description Remarks Unit of Measurement Quantity B “Bidder is not required to price it ; the amount will be calculating automatically regarding to the equations in the Grand Summary and will be including in Bidder's total price , all conditions and requirements that mentioned in the Preamble will be applied.” Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 01 - PRELIMINARIES - Page No. 1.2 BILL No. 01 - PRELIMINARIES - Page No. 1.2 Code Description Note: GENERAL REQUIREMENTS (Cont'd) Note: Contractual Requirements(Cont'd) Code Description Remarks Unit of Measurement Quantity A Third Party Liability Insurance Item 1 B Workmen's Compensation Insurance Item 1 Code Description Note: Specified Requirements Note: Accommodation for the Engineer's Staff Code Description Remarks Unit of Measurement Quantity C Establishment of offices Item 1 D Maintenance of offices Day 365 E Removal of offices Item 1 Code Description Note: Sundry Items Note: Testing of Materials Code Description Remarks Unit of Measurement Quantity F Arrange and carry out all specified tests and trails to materials including all necessary provision of samples for the following items all in accordance with Specification Item 1 G Set of monthly reports Month 12 H Co-ordinate with Service Authorities (DEWA, ETISALAT, RTA, DM Drainage & Irrigation Department, Building Dept. etc.) for obtaining and maintaining all NOCs, Building Permit, Green Building approvals etc. and pay all relevant fees Item 1 Code Description Note: As-Built drawings and Operations & Maintenance Manual Code Description Remarks Unit of Measurement Quantity J Allow for providing as-built drawings and operations & maintenance manualAllow for providing as-built drawings and operations & maintenance manual Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 01 - PRELIMINARIES - Page No. 1.3 BILL No. 01 - PRELIMINARIES - Page No. 1.3 Code Description Note: GENERAL REQUIREMENTS (Cont'd) Note: Temporary Works Note: Project Sign Board Code Description Remarks Unit of Measurement Quantity A Erection of Project Sign Board, as detailed Item 1 B Maintenance Days 365 C Removal Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - SITE WORK - Page No. 2.1 BILL No. 02 - SITE WORK - Page No. 2.1 Code Description Note: DIVISION 02 - SITE WORKS Note: Site Preparation Code Description Remarks Unit of Measurement Quantity A Site Clearance, including removal of rubbish, debris, vegetation, within the designated work area complete accordance with the specifications and drawings m2 1,688 Code Description Note: Excavation Note: Excavation from existing level to bottom of foundation levels complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Bulk Excavation m3 422 C Pit Excavation m3 708 D Trench Excavation m3 83 Code Description Note: Backfilling Code Description Remarks Unit of Measurement Quantity E Backfilling, including compaction in layer complete in accordance with specifications and drawings m3 453 Code Description Note: Disposal of Material Arising From Excavations Code Description Remarks Unit of Measurement Quantity F Remove surplus excavated material from site to approved location complete in accordance with specifications and drawings m3 760 Code Description Note: Road base Code Description Remarks Unit of Measurement Quantity G Road base, including compaction in layer complete in accordance with specifications and drawings m3 107 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - SITE WORK (CONT'D) - Page No. 2.2 BILL No. 02 - SITE WORK (CONT'D) - Page No. 2.2 Code Description Note: DIVISION 02 - SITE WORKS(CONT'D) Note: Anti - Termite Treatment Note: Allow for anti termite treatment under blinding and around building complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Laid horizontally m2 1,688 B Laid vertically m2 1,618 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - CONCRETE WORK - Page No. 3.1 BILL No. 02 - CONCRETE WORK - Page No. 3.1 Code Description Note: DIVISION 03 - CONCRETE WORKS Note: IN ACCORDANCE WITH SPECIFICATIONS AND DRAWINGS Note: Sub Structure Note: Plain concrete, C20/25 compressive strength with ordinary Portland cement, GGBS, including shuttering, additives, plasticizers, curing, vibrating, and all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A 100 mm thick Blinding m3 192 Code Description Note: Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating, and all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Foundation m3 145 C Neck column m3 14 D Wall below grade m3 2 E Slab on grade m3 193 F Ground beam m3 109 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - CONCRETE WORKS (Cont'd)- Page No. 3.2 BILL No. 02 - CONCRETE WORKS (Cont'd)- Page No. 3.2 Code Description Note: DIVISION 03 - CONCRETE WORKS ( CONT`D) Note: Sub Structure (Cont`d) Note: Steel reinforcement Note: High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420 N/mm2 for shear design complete in accordance with specification and drawing Code Description Remarks Unit of Measurement Quantity A 8 mm diameter kg 2 B 10 mm diameter kg 4,843 C 12 mm diameter kg 21,845 D 16 mm diameter kg 17,402 E 20 mm diameter kg 987 Code Description Note: Shuttering Note: Temporary shuttering, standard finish complete in accordance with specifications and drawing Code Description Remarks Unit of Measurement Quantity F To sides of foundation m2 260 G To sides of neck columns m2 148 H To sides of wall below grade m2 12 J To sides of ground beams m2 802 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - CONCRETE WORKS (Cont'd)- Page No. 3.3 BILL No. 02 - CONCRETE WORKS (Cont'd)- Page No. 3.3 Code Description Note: DIVISION 03 - CONCRETE WORKS ( CONT`D) Note: Super Structure Note: Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating, and all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Columns m3 49 B Walls m3 6 C Slabs m3 288 D Beams m3 32 E Drop panel m3 23 F Parapet m3 89 Code Description Note: Steel reinforcement Note: High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420 N/mm2 for shear design complete in accordance with specification and drawing Code Description Remarks Unit of Measurement Quantity G 8 mm diameter kg 7 H 10 mm diameter kg 9,505 J 12 mm diameter kg 48,482 K 16 mm diameter kg 10,859 L 20 mm diameter kg 3,187 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - CONCRETE WORKS (Cont'd)- Page No. 3.4 BILL No. 02 - CONCRETE WORKS (Cont'd)- Page No. 3.4 Code Description Note: DIVISION 03 - CONCRETE WORKS ( CONT`D) Note: Super Structure (Cont'd) Note: Shuttering Note: Temporary shuttering, standard finish complete in accordance with specifications and drawing Code Description Remarks Unit of Measurement Quantity A To sides of columns m2 535 B To sides of walls m2 43 C To sides and soffits of slabs m2 1,302 D To sides and soffits of drop panel m2 156 E To sides and soffits of beams m2 314 F To sides of parapet m2 890 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - CONCRETE WORKS (Cont'd)- Page No. 3.5 BILL No. 02 - CONCRETE WORKS (Cont'd)- Page No. 3.5 Code Description Note: CONCRETE SUNDRIES Code Description Remarks Unit of Measurement Quantity A Allow for all joints including isolation, control, construction and contraction joints or the like as required all in accordance with the specifications and drawings Item 1 B Allow for equipment base concrete as required all in accordance with the specifications and drawings Item 1 C Allow for concrete shaft cover as required all in accordance with the specifications and drawings Item 1 D Allow for structural opening for MEP services and networks throw slabs, beams, columns and foundations all in accordance with the specifications and drawings Item 1 E Allow for all builders work in connection with the whole of MEP works including all manholes, sumps, pits, etc. Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - MASONARY WORKS - Page No. 4.1 BILL No. 02 - MASONARY WORKS - Page No. 4.1 Code Description Note: DIVISION 04 - MASONRY WORKS Note: External Block Work Note: External thermo solid normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Ref.WB03, 200mm thick m2 31 Code Description Note: External CMU solid block normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Ref.WB01, 100mm thick m2 254.8 Code Description Note: External CMU hollow normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C Ref.WB04, 300mm thick m2 369.52 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - MASONARY WORKS - Page No. 4.2 BILL No. 02 - MASONARY WORKS - Page No. 4.2 Code Description Note: DIVISION 04 - MASONRY WORKS (CONT`D) Note: Internal Block Work Note: Internal hollow block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Ref.WB02, 150mm thick m2 44 Code Description Note: Thermo solid normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Ref.WB03, 200mm thick m2 1,650 C Ref.WB03*, 200mm thick , 1 H fire rated m2 121 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - MASONARY WORKS - Page No. 4.3 BILL No. 02 - MASONARY WORKS - Page No. 4.3 Code Description Note: DIVISION 04 - MASONRY WORKS (CONT`D) Note: Masonry Sundries Code Description Remarks Unit of Measurement Quantity A Allow for control joint complete in accordance with specification and drawing Item 1 B Allow for fire sealant complete in accordance with specification and drawing Item 1 C Allow for all opening and builder works for all MEP services in connection with masonry works all complete in accordance with specification and drawing Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - METAL WORK - Page No. 5.1 BILL No. 02 - METAL WORK - Page No. 5.1 Code Description Note: DIVISION 05 - METAL WORKS Note: Non Structural Metal Work Note: Ladders Note: Supply and install galvanized steel ladder including rungs, side rails, safety cage, frame, steel brackets, supports, anchors, bolts, fixing, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Ref. EF-07, Access cat ladder, 800x6010 mm height No 1 Code Description Note: Handrails and Balustrades Note: Supply and install stainless steel balustrade pipe hand rail, grade 316, including 30mm diameter stainless steel hand rail, 40mm diameter stainless steel top & bottom rails, base plate, fixing in position, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Ref.EF09, Stainless steel railing, 900mm high, for ramp m 40 Code Description Note: Aluminum Louver to MEP Equipment Area Note: Supply and install powder coated aluminium louver panels including aluminum frame and steel support, fixing in position, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C Ref.EF06, Aluminum louver panel, size 2000 x 950mm high No 2 D Ditto, size 2000 x 2550mm high No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - METAL WORK - Page No. 5.2 BILL No. 02 - METAL WORK - Page No. 5.2 Code Description Note: DIVISION 05 - METAL WORKS(CONT'D) Note: Stainless Steel Grating Note: Supply and install stainless tell grating including fixing in position, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A To Ablution, size-1500x550mm No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - WOOD WORKS - Page No. 6.1 BILL No. 02 - WOOD WORKS - Page No. 6.1 Code Description Note: DIVISION 06 - WOOD WORKS Note: Supply and install wood cabinat, including hard board back panels, shelves, hinges, back splash, skirting, counter top, drawers, ironmongery, fittings, accessories, fixing and all necessary works complete in accordance with specifications and drawings ( counter top measured elsewhere) Note: Base unit Code Description Remarks Unit of Measurement Quantity A Kitchen cabinat, size 3420x 600 x 900mm high No 1 Code Description Note: Wall unit Code Description Remarks Unit of Measurement Quantity B Kitchen cabinat, size 3420x 350 x 700mm high No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.1 BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.1 Code Description Note: DIVISION 07 - THERMAL & MOISTURE PROTECTION Note: Substructure Waterproofing Note: Supply and apply 1000guage polyethylene separation sheet, complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity A Laid horizontally, under slab on grade m2 1,288 Code Description Note: Supply and apply 1 layer of 4mm THK. each waterproofing membrane torch applied, complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity B Laid horizontally, under and above foundation m2 710 Code / Note Title Laid horizontally, under ground beam m2 201 D Laid vertically, side foundation m2 260 E Laid vertically, column neck and wall below grade m2 160 F Laid vertically, side ground beam m2 802 Code Description Note: Protection board Note: Supply and install seal tight protection board complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity G Laid vertically & horizontally, 6mm thick m2 1,570 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.2 BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.2 Code Description Note: DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D) Note: Wet Area Waterproofing System Note: Supply and apply SBS modified bitumen Jellfied emulion, 2 coats, to wet areas, including one coat primer with 20% water, surface preparation and all necessary works complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity A Laid Horizontally m2 116 B Laid Vertically, 150mm high m 210 Code Description Note: Supply and install 3mm heavy duty damp proof membrane including surface preparation and all necessary works complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity C Laid Horizontally m2 116 Code Description Note: Supply and apply Light weight concrete,70mm thk. density 500 to 700KG/m laid to slope including surface preparation and all necessary works complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity D Laid Horizontally m2 116 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.3 BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.3 Code Description Note: DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D) Note: Roof Waterproofing System Note: Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings Note: Laid Horizontally Code Description Remarks Unit of Measurement Quantity A Roof cement tiles, Size 300x300 m2 1,278 B Polyflex combo-top coat (1000 mic thick), sri > 78 as per green building regulation m2 1,278 C SBR bonding agent m2 1,278 D Concrete screed (26n/mm 2-350opc, 80mm ave. thickness) m2 1,278 E Polyfab filter membrane (1200mic thick) m2 1,278 F Polytex liquid U.V. protection coat ( 600mic thick) m2 1,278 G Polyurethane foam of thickness 110mm with 45-50kg/m 3density m2 1,278 H Light weight foam concrete, 50mm mni thickness. sloped to drain 2% m2 1,278 J Polybond bonding agent m2 1,278 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.4 BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.4 Code Description Note: DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D) Note: Roof Waterproofing System ( Cont`d) Note: Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings (Cont`d) Note: Laid Vertically Code Description Remarks Unit of Measurement Quantity A Brush applied polytex -hr top coat (1000mic thick) sri > 78 m 1,141 B Fabric reinforcement m 1,141 C Angle Fillet, 100x100mm m 1,141 D Polybond bonding agent m 1,141 E polyfab filter membrane (1200mic thick) m 1,141 F Polyurethane foam of thickness 110mm with 45-50kg/m 3density m 1,141 G Aluminum flashing m 1,141 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.5 BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.5 Code Description Note: DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D) Note: Sundries Code Description Remarks Unit of Measurement Quantity A Allow for waterproofing dressing around rain water outlet Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - DOORS & WINDOWS - Page No. 8.1 BILL No. 02 - DOORS & WINDOWS - Page No. 8.1 Code Description Note: DIVISION 08 - DOORS AND WINDOWS Note: External Doors Note: Metal Doors Note: Supply and install metal doors with powder coated finish including frame, ironmongeries, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity A Ref. MD-01, Double flush door, size 2000 x 2200mm high No 2 Code Description Note: Aluminium Doors Note: Supply and install aluminium doors with powder coated finish including frame, ironmongeries, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity B Ref. MD-02, Single flush door, size 1250 x 2200mm high No 1 Code Description Note: Internal Doors Note: Wooden Doors Note: Supply and install solid core doors, hinged flush including 18mm thick marine plywood subframe, 38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer, ironmongeries, architrave, decorations, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity C Ref. WD-02 ; Double leaf door size 1500 x 2200mm high, with concealed door closer No 2 D Ref. WD-02* ; Double leaf door size 1500 x 2200mm high, with concealed door closer, 45min fire rated No 2 E Ref. WD-07 ; single hinged door size 1250 x 2200mm high , 45 min fire rated No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - DOORS & WINDOWS - Page No. 8.2 BILL No. 02 - DOORS & WINDOWS - Page No. 8.2 Code Description Note: DIVISION 08 - DOORS AND WINDOWS(CONT'D) Note: Internal Doors ( Cont`d) Note: Wooden Doors ( Cont`d) Note: Supply and install solid core doors, hinged flush including 18mm thick marine plywood subframe, 38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer, brushed stainless steel kick plate, ironmongeries, architrave, decorations, fixing, fittings and all necessary works complete in accordance with specifications and drawings ( Cont`d) Code Description Remarks Unit of Measurement Quantity A Ref. WD-04 ; single hinged door size 1300 x 2200mm high, with concealed door closer No 2 Code Description Note: Supply and install solid core doors, hinged flush including 18mm thick marine plywood subframe, 38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer, 6mm thick clear fire rated glass ( as per CD requirement), brushed stainless steel kick plate, ironmongeries, architrave, decorations, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity B Ref. WD-06 ; single hinged door size 1300 x 2200mm high, with concealed door closer, No 2 C Ref. WD-06* ; single hinged door size 1300 x 2200mm high, , with concealed door closer, 45 min fire rated No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - DOORS & WINDOWS - Page No. 8.3 BILL No. 02 - DOORS & WINDOWS - Page No. 8.3 Code Description Note: DIVISION 08 - DOORS AND WINDOWS(CONT'D) Note: Internal Doors ( Cont`d) Note: Wooden Doors ( Cont`d) Note: Supply and install hinged flush wooden door including 18mm thick marine plywood subframe, 38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer, brushed stainless steel kick plate, ironmongeries, architrave, decorations, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity A Ref. WD-08 ; single hinged door size 1250 x 2200mm No 18 Code Description Note: Supply and install hinged flush wooden door including 18mm thick marine plywood subframe, 38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer, ironmongeries, architrave, decorations, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity B Ref. WD-03 ; single hinged door size 1300 x 2200mm high No 2 C Ref. WD-03* ; single hinged door size 1300 x 2200mm high , 45 min fire rated No 1 D Ref.WD-05 ; Single hinged size 1300 X 2200mm high No 19 E Ref. WD-05* ; single hinged door size 1300 x 2200mm high , 45 min fire rated No 12 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - DOORS & WINDOWS - Page No. 8.4 BILL No. 02 - DOORS & WINDOWS - Page No. 8.4 Code Description Note: DIVISION 08 - DOORS AND WINDOWS(CONT'D) Note: Internal Doors ( Cont`d) Note: Aluminium Doors Note: Supply and install aluminium doors with powder coated finish including frame, ironmongeries, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity A Ref. MD-03, Double flush door, size 1250 x 2200mm high No 2 Code Description Note: Windows Note: Supply and install glazed aluminum windows including powder coated aluminum frames, Ironmongery, fittings, fire rating, acoustic insulation and all necessary accessories complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Window, size 1600 x 1500mm No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - DOORS & WINDOWS - Page No. 8.5 BILL No. 02 - DOORS & WINDOWS - Page No. 8.5 Code Description Note: DIVISION 08 - DOORS AND WINDOWS(CONT'D) Note: Curtain Walls Note: Supply and install curtain wall system, 24mm thick double glazed, factory finished, comprising interior aluminum transom frames, aluminum mullions, double glazed, insulation, end mullions, aluminum sheet flashing and copping, caps, additional decorative frames, automatic/manual doors within curtain wall Note: with all accessories, U.V. resistant structural sealing compound, window, pre-filler, structural silicone, backing rod, gasketing, fire rating, hardware sets, all fitting and fixing accessories, complete as shown on detailed drawings and as per specifications. Code Description Remarks Unit of Measurement Quantity A REF; CW 01, size 2600mm x 4050mm including sliding door size 2025 x 4050mm No 1 B REF; CW 02, size 5400mm x 3350mm No 1 C REF; CW 03, size 2200mm x 3350mm including sliding door size 1325mm x 3350mm No 12 D Ref. CW04, size 1860mm x 3350mm, including single hinged door size 1050mm x 2475mm No 2 E REF; CW 05, size 6000mm x 3350mm No 1 F REF; CW 06, size 3400mm x 3350mm No 1 G REF; CW 07, size 2700mm x 3350mm including sliding door size 1325mm x 3350mm No 12 H REF; CW 08, size 4000mm x 3350mm No 1 J REF; CW 10, size 2510mm x 4050mm No 1 K REF; CW 12, size 4610mm x 3350mm No 4 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - DOORS & WINDOWS - Page No. 8.6 BILL No. 02 - DOORS & WINDOWS - Page No. 8.6 Code Description Note: DIVISION 08 - DOORS AND WINDOWS(CONT'D) Note: Curtain Walls (Cont`d) Note: Supply and install curtain wall system, 24mm thick double glazed, factory finished, comprising interior aluminum transom frames, aluminum mullions, double glazed, insulation, end mullions, aluminum sheet flashing and copping, caps, additional decorative frames, automatic/manual doors within curtain wall Note: with all accessories, U.V. resistant structural sealing compound, window, pre-filler, structural silicone, backing rod, gasketing, fire rating, hardware sets, all fitting and fixing accessories, complete as shown on detailed drawings and as per specifications (Cont`d) Code Description Remarks Unit of Measurement Quantity A REF; CW 13, size 5560 x3350mm, including double leaf sliding door size 2150 x 2195mm No 2 B Ref.CW14, size 2000mm x 3350mm, sliding No 2 C Ref. CW 15 ;size 1500 x 3350mm high No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - FINISHES - Page No. 9.1 BILL No. 02 - FINISHES - Page No. 9.1 Code Description Note: DIVISION 09 - FINISHES Note: Internal Finishes Note: Backgrounds Note: Floor Screed Note: Supply and install Cement and sand screed with self levelling compound; including sand filling, surface preparation, and all necessary works; complete all in according to drawings and specifications Code Description Remarks Unit of Measurement Quantity A To receive porcelain tiles m2 1,170 B To receive carpet flooring m2 36 C To receive epoxy paint m2 74 Code Description Note: Plaster Note: Supply and install 20mm thick cement and sand plaster to block or concrete walls and columns including metal lath and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity D To receive wall paint m2 2,359 E To receive wall tile m2 521 Code Description Note: Supply and install cement sand plaster to soffits including all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity F To receive paint finish m2 74 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - FINISHES - Page No. 9.2 BILL No. 02 - FINISHES - Page No. 9.2 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: Internal Finishes (Cont'd) Note: Internal Finishes Note: Floor Finishes Note: Supply and apply Heavy duty free solvent epoxy coating including all necessary works complete in accordance with specifications and drawings (Screed measured separately) Code Description Remarks Unit of Measurement Quantity A Ref-FF04 m2 74 Code Description Note: Supply and install porcelain tiles flooring including bedding materials, matching colored grout, polished, jointing floor transition strips and acoustic underlay (where required) and all necessary works complete in accordance with specifications and drawings (Screed measured separately) Code Description Remarks Unit of Measurement Quantity B Ref-FF01, porcelain tiles, Size 600x600mm m2 1,058 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - FINISHES - Page No. 9.3 BILL No. 02 - FINISHES - Page No. 9.3 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: Internal Finishes (Cont'd) Note: Floor Finishes (Cont'd) Note: Supply and install Unglazed non skid Porcelain tiles flooring including bedding materials, matching colored grout, polished, jointing floor transition strips and acoustic underlay (where required) and all necessary works complete in accordance with specifications and drawings (Screed measured separately) Code Description Remarks Unit of Measurement Quantity A Ref-FF02, porcelain tiles, Size 300x300mm m2 112 Code Description Note: Supply and install carpet roll on terrazzo tiles, including cushion, trim accessories, acoustical underlayment's, and all necessary works complete in accordance with specifications and drawings (Screed measured separately) Code Description Remarks Unit of Measurement Quantity B Ref-FF03, carpet roll on terrazzo tiles, 250x250x25mm m2 36 Code Description Note: Supply and install terrazzo tiles including grouting, jointing, control joint, bedding material and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity C Terrazzo tiles m2 36 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - FINISHES - Page No. 9.4 BILL No. 02 - FINISHES - Page No. 9.4 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: Internal Finishes (Cont'd) Note: Floor Finishes (Cont'd) Note: Threshold Note: Supply and install marble threshold including bedding materials, waterproofing, grouting, jointing and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A 200mm wide, 30mm thick m 69 B 300mm wide, 30mm thick m 97 Code Description Note: Skirting Note: Supply and install porcelain tile skirting including backing, jointing and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C Ref-Sk01, high heavy duty porcelain tiles skirting, 100mm m 602 Code Description Note: Walls Finishes Note: Supply and install porcelain wall tiling fixed with approved adhesive including backing, jointing, corner trim and all necessary works complete in accordance with specifications and drawings (Plaster measured separately) Code Description Remarks Unit of Measurement Quantity D Ref-WF-02, porcelain tiles, Size 300 x 600mm m2 450 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - FINISHES - Page No. 9.5 BILL No. 02 - FINISHES - Page No. 9.5 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: Internal Finishes (Cont'd) Note: Ceiling Finishes Note: Supply and install 12mm thick gypsum board ceiling including access panel, suspension system, light cove, supports, channels, shadow gap, clips, angles, fixing, fittings and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Ref-CL-01 m2 1,041 Code Description Note: Supply and install powder coated & anti bacteria aluminium tile ceiling including access panel, suspension system, supports, channels, clips, angles, fixing, fittings and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Ref-CL-02, Size 600 x 600mm m2 103 Code Description Note: Supply and install 12.5mm thick suspended gypsum board bulkhead including paint finish, suspension system, supports, fixing, fittings and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C Gypsum bulkhead, Ref. CL-01 , 400mm high m 83 D Gypsum bulkhead, Ref. CL-01 , 550mm high m 34.59 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - FINISHES - Page No. 9.6 BILL No. 02 - FINISHES - Page No. 9.6 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: Internal Finishes (Cont'd) Note: Painting and Decoration Note: Supply and install emulation high quality 100 % pure anti fungal & anti microbial (bacteria) highly washable paint , Matt finish, including backing, jointing, corner trim and all necessary works complete in accordance with specifications and drawings (Plaster measured separately) Code Description Remarks Unit of Measurement Quantity A Ref-WF-01, Emulation paint m2 2,104 Code Description Note: Supply and install emulation paint including all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Ref-CL-03 m2 74 Code Description Note: Supply and apply paint finish including surface preparation, primer coat, final coat and all necessary works complete in accordance with specifications and drawings (Plaster measured separately) Code Description Remarks Unit of Measurement Quantity C To gypsum board ceiling, paint Ref-CL-01 m2 1,041 D To powder coated aluminum and anti bacteria ceiling tiles , Ref-CL-02 m2 103 E T o bulk heads m2 45.625 Code Description Note: Supply and install anti-fungal paint including all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity F To walls, above false ceiling wet areas m2 255.97 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - FINISHES - Page No. 9.7 BILL No. 02 - FINISHES - Page No. 9.7 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: External Finishes Note: Backgrounds Note: Floor Screed Note: Supply and install Cement and sand screed with self levelling compound; including sand filling, surface preparation, and all necessary works; complete all in according to drawings and specifications Code Description Remarks Unit of Measurement Quantity A To receive porcelain tiles m2 70 Code Description Note: Plaster Note: Supply and install cement and sand plaster to block or concrete walls and columns including metal lath and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B To external block or concrete walls and columns, to receive paint finish m2 1,190 C To parapet , 20mm thick m2 426 Code Description Note: Floor Finishes Note: Supply and install porcelain tiles flooring including bedding materials, matching colored grout, polished, jointing floor transition strips and acoustic underlay (where required) and all necessary works complete in accordance with specifications and drawings (screed measured separately) Code Description Remarks Unit of Measurement Quantity D Ref-FF01, porcelain tiles, Size 600x600 , main entrance m2 18.2 E Ref-FF01, porcelain tiles, Size 600x600 , for ramp m2 52 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - FINISHES - Page No. 9.8 BILL No. 02 - FINISHES - Page No. 9.8 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: External Finishes ( Cont`d) Note: Painting and Decoration Note: Supply and apply paint finish including surface preparation, primer coat, final coat and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A To plastered walls, Ref. EF 01 m2 1,190 B To parapet walls & top, Ref. EF 01 m2 384 Code Description Note: GRG Panels Note: Supply and install of GRG wall panels, CNC with paint, including steel frame, base plates, anchor bolts, support and fixing, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C Ref; EF-02 , size 1100 X 3950mm No 6 D Ref; EF-02 , size 2100 X 3950mm No 10 E Ref; EF-02 , overall size 3300 X 3950mm, L-shaped No 3 F Ref; EF-02 , overall size 4200 X 3950mm, L-shaped No 1 G Ref; EF-02 , overall size 4400 X 3950mm, , L-shaped No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - FINISHES - Page No. 9.9 BILL No. 02 - FINISHES - Page No. 9.9 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: External Finishes ( Cont`d) Note: GRG Canopy Note: Supply and install of GRG canopy, CNC with paint, including steel frame, base plates, anchor bolts, support and fixing, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A REF, EF02 size 2500 X 1700 mm No 1 B REF, EF02 size 4400 X 4490 mm No 1 C REF, EF02 size 2000 X 3000 mm No 6 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ACCESSORIES - Page No. 10.1 BILL No. 02 - ACCESSORIES - Page No. 10.1 Code Description Note: DIVISION 10 - ACCESSORIES Note: Sanitary Fixture & Accessories Note: Supply and install sanitary fixtures and accessories including fittings, fixings, connections and all necessary works complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity A Ref. STB003, security clothing hook welded to 5 mm thk clothing hook welded to 5mm thick steel plate. No 5 B Ref. TB008, foam soap No 22 C Ref. BD001, Hand spray bidet No 18 D Ref. TB007, Free-standing Pedal Bin With removable insert and Softclose No 18 E Ref. LAV001, wash basin No 18 F Ref. SH-001, Wall-mounted shower set with mixer, handheld shower, and adjustable rail No 9 G Ref. STB001, Toilet paper holder, stain steel recessed No 18 H Ref. STB005, Mediclinics steel paper No 12 J Ref. TB004, Medicare Grab rail for wall mountain No 2 K Ref. TB005, Medicare grab rail for wall mounting, for barrier-free requirements, stainless steel No 6 L Ref. TB006, Grab bar manufactured by Mediclinics in steel bar Ø 32 mm vertical No 2 M Ref. FD 03; floor drain No 22 N Ref. WC-002; Wall-Hung Vitreous China Water Closet with Concealed tank Connection No 18 P Ref.FC-001; Single-lever basin mixer tap No 17 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ACCESSORIES - Page No. 10.2 BILL No. 02 - ACCESSORIES - Page No. 10.2 Code Description Note: DIVISION 10 - ACCESSORIES(CONT'D) Note: Sanitary Fixture & Accessories(Cont'd) Note: Supply and install sanitary fixtures and accessories including fittings, fixings, connections and all necessary works complete in accordance with the specifications and drawings(cont'd) Code Description Remarks Unit of Measurement Quantity A Ref.FD 01; 800mm Stainless Steel Linear Shower Drain (AXOR Finish Set) No 9 B Ref. FB001, Wall-Mounted Dual Flush Actuator Plate for Concealed Cistern No 9 C Circular wash basin No 2 D Wash basin No 2 Code Description Note: Mirrors Note: Supply and install mirror fixed on and including backing, frame, beveled edge and groove; all in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity E Ref. TB-002, Size 600x900x8mm thick No 4 Code Description Note: Vanity Counters Note: Supply and install vanity counters including fascia panel, splash back, supports, cut-out for wash basin, fittings, fixing, accessories, sealant and all necessary works complete in accordance with the specifications and drawings (wash basin measured elsewhere) Code Description Remarks Unit of Measurement Quantity F Size 1500 x 600 x 250 mm with 1 No, cut basin , drop fascia 380mm No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ACCESSORIES - Page No. 10.3 BILL No. 02 - ACCESSORIES - Page No. 10.3 Code Description Note: DIVISION 10 - ACCESSORIES(CONT'D) Note: Counters Note: Supply and install counters including support, side finish, top finish, fittings, fixing, accessories, sealant and all necessary works complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity A To kitchen cabinet at male wing common area size 3420x 600 No 1 Code Description Note: Glass partitions Note: Supply and install glass partitions including doors, hardware, fixings, forming, openings, all fittings and accessories complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Ref.GLZ-01; size 1900 x 3350mm, including single hinged door size 1000 x 2200mm No 1 C Ref; PAR-05 , Glass partition 800 x 2000mm high No 9 D Ref. PAR-06, Glass partition size 2710mm x 2200mm including single hinged door size 1000mm x 2200 mm No 2 E Ref. PAR-01, Size 2700mm x 2200mm No 1 F Ref. PAR-06, Glass partition size 2750mm x 2200mm No 1 G Ref. PAR-02, size 3220 x 3000mm high including single hinged door size 1000 x 2200 mm H No 2 H Ref. PAR-03, Glass partition size 3620 x 2200mm high including single hinged door size 1000 x 2200 mm No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ACCESSORIES - Page No. 10.4 BILL No. 02 - ACCESSORIES - Page No. 10.4 Code Description Note: DIVISION 10 - ACCESSORIES(CONT'D) Note: Ablution Seats Note: Supply and install ablution seat including marble top, 20mm thick, ceramic tiles on mortar beds, reinforcement concrete, waterproofing, fixing, accessories, sealant and all necessary works complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity A Ablution Seat Item 1 Code Description Note: Signage Code Description Remarks Unit of Measurement Quantity B Supply and install signage including all fittings, fixings, support, accessories and all in accordance with specifications and drawings Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - FURNISHINGS - Page No. 12.1 BILL No. 02 - FURNISHINGS - Page No. 12.1 Code Description Note: DIVISION 12 - FURNISHINGS Note: Loose Furnitures Note: Supply and install furniture including fittings, fixing, hardware, accessories and all related works, complete in accordance with drawings and specifications Code Description Remarks Unit of Measurement Quantity A Ref. BD-01, Single Wooden Bedroom (1.00x2.20)m No 9 B Ref. BD-02, Clinic Bedroom (1.00x2.00)m No 1 C Ref. BT-01, Wooden Comod 400x400mm No 3 D Ref. CF-LCA-01, Base cabinet with laminate doors, solid-surface countertop, and drop-in sink No 1 E Ref. CF-UCA-01, Wall-mounted upper kitchen cabinet with hinged laminae doors No 1 F Ref. CH-01, Chair high bacl wooden leg No 8 G Ref. CH-02, Wooden office chair (0.65x0.65)m No 9 H Ref. CH-04, Wooden Chair with high long back leg No 17 J Ref. CH-05, Wooden table for four chair No 12 K Ref. CH-06, Ergonomic swivel office chair with armrests and headset No 38 L Ref. CP-01, Carpet (4x3)m No 2 M Ref. DSK-01, Wooden office desk (1.75x0.75)m No 9 N Ref. DSK-02, Wooden office chair (2.5x0.75)m No 1 P Ref. DT-02, Wooden table for four chair No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - FURNISHINGS - Page No. 12.2 BILL No. 02 - FURNISHINGS - Page No. 12.2 Code Description Note: DIVISION 12 - FURNISHINGS (Cont'd) Note: Loose Furnitures (Cont'd) Note: Supply and install furniture including fittings, fixing, hardware, accessories and all related works, complete in accordance with drawings and specifications. (Cont'd) Code Description Remarks Unit of Measurement Quantity A Ref. F-B01, Double bed 1800x2100mm No 1 B Ref. F-B02, Bed Side (0.40x0.40)m No 7 C Ref. F-TB02, Wooden stand stable with glass No 7 D Ref. SF-01, Sofa for Reception area (2.40x1.00)m No 2 E Ref. SF-03, Reception wooden table (1.00x0.55)m No 1 F Ref. TB-01, Wooden stand stable with glass No 8 G Ref. TB-02, Wooden bedroom table (1.50x.50)m No 9 H Ref. TB-03, Wooden stand stable with glass No 2 J Ref. TB-04, meeting room table for 6 person No 1 K Ref. TB-06, Wooden office for staff room No 8 L Ref. TB-07, Sofa (1.85x0.75) m No 3 M Ref. TV-01, TV Reception area No 2 N Ref. TV-TB-01, Reception counter (1.40x0.501)m No 2 P Ref. WR-01, Deskdrawer for bedroom (2.30x0.55)m No 8 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION - Page No. 15.1 BILL No. 02 -MECH INSTALLATION - Page No. 15.1 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS Note: Rainwater, soil, waste, and vent pipework installations complete in accordance with specifications and drawings Note: Pipework Note: above ground uPVC pipework including fittings, accessories, insect screen, and all necessary works complete in accordance with drawings and specifications Code Description Remarks Unit of Measurement Quantity A 82mm diameter m 34 B 110mm diameter m 80 Code Description Note: Under ground uPVC pipework including excavation, backfilling, warning tap, fittings, accessories, and all necessary works complete in accordance with drawings and specifications Code Description Remarks Unit of Measurement Quantity C 50mm diameter m 115 D 82mm diameter m 33 E 110mm diameter m 215 Code Description Note: Fittings, complete in accordance with drawings and specifications Note: Rain Water Drain Code Description Remarks Unit of Measurement Quantity F Ref. RWO, 110mm diameter No 16 Code Description Note: Floor Drain Code Description Remarks Unit of Measurement Quantity G Ref. FD, 150x150mm No 25 Code Description Note: Floor Cleanout Code Description Remarks Unit of Measurement Quantity H Ref. FCO 110mm diameter No 25 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.2 BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.2 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Vent Cowl Code Description Remarks Unit of Measurement Quantity A Size 110mm No 2 B Size 82mm No 8 Code Description Note: Grating Cover Code Description Remarks Unit of Measurement Quantity C Grating cover, size 1500x500mm No 2 D Grating cover, size 2000x500mm No 2 E Shower Grating, size 800x70mm No 9 Code Description Note: Domestic Hot and Cold Water Installation Note: Cold Water Supply System Note: Supply and install cold water PPR pipe works including necessary, fittings, valves and accessories, and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity F 20mm diameter m 496 G 25mm diameter m 41 H 32mm diameter m 17 J 32mm diameter, circulation pipe m 8 K 40mm diameter m 37 L 40mm diameter, water transfer line m 9 M 50mm diameter m 44 N 65mm diameter m 5 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.3 BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.3 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Domestic Hot and Cold Water Installation Note: Hot & Return Water Supply System Note: Supply and install hot water PPR pipe works with insulation including necessary, fittings, valves and accessories, and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A 20mm diameter m 430 B 25mm diameter m 37 C 32mm diameter m 17 D 40mm diameter m 19 Code Description Note: Pumps Note: Supply, install test and commission water pumps set with control panels, fittings, supports, flexible connections, electrical works, vibration isolation, electronic pressure controller, pressure gauges, protections and all required components and accessories as per drawings and specifications Code Description Remarks Unit of Measurement Quantity E Domestic water booster pump set, flow 1.60 L/S, head 2.50 Bar, (1 Duty, 1 Standby). No 2 F Domestic water circulation pump set, flow 1.60 L/S, head 2.50 Bar, (1 Duty, 1 Standby). No 2 Code Description Note: Hot Water Pump Code Description Remarks Unit of Measurement Quantity G Hot water return pump set, capacity 1.60 L/s @ 2.50 Bar head, (1 Duty, 1 Standby) No 2 Code Description Note: Pressure Vessel Code Description Remarks Unit of Measurement Quantity H Pressure vessel 100 liters No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.4 BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.4 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Domestic Hot and Cold Water Installation (Cont'd) Note: Demotic Water Tank Note: GRP hot pressed panel type, sectional insulated water tank including connections, float valve, pipes, access panel, fitting, accessories and valves and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A Size 4.0 x 2.50 x 1.50 m, capacity 15.0 m3 No 1 Code Description Note: Solar System Note: Supply, install, test and commission flat plate solar system. Including collectors, tanks, short pipes, vent, valves, complete with all fittings, supports and all required accessories as per drawings & specifications. Code Description Remarks Unit of Measurement Quantity B Flat plate solar system, (3 Collectors) No 1 Code Description Note: UV Sterilization Unit Note: Supply, install test and commission UV Sterilization complete with all required components and accessories as per drawings and specifications Code Description Remarks Unit of Measurement Quantity C UV sterilization unit, 1.6 L/s No 1 Code Description Note: Domestic Cooler Unit Note: Supply, install test and commission domestic cooler unit complete with valves, fittings, supports, electrical works, and all required components and accessories as per drawings and specifications Code Description Remarks Unit of Measurement Quantity D Cooler unit, cooling capacity 10.5kw No 1 Code Description Note: Estidama Water Meter Code Description Remarks Unit of Measurement Quantity E Estidama water meter, ref EWM-01 No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.5 BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.5 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Domestic Hot and Cold Water Installation (Cont'd) Note: Isolating Valves Code Description Remarks Unit of Measurement Quantity A 15mm diameter No 4 B 20mm diameter No 53 C 25mm diameter No 3 D 32mm diameter No 7 E 40mm diameter No 1 F 50mm diameter No 4 G 65mm diameter No 1 Code Description Note: Bib Tap Code Description Remarks Unit of Measurement Quantity H 15mm diameter No 4 Code Description Note: Ball Valves Code Description Remarks Unit of Measurement Quantity J 20mm diameter No 17 Code Description Note: Gate Valves Code Description Remarks Unit of Measurement Quantity K 25mm diameter No 3 L 40mm diameter No 3 Code Description Note: Water Hammer Arrestor Code Description Remarks Unit of Measurement Quantity M 20mm diameter No 38 Code Description Note: Mixing valve Code Description Remarks Unit of Measurement Quantity N Thermostatic mixing valve setting temperature @ 46.0C, 32mm diameter No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.6 BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.6 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Fire Fighting System Note: Supply and install black steel fire fighting water pipe works including drain pipes, fittings, accessories valve and supports and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A 25mm diameter m 413 B 25mm diameter, drain pipe m 1 C 32mm diameter m 19 D 40mm diameter m 29 E 50mm diameter m 27 F 65mm diameter m 18 G 65mm diameter, wet riser pipe m 27 H 80mm diameter m 35 J 80mm diameter, wet riser pipe m 17 K 100mm diameter m 7 L 150mm diameter m 31 Code Description Note: Fire Hose Cabinet Note: Supply, install, test and commission hose station consist of a 25 mm hose reel & a 65 mm diameter landing valve including but not limited to cabinets, reels, fire extinguishers, isolating valves, pressure regulating valves, pressure reducing valves hoses, nozzles, marking, fixings, supports and all required components and accessories as per drawings, specifications and civil defense regulations. Code Description Remarks Unit of Measurement Quantity M Ref FHC No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.7 BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.7 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Fire Fighting System (Cont'd) Note: Frie Extinguisher Note: Supply install test and commission fire extinguisher including but not limited to wall fixing frame and hanger and all required components and accessories as per drawings, specifications and civil defense regulations. Code Description Remarks Unit of Measurement Quantity A 5 Kg dry CO2 fire extinguisher No 4 B 4.5 Kg dry powder fire extinguisher No 2 C FFP foam trolly type 33 gal. No 1 Code Description Note: Fire Blanket Note: Supply and fix fire blanket including all accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity D Fire Blanket, ref FB No 1 Code Description Note: Automatic Air Vent Note: Supply and install automatic air vent including all accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity E Automatic air vent ref AAV, 150mm No 1 Code Description Note: Sprinkler Heads Note: Supply and install Sprinkler Heads including all fittings and accessories complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity F Pendant sprinkler head No 139 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.8 BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.8 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Fire Fighting System (Cont'd) Note: Valves and other fittings complete in accordance with specification and drawings Note: Zone Control Valve Code Description Remarks Unit of Measurement Quantity A ZCV, 150mm No 1 Code Description Note: Pressure Reducing Valve Code Description Remarks Unit of Measurement Quantity B PRV, 150mm No 1 Code Description Note: Non-Return Valve Code Description Remarks Unit of Measurement Quantity C NRV, 150mm No 1 Code Description Note: Breeching Inlet Code Description Remarks Unit of Measurement Quantity D 150mm dia X 4 Way breeching inlet for sprinkler and wet riser systems No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.9 BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.9 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation Note: Ductwork Note: Design, fabrication and installation of galvanized sheet metal ductwork including circular duct work, supports, fittings and accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A Supply duct Kg 3,524 B Return duct Kg 846 C Fresh duct Kg 568 D Exhaust duct Kg 412 E Toilet extract duct Kg 837 F Flexible supply air duct 200mm diameter m 17 Code Description Note: Internal Duct Insulation Note: Supply and install internal insulation for duct and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity G For supply duct m2 612 H For return duct m2 83 J Toilet extract duct m2 77 Code Description Note: External Duct Insulation Note: Supply and install insulation for external duct with aluminum cladding and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity K Supply duct m2 42 L Return duct m2 41 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.10 BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.10 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation (Cont'd) Note: External Duct Insulation (Cont'd) Note: Supply and install external insulation for duct and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A For fresh duct m2 109 B For exhaust duct m2 84 C Toilet extract duct m2 107 Code Description Note: Fresh Air Handling Unit Note: Supply and install fresh air handling units including connections to the ducts, controls, anti vibration mountings, thermostat, smoke detectors, sensors, filters, coil, protective devices and drain and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity D FAHU-01, air flow rate 1382 L/s, cooling capacity 11.53 kw No 1 Code Description Note: Condensate Unit Note: Supply and install condensate unit including connections to the pipes, controls, anti vibration mountings, thermostat, smoke detectors, sensors, filters, coil, protective devices and drain and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity E CU/01-FAHU-01 No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.11 BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.11 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation(Cont'd) Note: Package Units Note: Supply, install, test and commission package unit, including but not limited to insulation, electrical and control wiring, cables, thermostats, control devices, supports, fittings, vibration isolation and all required components and accessories as per drawings, specifications and according to manufacturers requirements. Code Description Remarks Unit of Measurement Quantity A Ref. 01-PU-01, flow rate 3932 L/s No 1 B Ref. 01-PU-02, flow rate 2327 L/s No 1 C Ref. 01-PU-03, flow rate 2198 L/s No 1 D Ref. 01-PU-04, flow rate 2836 L/s No 1 E Ref. 01-PU-05, flow rate 2327 L/s No 1 Code Description Note: Fans Note: Supply and install fans including connections, fittings, back draft, and accessories and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity F Ref. 01-EXF-01, flow rate 600 L/s No 2 Code Description Note: Sound Attenuator Code Description Remarks Unit of Measurement Quantity G Sound attenuator ref. SA, size 900x500mm No 1 H Sound attenuator ref. SA, size 900x600mm No 1 J Sound attenuator ref. SA, size 950x500mm No 2 K Sound attenuator ref. SA, size 950x700mm No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.12 BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.12 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation(Cont'd) Note: Variable & Constant Air Volume System Note: Supply and install VAV/CAV box including connections, fittings, and accessories and all necessary works complete in accordance with specification and drawings Note: Variable Air Volume Code Description Remarks Unit of Measurement Quantity A Ref. 01-VAV-01, flow rate 239 L/s No 1 B Ref. 01-VAV-02, flow rate 218 L/s No 1 C Ref. 01-VAV-03, flow rate 207 L/s No 1 D Ref. 01-VAV-04, flow rate 207 L/s No 1 E Ref. 01-VAV-05, flow rate 352 L/s No 1 F Ref. 01-VAV-06, flow rate 268 L/s No 1 G Ref. 01-VAV-07, flow rate 289 L/s No 1 H Ref. 01-VAV-08, flow rate 160 L/s No 1 J Ref. 01-VAV-09, flow rate 136 L/s No 1 K Ref. 01-VAV-10, flow rate 136 L/s No 1 L Ref. 01-VAV-11, flow rate 136 L/s No 1 M Ref. 01-VAV-12, flow rate 130 L/s No 1 N Ref. 01-VAV-13, flow rate 61 L/s No 1 P Ref. 01-VAV-14, flow rate 197 L/s No 1 Q Ref. 01-VAV-15, flow rate 61 L/s No 1 R Ref. 01-VAV-16, flow rate 123 L/s No 1 S Ref. 01-VAV-17, flow rate 136 L/s No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.13 BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.13 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation (Cont'd) Note: Variable & Constant Air Volume System (Cont'd) Note: Variable Air Volume (Cont'd) Code Description Remarks Unit of Measurement Quantity A Ref. 01-VAV-18, flow rate 141 L/s No 1 B Ref. 01-VAV-19, flow rate 141 L/s No 1 C Ref. 01-VAV-20, flow rate 158 L/s No 1 D Ref. 01-VAV-21, flow rate 297 L/s No 1 E Ref. 01-VAV-22, flow rate 269 L/s No 2 F Ref. 01-VAV-23, flow rate 312 L/s No 1 G Ref. 01-VAV-24, flow rate 107 L/s No 1 H Ref. 01-VAV-25, flow rate 107 L/s No 1 J Ref. 01-VAV-26, flow rate 111 L/s No 1 K Ref. 01-VAV-27, flow rate 120 L/s No 1 L Ref. 01-VAV-28, flow rate 212 L/s No 1 M Ref. 01-VAV-29, flow rate 40 L/s No 1 N Ref. 01-VAV-30, flow rate 38 L/s No 1 P Ref. 01-VAV-31, flow rate 87 L/s No 1 Q Ref. 01-VAV-32, flow rate 87 L/s No 1 R Ref. 01-VAV-33, flow rate 128 L/s No 1 S Ref. 01-VAV-34, flow rate 512 L/s No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.14 BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.14 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation(Cont'd) Note: Variable & Constant Air Volume System (Cont'd) Note: Constant Air Volume Code Description Remarks Unit of Measurement Quantity A Ref. 01-CAV-01, flow rate 86 L/s No 1 B Ref. 01-CAV-04, flow rate 113 L/s No 1 C Ref. 01-CAV-03, flow rate 138 L/s No 1 D Ref. 01-CAV-02, flow rate 38 L/s No 1 E Ref. 01-CAV-05, flow rate 36 L/s No 1 F Ref. 01-CAV-06, flow rate 60 L/s No 1 G Ref. 01-CAV-07, flow rate 145 L/s No 1 H Ref. 01-CAV-08, flow rate 35 L/s No 1 J Ref. 01-CAV-09, flow rate 454 L/s No 2 K Ref. 01-CAV-10, flow rate 140 L/s No 1 Code Description Note: DX Unit Note: Supply, install, test and commission DX unit cooling only including but not limited to indoor & outdoor units, vibration isolation, control wiring, flexible connectors, integral control, hanger, supports, filters, sleeves, condensate piping and all required accessories as per drawings and specifications. Code Description Remarks Unit of Measurement Quantity L Ref. 01-SP-01 / CU/01-SP-01, air side 2700 L/s No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.15 BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.15 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation(Cont'd) Note: Dampers Note: Supply and install damper including connections, fittings and accessories and all necessary works complete in accordance with specification and drawings Note: Volume Control Damper Code Description Remarks Unit of Measurement Quantity A Volume control damper ref. VCD size 100x100mm No 2 B Ditto ref. VCD size 150x100mm No 20 C Ditto ref. VCD size 150x150mm No 4 D Ditto ref. VCD size 200x150mm No 5 E Ditto ref. VCD size 200x200mm No 1 F Ditto ref. VCD size 250x150mm No 7 G Ditto ref. VCD size 250x200mm No 4 H Ditto ref. VCD size 250x250mm No 1 J Ditto ref. VCD size 300x200mm No 7 K Ditto ref. VCD size 350x150mm No 1 L Ditto ref. VCD size 350x200mm No 7 M Ditto ref. VCD size 350x250mm No 2 N Ditto ref. VCD size 400x200mm No 1 P Ditto ref. VCD size 400x250mm No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.16 BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.16 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation(Cont'd) Note: Dampers (Cont'd) Note: Volume Control Damper (Cont'd) Code Description Remarks Unit of Measurement Quantity A Volume control damper ref. VCD size 450x200mm No 1 B Ditto ref. VCD size 450x250mm No 1 C Ditto ref. VCD size 500x300mm No 1 D Ditto ref. VCD size 600x300mm No 1 E Ditto ref. VCD size 600x500mm No 6 F Ditto ref. VCD size 700x350mm No 1 G Ditto ref. VCD size 750x400mm No 1 H Ditto ref. VCD size 800x550mm No 1 J Ditto ref. VCD size 200mm diameter No 37 Code Description Note: Fire Damper Code Description Remarks Unit of Measurement Quantity K Fire damper ref. FD, size 150x100mm No 4 L Ditto ref. FD, size 200x150mm No 1 M Ditto ref. FD, size 250x150mm No 7 N Ditto ref. FD, size 250x200mm No 1 P Ditto ref. FD, size 350x250mm No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.17 BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.17 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation(Cont'd) Note: Dampers (Cont'd) Note: Fire Damper (Cont'd) Code Description Remarks Unit of Measurement Quantity A Fire damper ref. FD, size 600x500mm No 3 B Ditto ref. FD, size 700x350mm No 1 C Ditto ref. FD, size 750x400mm No 1 Code Description Note: Motorized Damper Code Description Remarks Unit of Measurement Quantity D Motorized damper ref. MD, size 200x150mm No 1 E Ditto ref. MD, size 250x150mm No 1 F Ditto ref. MD, size 300x200mm No 1 G Ditto ref. MD, size 350x150mm No 2 H Ditto ref. MD, size 350x200mm No 2 J Ditto ref. MD, size 350x250mm No 1 K Ditto ref. MD, size 450x200mm No 1 L Ditto ref. MD, size 450x250mm No 1 M Ditto ref. MD, size 450x350mm (NC) No 1 N Ditto ref. MD, size 450x350mm (NO) No 1 P Ditto ref. MD, size 700x400mm No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.18 BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.18 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation(Cont'd) Note: Diffusers, Grills, Dampers, Liner diffusers Note: Supply and return air slot diffuser with integrated opposed blades volume damper and with adjustable deflection blades with 25mm thick acoustic one plenum box. Code Description Remarks Unit of Measurement Quantity A Ref. SLD, 1000mm length, 1-slot No 26 B Ref. SLD, 1000mm length, 2-slots No 11 C Ref. RLD, 1000mm length, 1-slot No 26 D Ref. RLD, 1000mm length, 2-slots No 11 Code Description Note: Supply and return air diffuser Code Description Remarks Unit of Measurement Quantity E Ref. SD 150x100mm No 6 F Ref. SD 150x150mm No 3 G Ref. SD 225x225mm No 27 H Ref. SD 300x300mm No 16 J Ref. RD 150x100mm No 6 K Ref. RD 150x150mm No 3 L Ref. RD 225x225mm No 27 M Ref. RD 300x300mm No 16 Code Description Note: Disk Valve Code Description Remarks Unit of Measurement Quantity N Ref. DV 150mm diameter No 20 Code Description Note: Exhaust Diffuser Code Description Remarks Unit of Measurement Quantity P Ref. EAD 150x150mm No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.19 BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.19 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation(Cont'd) Note: Diffusers, Grills, Dampers, Liner diffusers(Cont'd) Note: Round supply and return air diffuser with adjustable butter fly control dampers(CONT'D) Note: Supply Grille Code Description Remarks Unit of Measurement Quantity A Ref. SG 150x100mm No 2 B Ref. SG 200x150mm No 1 C Ref. SG 250x150mm No 3 D Ref. SG 300x200mm No 1 Code Description Note: Return Grille Code Description Remarks Unit of Measurement Quantity E Ref. RG 150x100mm No 2 F Ref. RG 200x150mm No 1 G Ref. RG 250x150mm No 3 H Ref. RG 300x200mm No 1 Code Description Note: Exhaust Air Louver Code Description Remarks Unit of Measurement Quantity J EAL, with bird screen, 1245 L/s, face area 1.1m2 No 1 K EAL, with bird screen, 575 L/s, face area 0.51m2 No 1 Code Description Note: Fresh Air Louver Code Description Remarks Unit of Measurement Quantity L FAL, with sand trap and insect screen, 1382 L/s, face area 1.5m2 No 1 Code Description Note: Building Management System (BMS) Code Description Remarks Unit of Measurement Quantity M Supply, install, test and commissioning of Building management system including points, wires, conduits, and all necessary works complete in accordance with specifications and drawings Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.20 BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.20 Code Description Note: Sundry / General Items Code Description Remarks Unit of Measurement Quantity A Allow for permits, connection and inspection fees associated with mechanical installations by utility and statutory authorities Item 1 B Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings Item 1 C Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment Item 1 D Allow for setting out the works, marking positions of holes, mortises, chases or the like Item 1 E Allow for testing and commissioning and submission of test certificates Item 1 F Allow for all identification labels, plates, charts and identification of plant, equipment, cable, isolators and the like Item 1 G Allow for preparing schedule of manufacturers recommended tools and spare parts for each piece of equipment Item 1 H Allow for the provision of operating/maintenance manuals Item 1 J Allow for providing shop and coordination drawings Item 1 K Allow for domestic water piping, sterilization and disinfections after commissioning Item 1 L Allow for flushing chilled water system pipe work with water and establishment of rust inhibitor before commissioning Item 1 M Allow for fire stopping in accordance with the drawings, specification and local authorities requirements Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1 BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS Note: Power System installations Note: Automatic Transfer Switch (ATS) Note: Supply and install automatic transfer switch including fixing, fittings, terminations, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A ATS 63A No 1 Code Description Note: Generator Note: Supply, install, test, commission and maintain, prime rated generator including, but not limited to, lubrication system, control panels, fuel system and all associated devices and equipment, earthing, and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Standby diesel generator 24KW/30KVA No 1 Code Description Note: Main &Sub Main Distribution Boards Note: Supply, install, test, commission, and maintain main and sub-main distribution boards and terminations, including bus bars, breakers, indicators, meters, all interconnecting cables, wires termination, energy monitoring meters, and trays from the main board, and all necessary works complete in accordance with specification and drawings Note: Main Distribution Boards Code Description Remarks Unit of Measurement Quantity C Main distribution boards, ref MDB-ELD No 1 D Ditto, ref MDB-ELD-AC No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2 BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Power System Installations (Cont'd) Note: Main &Sub Main Distribution Boards (Cont'd) Note: Supply, install, test, commission, and maintain main and sub-main distribution boards and terminations, including bus bars, breakers, indicators, meters, all interconnecting cables, wires termination, energy monitoring meters, and trays from the main board, and all necessary works complete in accordance with specification and drawings Note: Sub Main Distribution Boards Code Description Remarks Unit of Measurement Quantity A Sub main distribution boards, ref ESMDB-ELD No 1 Code Description Note: Final Distribution Boards Note: Supply, install, test, commission and maintain Final Distribution boards and terminations including bus bars, breakers, indicators, all interconnecting cables, wires termination and trays from main board, and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Final distribution boards, DB-P1 No 1 C Ditto, ref DB-P2 No 1 D Ditto, ref DB-P3 No 1 E Ditto, ref DB-L1 No 1 F Ditto, ref EDB-L1 No 1 G Lighting control panel, ref LCP No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3 BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Cable Tray Note: Supply and install Cable trunk including fixing, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A 200x100mm cable trunk m 681 B 100x50mm cable trunk with cover m 71 C 300x50mm cable trunk with cover m 17 D 600x100mm cable trunk with cover m 36 Code Description Note: Cables Note: Low Voltage cables including ducts, glands, connections, conduits, termination, trays and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity E 2C.6 mm2 XLPE/SWA/PVC +1C.6 mm2 PVC/ECC/CU m 155 F 2C.6mm2 fire rated XLPE/SWA/PVC +1C.6 mm2 fire rated PVC/ECC/CU m 60 G 4C.10 mm2 XLPE/SWA/PVC +1C.10 mm2 PVC/ECC/CU m 189 H 4C.10 mm2 fire rated XLPE/SWA/PVC +1C.10 mm2 fire rated PVC/ECC/CU m 25 J 4C.16mm2 XLPE/SWA/PVC +1C.16 mm2 PVC/ECC/CU m 55 K 4C.16 mm2 fire rated XLPE/SWA/PVC +1C.16 mm2 fire rated PVC/ECC/CU m 12 L 4C.25mm2 XLPE/SWA/PVC +1C.16 mm2 PVC/ECC/CU m 213 M 4C.25 mm2 fire rated XLPE/SWA/PVC +1C.16 mm2 fire rated PVC/ECC/CU m 9 N 4C.50mm2 XLPE/SWA/PVC +1C.25 mm2 PVC/ECC/CU m 10 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4 BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Power Distribution Note: Supply and install the following power fittings including all necessary accessories and connections to wiring and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A 13A Single switched socket No 56 B 13A Twin switched socket No 49 C 13A Twin switched socket inside floor box No 31 D 15A Switched socket No 1 E 15A Switched socket inside floor box No 3 F 13A Switched spur outlet No 45 G 13A Unswitched spur outlet No 19 H 20A double pole switch No 17 Code Description Note: Power point Note: Supply and install wiring and conduit in concealed installation including cable trays / trucking, access box with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity J Power points No 221 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5 BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Power System Installations (Cont'd) Note: Floor Boxes Note: Supply, and install, floor boxes, including fixing, fitting, with all necessary works complete all in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity A Floor box with one compartment No 3 B Floor box with two compartments No 31 Code Description Note: Isolating Switch Note: Supply and install isolating switch including all interconnecting and terminations and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity C Isolator single phase 32A No 2 D Isolator single phase 32A IP65 No 3 E Isolator three phase 32A IP65 No 5 F Isolator three phase 40A No 1 G Isolator three phase 40A IP65 No 1 H Isolator three phase 63A IP65 No 5 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6 BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Power System Installations (Cont'd) Note: Internal Lighting Note: Supply and install lighting including all necessary accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Lighting fixture, type S1 No 46 B Ditto, type S2 No 28 C Ditto, type S3 No 18 D Ditto, type S4 No 89 E Ditto, type S5 No 29 F Ditto, type S6 No 23 G Ditto, type S7 No 13 H Ditto, type S8 No 1 J Ditto, type W1 No 10 K Ditto, type L1 No 15 Code Description Note: Internal Lighting Points Note: Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity L Internal Lighting points No 272 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.7 BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.7 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Power System Installations (Cont'd) Note: Switches Note: Supply, install, test, commission switches including all necessary accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A One gang, one way lighting switch 20A No 8 B One gang, one way lighting switch 20A, W/P No 3 C Two gang, one way lighting switch 20A No 15 D Three gang, two way lighting switch 20A No 18 E One gang, one way override switch 20A No 1 F Two gang, one way override switch 20A No 19 G One gang, two way override switch 20A No 6 H Two gang, two way override switch 20A No 6 J Three gang, two way override switch 20A No 2 K Lux and absence multi sensor No 12 L Presence sensor No 24 M Motion sensor No 24 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.8 BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.8 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Power System Installations (Cont'd) Note: Switches (Cont'd) Note: Supply, install, test, commission switches including all necessary accessories and all necessary works complete in accordance with specifications and drawings Note: Lighting switch Point Note: Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A Lighting switch points No 78 B Sensors points No 60 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.9 BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.9 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Emergency and Exit Lighting System Note: Supply, install, test, commission the following emergency and exit light fittings, including ceiling rose, heat resistance, flexible cable, lamps, electronic control gear, suspensions, connections to permanent wiring system in accordance with Specification and drawings Code Description Remarks Unit of Measurement Quantity A Self-contained 1x8w emergency light with built-in battery (3h duration ), surface-mounted, non-maintained No 5 B Self-contained 1x8w emergency light with built-in battery (3h duration ), recessed mounted, non-maintained No 36 C Self-contained 1x8w exit light maintained with a built-in battery (3h duration ) No 13 D Self-contained 1x8w exit light double-sided, maintained with a built-in battery (3h duration ) No 4 Code Description Note: Emergency lighting points Note: Supply and install wiring and conduit in concealed installation including cable trays / trunking, with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity E Emergency lighting points No 58 Code Description Note: Central Battery System Note: Supply and install central battery system including , pull boxes, junction boxes, wires, and connections to relevant panel complete as shown on drawings and as per specifications Code Description Remarks Unit of Measurement Quantity F Emergency light monitoring panel, ref EMP-ELD No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.10 BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.10 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Fire Alarm System Note: Supply, install, test, commission and maintain the complete Analogue addressable fire Alarm & evacuation system including cabling, wiring conduit, cable tray, trunking, termination and power connections and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Intelligent optical smoke detector and standard base No 53 B Smoke detector above ceiling void area No 54 C Intelligent heat detector with standard base No 2 D Intelligent optical smoke detector with sounder base No 9 E Manual call point No 5 F Fire alarm sounder with flasher No 4 G Fire alarm sounder or horn, W/P No 6 H Voice evacuation, ceiling mounted speaker No 20 J Desk type microphone for emergency voice broadcast No 5 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.11 BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.11 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Fire Alarm System (Cont'd) Note: Disabled Alarm System Note: Supply, install, test, commission and maintain the complete Analogue addressable Disabled Alarm System including cabling, wiring conduit, cable tray, trunking, termination and power connections and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Reset point No 2 B Over light door & sounder unit above the door with WC sticker No 2 C disabled toilet alarm pull cord No 2 D standalone alarm controller & power supply No 2 Code Description Note: Supply, install, test, commission fire alarm control panel with charger and batteries, power supply, fire fighter two way communication, amplifiers, voice evac., alarm system, AUX. output, PC monitor and control, software, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity E Fire alarm and voice evacuation integrated control panel, ref FACP-ELD, two loops No 1 F 24/7 DCD monitoring panel No 1 G Voice evacuation control system, VECP-ELD No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.12 BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.12 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Telecommunication System Note: Supply, install, test, commission complete telecommunication system, including cabling, wiring, conduits, cables, terminations and power connections and all necessary works complete all in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Voice outlet (RJ45) wall mounted No 18 B Data outlet for wireless access point outlet ceiling based No 9 C Single data outlet (RJ45) wall mounted for IPTV No 10 D Dual (RJ45) data&voice socket outlet wall mounted No 25 E Dual data outlet inside floor box No 31 F Telephone outlet inside floor box No 31 Code Description Note: Communications Equipment Note: Supply and install of data and communication equipment and racks; including all kinds of cable, wires, cable trays, and all required components, internal connections, all necessary support, fixings and accessories; and all necessary works complete all in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity G 42U telephone rack No 1 H Proposed server rack at main server room No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.13 BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.13 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: CCTV System Note: Supply install, test and commission complete CCTV system including rack, monitors, controllers , cabling, wiring, conduit and power connections, and all necessary works complete all in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A IP based identification dome camera No 6 B IP based recognition dome camera No 23 C IP based wall mounted weather proof bullet camera detection level No 13 D Future IP dome camera containment includes conduit and CAT6A cable No 23 E Provision for camera No 12 Code Description Note: CCTV Work Station Note: Supply and install CCTV works station, including, computer, screens, printers, and all necessary works complete all in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity F CCTV work stations No 2 Code Description Note: Security Equipment Note: Supply and install of data and security equipment and racks; including all kinds of cable, wires, cable trays, and all required components, internal connections, all necessary support, fixings and accessories; and all necessary works complete all in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity G Security rack 24U, ref MDF-SC-ELD No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.14 BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.14 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Access Control System Note: Supply install, test and commission complete access control system including cabling, cable tray, wiring, conduit and power connections, and all necessary works complete all in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Master door control panel No 1 B Door control panel No 11 C Door contact No 23 D Electric mortise lock No 15 E Electro magnetic lock No 7 F Card reader No 17 G Exit push button No 16 H Break glass unit No 16 Code Description Note: Cable Tray Note: Supply and install Cable trays including fixing, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity J 150x50mm HDGI cable tray for GSM m 110 K 200x50mm HDGI cable tray for ICT m 110 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.15 BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.15 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Earthing protection system Note: Supply, install, test and commissioning of earthing protection system including earth pits, conductors, bars ,bonds and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Earthing protection Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.16 BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.16 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Sundry / General Items Code Description Remarks Unit of Measurement Quantity A Allow for permits, connection and inspection fees associated with electrical installations by utility and statutory authorities Item 1 B Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings Item 1 C Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment Item 1 D Allow for setting out the works, marking positions of holes, mortises, chases or the like Item 1 E Allow for testing and commissioning and production of test certificates Item 1 F Allow for all identification labels, plates, charts and identification of plant, equipment, cable, switches and the like Item 1 G Allow for the provision of operating / maintenance manuals Item 1 H Allow for providing shop and coordination drawings Item 1 J Allow for instructing selected employer's personnel on all aspects of the operation of systems and equipment Item 1 K Supply and handover to the client all tools and equipment in accordance with the specification Item 1 L Allow for fire stopping in accordance with the drawings specification and local authorities requirements Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - SITE WORK - Page No. 2.1 BILL NO. 03 - SITE WORK - Page No. 2.1 Code Description Note: DIVISION 02 - SITE WORKS Note: Site Preparation Code Description Remarks Unit of Measurement Quantity A Site Clearance, including removal of rubbish, debris, vegetation, within the designated work area complete accordance with the specifications and drawings m2 1,748 Code Description Note: Excavation Note: Excavation from existing level to bottom of foundation levels complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Bulk Excavation m3 437 C Pit Excavation m3 628 D Trench Excavation m3 62 Code Description Note: Backfilling Code Description Remarks Unit of Measurement Quantity E Backfilling, including compaction in layer complete in accordance with specifications and drawings m3 366 Code Description Note: Disposal of Material Arising From Excavations Code Description Remarks Unit of Measurement Quantity F Remove surplus excavated material from site to approved location complete in accordance with specifications and drawings m3 761 Code Description Note: Road base Code Description Remarks Unit of Measurement Quantity G Road base, including compaction in layer complete in accordance with specifications and drawings m3 95 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - SITE WORK (CONT'D) - Page No. 2.2 BILL NO. 03 - SITE WORK (CONT'D) - Page No. 2.2 Code Description Note: DIVISION 02 - SITE WORKS(CONT'D) Note: Anti - Termite Treatment Note: Allow for anti termite treatment under blinding and around building complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Laid horizontally m2 1,748 B Laid vertically m2 1,485 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - CONCRETE WORK - Page No. 3.1 BILL NO. 03 - CONCRETE WORK - Page No. 3.1 Code Description Note: DIVISION 03 - CONCRETE WORKS Note: IN ACCORDANCE WITH SPECIFICATIONS AND DRAWINGS Note: Sub Structure Note: Plain concrete, C20/25 compressive strength with ordinary Portland cement, GGBS, including shuttering, additives, plasticizers, curing, vibrating, and all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A 100 mm thick Blinding m3 201 Code Description Note: Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating, and all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Foundation m3 128 C Neck column m3 12 D Wall below grade m3 1 E Slab on grade m3 217 F Ground beam m3 106 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - CONCRETE WORKS (Cont'd)- Page No. 3.2 BILL NO. 03 - CONCRETE WORKS (Cont'd)- Page No. 3.2 Code Description Note: DIVISION 03 - CONCRETE WORKS ( CONT`D) Note: Sub Structure (Cont`d) Note: Steel reinforcement Note: High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420 N/mm2 for shear design complete in accordance with specification and drawing Code Description Remarks Unit of Measurement Quantity A 8 mm diameter kg 1 B 10 mm diameter kg 4,685 C 12 mm diameter kg 25,735 D 16 mm diameter kg 14,121 E 20 mm diameter kg 2,421 Code Description Note: Shuttering Note: Temporary shuttering, standard finish complete in accordance with specifications and drawing Code Description Remarks Unit of Measurement Quantity F To sides of foundation m2 230 G To sides of neck columns m2 137 H To sides of wall below grade m2 4 J To sides of ground beams m2 793 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - CONCRETE WORKS (Cont'd)- Page No. 3.3 BILL NO. 03 - CONCRETE WORKS (Cont'd)- Page No. 3.3 Code Description Note: DIVISION 03 - CONCRETE WORKS ( CONT`D) Note: Super Structure Note: Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating, and all necessary works, complete in accordance with specifications and drawings (Cont'd) Code Description Remarks Unit of Measurement Quantity A Columns m3 45 B Walls m3 2 C Slabs m3 403 D Beams m3 25 E Drop panel m3 27 F Parapet m3 50 Code Description Note: Steel reinforcement Note: High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420 N/mm2 for shear design complete in accordance with specification and drawing Code Description Remarks Unit of Measurement Quantity G 8 mm diameter kg 2 H 10 mm diameter kg 15,059 J 12 mm diameter kg 51,132 K 16 mm diameter kg 9,650 L 20 mm diameter kg 2,945 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - CONCRETE WORKS (Cont'd)- Page No. 3.4 BILL NO. 03 - CONCRETE WORKS (Cont'd)- Page No. 3.4 Code Description Note: DIVISION 03 - CONCRETE WORKS ( CONT`D) Note: Super Structure (Cont'd) Note: Shuttering Note: Temporary shuttering, standard finish complete in accordance with specifications and drawing Code Description Remarks Unit of Measurement Quantity A To sides of columns m2 489 B To sides of walls m2 14 C To sides and soffits of slabs m2 1,476 D To sides and soffits of drop panel m2 184 E To sides and soffits of beams m2 253 F To sides of parapet m2 500 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - CONCRETE WORKS (Cont'd)- Page No. 3.5 BILL NO. 03 - CONCRETE WORKS (Cont'd)- Page No. 3.5 Code Description Note: DIVISION 03 - CONCRETE WORKS ( CONT`D) A CONCRETE SUNDRIES Code Description Remarks Unit of Measurement Quantity B Allow for all joints including isolation, control, construction and contraction joints or the like as required all in accordance with the specifications and drawings Item 1 C Allow for equipment base concrete as required all in accordance with the specifications and drawings Item 1 D Allow for concrete shaft cover as required all in accordance with the specifications and drawings Item 1 D Allow for structural opening for MEP services and networks throw slabs, beams, columns and foundations all in accordance with the specifications and drawings Item 1 E Allow for all builders work in connection with the whole of MEP works including all manholes, sumps, pits, etc. Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - MASONARY WORKS - Page No. 4.1 BILL NO. 03 - MASONARY WORKS - Page No. 4.1 Code Description Note: DIVISION 04 - MASONRY WORKS Note: External Block Work Note: External CMU hollow normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Ref.W-04, 300mm thick m2 367 Code Description Note: External CMU solid block normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Ref.W-01, cavity Block 100mm thick including 60mm polystyrene insulation m2 164 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - MASONARY WORKS - Page No. 4.2 BILL NO. 03 - MASONARY WORKS - Page No. 4.2 Code Description Note: DIVISION 04 - MASONRY WORKS (CONT`D) Note: Internal Block Work Note: Internal hollow block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Ref.W-02, 150mm thick m2 109 Code Description Note: Thermo solid normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Ref.W-03, 200mm thick m2 1,314 C Ref.W-03*, 200mm thick, 1hr fire rated m2 270 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - MASONARY WORKS - Page No. 4.3 BILL NO. 03 - MASONARY WORKS - Page No. 4.3 Code Description Note: DIVISION 04 - MASONRY WORKS (CONT`D) Note: Masonry Sundries Code Description Remarks Unit of Measurement Quantity A Allow for control joint complete in accordance with specification and drawing Item 1 B Allow for fire sealant complete in accordance with specification and drawing Item 1 C Allow for all opening and builder works for all MEP services in connection with masonry works all complete in accordance with specification and drawing Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - METAL WORK - Page No. 5.1 BILL NO. 03 - METAL WORK - Page No. 5.1 Code Description Note: DIVISION 05 - METAL WORKS Note: Non Structural Metal Work Note: Ladders Note: Supply and install galvanized steel ladder including rungs, side rails, safety cage, frame, steel brackets, supports, anchors, bolts, fixing, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Ref. EF-10, Access cat ladder, 800 mm diameter x 5640 mm height No 1 Code Description Note: Handrails and Balustrades Note: Supply and install stainless steel balustrade pipe hand rail, grade 316, including 30mm diameter stainless steel hand rail, 40mm diameter stainless steel top & bottom rails, base plate, fixing in position, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B 900mm high, for entrance ramp and step m 102 Code Description Note: Stainless Steel Grating Note: Supply and install stainless tell grating including fixing in position, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C To Ablution, size-1800x200mm No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - METAL WORK - Page No. 5.2 BILL NO. 03 - METAL WORK - Page No. 5.2 Code Description Note: DIVISION 05 - METAL WORKS (CONT'D) Note: Non Structural Metal Work Note: Aluminum Powder Coated Cladding Note: Supply and install Aluminium powder coated cladding including frame, support, fixing in position, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Ref EF-07, 280x4000mm No 1 B Ref EF-07, 5360x1050mm No 1 Code Description Note: Aluminum Louvers Note: Supply and install aluminum louvers decorative powder coated aluminum screens, decorative powder coated aluminum frame and steel support including all fittings, accessories and fixings complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C Ref. EF-08, Aluminum louvers, size 1600mm x 3350mm No 1 D Ditto, size 2000mm x 3350mm No 1 E Ditto, size 2010mm x 600mm No 2 Code Description Note: Supply and install powder coated aluminium louver panels including aluminum frame and steel support, fixing in position, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity F Aluminum louver Panels, ref. EF-06, size 1000mm x 5200mm No 3 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - METAL WORK - Page No. 5.3 BILL NO. 03 - METAL WORK - Page No. 5.3 Code Description Note: DIVISION 05 - METAL WORKS (CONT'D) Note: Non Structural Metal Work (Cont'd) Note: Aluminium Powder Coated Canopy Note: Supply and install Aluminium powder coated canopy, including steel box, galvanized beams supportive system, finishes, all fittings, accessories and fixings complete in accordance with specifications and drawings (Design by specialist) Code Description Remarks Unit of Measurement Quantity A Aluminium Canopy, size 1828x1810mm No 1 B Aluminium Canopy, size 9470x1510mm No 1 C Aluminium Canopy, L shaped size 7080x650mm No 1 D Aluminium Canopy, L shaped size 7520x1650mm No 1 E Aluminium Canopy, L shaped size 7430x1650mm No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - WOOD WORKS - Page No. 6.1 BILL NO. 03 - WOOD WORKS - Page No. 6.1 Code Description Note: DIVISION 06 - WOOD WORKS Note: Cabinets Note: Supply and install wood cabinet, including hard board back panels, shelves, hinges, back splash, skirting, counter top, drawers, ironmongery, fittings, accessories, fixing and all necessary works complete in accordance with specifications and drawings ( counter top measured elsewhere) Note: Base unit Code Description Remarks Unit of Measurement Quantity A Base cabinet, size 3400x600x900mm high No 3 B L-shaped pantry cabinet, size 5000x600x900mm high No 1 Code Description Note: Wall unit Code Description Remarks Unit of Measurement Quantity C Wall cabinet, size 3400x 350 x 700mm high No 1 D L-shaped wall unit, size 5000x350x700mm high No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.1 BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.1 Code Description Note: DIVISION 07 - THERMAL & MOISTURE PROTECTION Note: Substructure Waterproofing Note: Supply and apply 1000guage polyethylene separation sheet, complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity A Laid horizontally, under slab on grade m2 1,443 Code Description Note: Supply and apply 1 layer of 4mm THK. each waterproofing membrane torch applied, complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity B Laid horizontally, under and above foundation m2 629 Code / Note Title Laid horizontally, under ground beam m2 195 D Laid vertically, side foundation m2 230 E Laid vertically, column neck and wall below grade m2 141 F Laid vertically, side ground beam m2 793 Code Description Note: Protection board Note: Supply and install seal tight protection board complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity G Laid vertically & horizontally, 6mm thick m2 1,473 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.2 BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.2 Code Description Note: DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D) Note: Wet Area Waterproofing System Note: Supply and apply SBS modified bitumen Jellified emulsion, 2 coats, to wet areas, including one coat primer with 20% water, surface preparation and all necessary works complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity A Laid Horizontally m2 117 B Laid Vertically, 150mm high m 203 Code Description Note: Supply and install 3mm heavy duty damp proof membrane including surface preparation and all necessary works complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity C Laid Horizontally m2 112 Code Description Note: Supply and apply Light weight concrete,70mm thk. density 500 to 700KG/m laid to slope including surface preparation and all necessary works complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity D Laid Horizontally m2 112 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.3 BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.3 Code Description Note: DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D) Note: Roof Waterproofing System Note: Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings Note: Laid Horizontally Code Description Remarks Unit of Measurement Quantity A Roof cement tiles, Size 300x300 m2 1,560 B Polyflex combo-top coat (1000 mic thick), sri > 78 as per green building regulation m2 1,560 C SBR bonding agent m2 1,560 D Concrete screed (26n/mm 2-350opc, 80mm ave. thickness) m2 1,560 E Polyfab filter membrane ( 1200mic thick) m2 1,560 F Polytex liquid U.V. protection coat ( 600mic thick) m2 1,560 G Polyurethane foam of thickness 110mm with 45-50kg/m 3density m2 1,560 H Light weight foam concrete, 50mm mni thickness. sloped to drain 2% m2 1,560 J Polybond bonding agent m2 1,560 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.4 BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.4 Code Description Note: DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D) Note: Roof Waterproofing System ( Cont`d) Note: Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings (Cont`d) Note: Laid Vertically Code Description Remarks Unit of Measurement Quantity A Brush applied polytex -hr top coat ( 1000mic thick) sri > 78 m 286 B Fabric reinforcement m 286 C Angle Fillet, 100x100mm m 286 D Polybond bonding agent m 286 E polyfab filter membrane ( 1200mic thick) m 286 F Polyurethane foam of thickness 110mm with 45-50kg/m 3density m 286 G Aluminum flashing m 286 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.5 BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.5 Code Description Note: DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D) Note: Sundries Code Description Remarks Unit of Measurement Quantity A Allow for waterproofing dressing around rain water outlet Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - DOORS & WINDOWS - Page No. 8.1 BILL NO. 03 - DOORS & WINDOWS - Page No. 8.1 Code Description Note: DIVISION 08 - DOORS AND WINDOWS Note: External Doors Note: Metal Doors Note: Supply and install metal doors with powder coated finish including frame, ironmongeries, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity A Ref. MD-01, Double flush door, size 2000 x 2200mm high No 1 Code Description Note: Aluminium Doors Note: Supply and install aluminium doors with powder coated finish including frame, ironmongeries, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity B Ref. MD-02, Single flush door, size 1250 x 2200mm high No 1 Code Description Note: Internal Doors Note: Wooden Doors Note: Supply and install solid core doors, hinged flush including 18mm thick marine plywood subframe, 38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer, ironmongeries, architrave, decorations, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity C Ref. WD-01 ; Double leaf door size 2000 x 2200mm high, with concealed door closer No 1 D Ref. WD-02 ; Double leaf door size 1500 x 2200mm high, with concealed door closer No 7 E Ref. WD-07 ; single hinged door size 1250 x 2200mm high , 45 min fire rated No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - DOORS & WINDOWS - Page No. 8.2 BILL NO. 03 - DOORS & WINDOWS - Page No. 8.2 Code Description Note: DIVISION 08 - DOORS AND WINDOWS(CONT'D) Note: Internal Doors ( Cont`d) Note: Wooden Doors ( Cont`d) Note: Supply and install solid core doors, hinged flush including 18mm thick marine plywood subframe, 38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer, brushed stainless steel kick plate, ironmongeries, architrave, decorations, fixing, fittings and all necessary works complete in accordance with specifications and drawings ( Cont`d) Code Description Remarks Unit of Measurement Quantity A Ref. WD-04 ; single hinged door size 1300 x 2200mm high, with concealed door closer No 12 Code Description Note: Supply and install solid core doors, hinged flush including 18mm thick marine plywood subframe, 38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer, 6mm thick clear fire rated glass ( as per CD requirement), brushed stainless steel kick plate, ironmongeries, architrave, decorations, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity B Ref. WD-06 ; single hinged door size 1300 x 2200mm high, with concealed door closer, No 2 C Ref. WD-06* ; single hinged door size 1300 x 2200mm high, , with concealed door closer, 45 min fire rated No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - DOORS & WINDOWS - Page No. 8.3 BILL NO. 03 - DOORS & WINDOWS - Page No. 8.3 Code Description Note: DIVISION 08 - DOORS AND WINDOWS(CONT'D) Note: Internal Doors ( Cont`d) Note: Wooden Doors ( Cont`d) Note: Supply and install hinged flush wooden door including 18mm thick marine plywood subframe, 38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer, brushed stainless steel kick plate, ironmongeries, architrave, decorations, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity A Ref. WD-08 ; single hinged door size 1250 x 2200mm high No 6 Code Description Note: Supply and install hinged flush wooden door including 18mm thick marine plywood subframe, 38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer, ironmongeries, architrave, decorations, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity B Ref. WD-03 ; single hinged door size 1300 x 2200mm high No 7 C Ref. WD-03* ; single hinged door size 1300 x 2200mm high , 45 min fire rated No 3 D Ref.WD-05 ; Single hinged size 1300 X 2200mm high No 21 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - DOORS & WINDOWS - Page No. 8.4 BILL NO. 03 - DOORS & WINDOWS - Page No. 8.4 Code Description Note: DIVISION 08 - DOORS AND WINDOWS(CONT'D) Note: Internal Doors ( Cont`d) Note: Aluminium Doors Note: Supply and install aluminium doors with powder coated finish including frame, ironmongeries, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity A Ref. MD-03, Double flush door, size 1250 x 2200mm high No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - DOORS & WINDOWS - Page No. 8.5 BILL NO. 03 - DOORS & WINDOWS - Page No. 8.5 Code Description Note: DIVISION 08 - DOORS AND WINDOWS(CONT'D) Note: Curtain Walls Note: Supply and install curtain wall system, 24mm thick double glazed, factory finished, comprising interior aluminum transom frames, aluminum mullions, double glazed, insulation, end mullions, aluminum sheet flashing and copping, caps, additional decorative frames, automatic/manual doors within curtain wall Note: with all accessories, U.V. resistant structural sealing compound, window, pre-filler, structural silicone, backing rod, gasketing, fire rating, hardware sets, all fitting and fixing accessories, complete as shown on detailed drawings and as per specifications. Code Description Remarks Unit of Measurement Quantity A REF; CW 01, size 2600mm x 4000mm including sliding door size 2025 x 4050mm No 1 B REF; CW 02, size 5400mm x 3350mm No 1 C REF; CW 03, size 2200mm x 3350mm including sliding door size 1325mm x 3350mm No 12 D Ref. CW04, size 1860mm x 3350mm, including single hinged door size 1050mm x 2475mm No 2 E REF; CW 05, size 6000mm x 3350mm No 1 F REF; CW 06, size 3400mm x 3350mm No 3 G REF; CW 07, size 2700mm x 3350mm including sliding door size 1325mm x 3350mm No 6 H REF; CW 08, size 4000mm x 3350mm No 2 J Ref. CW 09, size 2700x3350mm No 2 K REF; CW 10, size 2510mm x 4050mm No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - DOORS & WINDOWS - Page No. 8.6 BILL NO. 03 - DOORS & WINDOWS - Page No. 8.6 Code Description Note: DIVISION 08 - DOORS AND WINDOWS(CONT'D) Note: Curtain Walls (Cont`d) Note: Supply and install curtain wall system, 24mm thick double glazed, factory finished, comprising interior aluminum transom frames, aluminum mullions, double glazed, insulation, end mullions, aluminum sheet flashing and copping, caps, additional decorative frames, automatic/manual doors within curtain wall Note: with all accessories, U.V. resistant structural sealing compound, window, pre-filler, structural silicone, backing rod, gasketing, fire rating, hardware sets, all fitting and fixing accessories, complete as shown on detailed drawings and as per specifications (Cont`d) Code Description Remarks Unit of Measurement Quantity A Ref. CW 11, size 1900x3350mm No 1 B REF; CW 12, size 4610mm x 3350mm No 4 C REF; CW 13, size 5560 x3350mm, including double leaf sliding door size 2150 x 2195mm No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - FINISHES - Page No. 9.1 BILL NO. 03 - FINISHES - Page No. 9.1 Code Description Note: DIVISION 09 - FINISHES Note: Internal Finishes Note: Backgrounds Note: Floor Screed Note: Supply and install Cement and sand screed with self levelling compound; including sand filling, surface preparation, and all necessary works; complete all in according to drawings and specifications Code Description Remarks Unit of Measurement Quantity A To receive porcelain tiles m2 1,121 B To receive carpet flooring m2 138 C To receive epoxy paint m2 69 Code Description Note: Plaster Note: Supply and install 20mm thick cement and sand plaster to block or concrete walls and columns including metal lath and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity D To receive wall paint m2 2,824 E To receive wall tile m2 487 Code Description Note: Supply and install cement sand plaster to soffits including all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity F To receive paint finish m2 67 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - FINISHES - Page No. 9.2 BILL NO. 03 - FINISHES - Page No. 9.2 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: Internal Finishes (Cont'd) Note: Internal Finishes Note: Floor Finishes Note: Supply and apply Heavy duty free solvent epoxy coating including all necessary works complete in accordance with specifications and drawings (Screed measured separately) Code Description Remarks Unit of Measurement Quantity A Ref-FF04 m2 69 Code Description Note: Supply and install porcelain tiles flooring including bedding materials, matching colored grout, polished, jointing floor transition strips and acoustic underlay (where required) and all necessary works complete in accordance with specifications and drawings (Screed measured separately) Code Description Remarks Unit of Measurement Quantity B Ref-FF01, porcelain tiles, Size 600x600mm m2 1,107 Code Description Note: Supply and install Unglazed non skid Porcelain tiles flooring including bedding materials, matching colored grout, polished, jointing floor transition strips and acoustic underlay (where required) and all necessary works complete in accordance with specifications and drawings (Screed measured separately) Code Description Remarks Unit of Measurement Quantity C Ref-FF02, porcelain tiles, Size 300x300mm m2 104 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - FINISHES - Page No. 9.3 BILL NO. 03 - FINISHES - Page No. 9.3 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: Internal Finishes (Cont'd) Note: Floor Finishes (Cont'd) Note: Supply and install carpet roll on terrazzo tiles, including cushion, trim accessories, acoustical underlayment's, and all necessary works complete in accordance with specifications and drawings (Screed measured separately) Code Description Remarks Unit of Measurement Quantity A Ref-FF03, carpet roll on terrazzo tiles, 250x250x25mm m2 138 Code Description Note: Supply and install terrazzo tiles including grouting, jointing, control joint, bedding material and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity B Terrazzo tiles m2 138 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - FINISHES - Page No. 9.4 BILL NO. 03 - FINISHES - Page No. 9.4 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: Internal Finishes (Cont'd) Note: Threshold Note: Supply and install marble threshold including bedding materials, waterproofing, grouting, jointing and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A 200mm wide, 30mm thick m 4 B 300mm wide, 30mm thick m 44 Code Description Note: Skirting Note: Supply and install porcelain tile skirting including backing, jointing and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C Ref-Sk01, high heavy duty porcelain tiles skirting, 100mm m 796 Code Description Note: Walls Finishes Note: Supply and install porcelain wall tiling fixed with approved adhesive including backing, jointing, corner trim and all necessary works complete in accordance with specifications and drawings (Plaster measured separately) Code Description Remarks Unit of Measurement Quantity D Ref-WF-02, porcelain tiles, Size 300 x 600mm m2 467 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - FINISHES - Page No. 9.5 BILL NO. 03 - FINISHES - Page No. 9.5 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: Internal Finishes (Cont'd) Note: Ceiling Finishes Note: Supply and install 12mm thick gypsum board ceiling including access panel, suspension system, light cove, supports, channels, shadow gap, clips, angles, fixing, fittings and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Ref-CL-01 m2 1,210 Code Description Note: Supply and install powder coated & anti bacteria aluminium tile ceiling including access panel, suspension system, supports, channels, clips, angles, fixing, fittings and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Ref-CL-02, Size 600 x 600mm m2 102 Code Description Note: Supply and install 12.5mm thick suspended gypsum board bulkhead including paint finish, suspension system, supports, fixing, fittings and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C Gypsum bulkhead, Ref. CL-01 , 350mm high m 3 C Gypsum bulkhead, Ref. CL-01 , 400mm high m 100 D Gypsum bulkhead, Ref. CL-01 , 550mm high m 35 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - FINISHES - Page No. 9.6 BILL NO. 03 - FINISHES - Page No. 9.6 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: Internal Finishes (Cont'd) Note: Painting and Decoration Note: Supply and install emulation high quality 100 % pure anti fungal & anti microbial (bacteria) highly washable paint , Matt finish, including backing, jointing, corner trim and all necessary works complete in accordance with specifications and drawings (Plaster measured separately) Code Description Remarks Unit of Measurement Quantity A Ref-WF-01, Emulation paint m2 2,789 Code Description Note: Supply and install emulation paint including all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Ref-CL-03 m2 67 Code Description Note: Supply and apply paint finish including surface preparation, primer coat, final coat and all necessary works complete in accordance with specifications and drawings (Plaster measured separately) Code Description Remarks Unit of Measurement Quantity C To gypsum board ceiling, paint Ref-CL-01 m2 1,210 D To powder coated aluminum and anti bacteria ceiling tiles , Ref-CL-02 m2 102 E T o bulk heads m2 60 Code Description Note: Supply and install anti-fungal paint including all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity F To walls, above false ceiling wet areas m2 179 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - FINISHES - Page No. 9.7 BILL NO. 03 - FINISHES - Page No. 9.7 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: External Finishes Note: Backgrounds Note: Floor Screed Note: Supply and install Cement and sand screed with self levelling compound; including sand filling, surface preparation, and all necessary works; complete all in according to drawings and specifications Code Description Remarks Unit of Measurement Quantity A To receive granite tiles m2 103 Code Description Note: Plaster Note: Supply and install cement and sand plaster to block or concrete walls and columns including metal lath and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B To external block or concrete walls and columns, to receive paint finish m2 1,641 C To external block or concrete walls and columns, to receive Ribbed stone Tiles m2 240 Code Description Note: Floor Finishes Note: Supply and install granite tiles flooring including bedding materials, matching colored grout, polished, jointing floor transition strips and acoustic underlay (where required) and all necessary works complete in accordance with specifications and drawings (screed measured separately) Code Description Remarks Unit of Measurement Quantity D Ref-FF05, Granite tiles m2 103 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - FINISHES - Page No. 9.8 BILL NO. 03 - FINISHES - Page No. 9.8 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: External Finishes (Cont`d)) Note: Skirting Note: Supply and install granite skirting including backing, adhesive and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Ref-SK-02, 100x600x20mm granite m 5 Code Description Note: Painting and Decoration Note: Supply and apply paint finish including surface preparation, primer coat, final coat and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B To plastered walls, Ref. EF 01 m2 1,641 Code Description Note: Stone Cladding Note: Supply and install Ribbed stone tiles including backing, fixing, fittings and all necessary work, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C To external elevation, ref.EF 02, Ribbed stone tiles m2 240 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - ACCESSORIES - Page No. 10.1 BILL NO. 03 - ACCESSORIES - Page No. 10.1 Code Description Note: DIVISION 10 - ACCESSORIES Note: Sanitary Fixture & Accessories Note: Supply and install sanitary fixtures and accessories including fittings, fixings, connections and all necessary works complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity A Ref. BD-001, Hand Spray Bidet No 9 B Ref. FB-001, Wall-mounted dual flush actuator plate for concealed cistern No 14 C Ref. FC-001, Single-lever basin mixer tap No 14 D Ref. FD01, 800mm Stainless steel linear shower drain(Axor finish set) No 6 E Ref. FD03, Floor drain No 20 F Ref. LAV-001, Wash basin No 14 G Ref. LAV-003, Wash basin 450x450 No 1 H Ref. SH-001, Wall-mounted shower set with mixer handheld shower, and adjustable rail No 6 J Ref. STB-001, Toilet paper holder, stain steel recessed No 14 K Ref. STB-003, Security clothing hook No 2 L Ref. STB-005, Mediclinic steel paper No 17 M Ref. TB-004, Medicare grab rail for wall mountain No 21 N Ref. TB-005, Vertical grab rail for Toilet Handicap No 27 P Ref. TB-006, Grab bar manufactured by mediclinics in steel bar No 6 Q Ref. TB-007, Free-standing pedal bin with removable insert and softclose No 14 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - ACCESSORIES - Page No. 10.2 BILL NO. 03 - ACCESSORIES - Page No. 10.2 Code Description Note: DIVISION 10 - ACCESSORIES(CONT'D) Note: Sanitary Fixture & Accessories(Cont'd) Note: Supply and install sanitary fixtures and accessories including fittings, fixings, connections and all necessary works complete in accordance with the specifications and drawings(cont'd) Code Description Remarks Unit of Measurement Quantity A Ref. TB-008, Foam soap No 18 B Ref. TB-009, Sanitary tap mixer No 7 C Ref. WC-002, wall hung vitreous china water closet with concealed tank connection No 14 D Sink No 3 E Circular Wash Basin No 1 F Vanity with counter No 1 Code Description Note: Mirrors Note: Supply and install mirror fixed on and including backing, frame, beveled edge and groove; all in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity G Ref. TB-002, Size 600x900x8mm thick Item 1 Code Description Note: Vanity Counters Note: Supply and install vanity counters including fascia panel, splash back, supports, cut-out for wash basin, fittings, fixing, accessories, sealant and all necessary works complete in accordance with the specifications and drawings (wash basin measured elsewhere) Code Description Remarks Unit of Measurement Quantity H Size 1500 x 600 mm with 1 No, cut basin, 380mm drop fascia No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - ACCESSORIES - Page No. 10.3 BILL NO. 03 - ACCESSORIES - Page No. 10.3 Code Description Note: DIVISION 10 - ACCESSORIES(CONT'D) Note: Glass partitions Note: Supply and install glass partitions including doors, hardware, fixings, forming, openings, all fittings and accessories complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Ref. PAR-01, size 4305 x 3000 mm, including 1 No. door size 1100 x 2000 mm No 1 B Ref. PAR-02, size 4360 x 3000 mm, including 1 No. door size 1100 x 2000 mm No 1 C Ref. PAR-03, size 4255 x 3000 mm, including 1 No. door size 1100 x 2200 mm No 1 D Ref. PAR-04, size 3655 x 2200 mm, including 1 No. door size 1100 x 2200 mm No 1 E Ref. PAR-06, size 2710 x 2200 mm, including 1 No. door size 1210 x 2200 mm No 2 F Ref. PAR-07, size 2360 x 2200 mm, including 1 No. door size 1190 x 2200 mm No 1 G Ref. PAR-08, size 4350 x 3000 mm, including 1 No. door size 1185 x 2220 mm No 1 Code Description Note: Ablution Seats Note: Supply and install ablution seat including marble top, 20mm thick, ceramic tiles on mortar beds, reinforcement concrete, waterproofing, fixing, accessories, sealant and all necessary works complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity H Ablution Seat Item 1 Code Description Note: Signage Code Description Remarks Unit of Measurement Quantity J Supply and install signage including all fittings, fixings, support, accessories and all in accordance with specifications and drawings Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - FURNISHINGS - Page No. 12.1 BILL NO. 03 - FURNISHINGS - Page No. 12.1 Code Description Note: DIVISION 12 - FURNISHINGS Note: Loose Furnitures Note: Supply and install furniture including fittings, fixing, hardware, accessories and all related works, complete in accordance with drawings and specifications Code Description Remarks Unit of Measurement Quantity A Ref. BD-01, Single Wooden Bedroom (1.00x2.20)m No 12 B Ref. BD-02, Clinic Bedroom (1.00x2.00)m No 1 C Ref. BT-01, Wooden Comod 400x400mm No 12 D Ref. CF-LCA-01, Base cabinet with laminate doors, solid-surface countertop, and drop-in sink No 3 E Ref. CF-UCA-01, Wall-mounted upper kitchen cabinet with hinged laminate doors No 3 F Ref. CH-01, Chair high back wooden leg No 13 G Ref. CH-02, Wooden office chair (0.65x0.65)m No 6 H Ref. CH-03, 5 Star base fully upholstered with arms No 36 J Ref. CH-04, Wooden Chair with high long back leg No 17 K Ref. CH-05, Wooden table for four chair No 16 L Ref. CH-06, Ergonomic swivel office chair with armrests and headset No 12 M Ref. CP-01, Carpet (4x3)m No 3 N Ref. DSK-01, Wooden office desk (1.75x0.75)m No 14 P Ref. DSK-02, Wooden office desk (2.5x0.75)m No 3 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - FURNISHINGS - Page No. 12.2 BILL NO. 03 - FURNISHINGS - Page No. 12.2 Code Description Note: DIVISION 12 - FURNISHINGS (Cont'd) Note: Loose Furnitures (Cont'd) Note: Supply and install furniture including fittings, fixing, hardware, accessories and all related works, complete in accordance with drawings and specifications. (Cont'd) Code Description Remarks Unit of Measurement Quantity A Ref. DT-01, Wooden table for six chair No 3 B Ref. DT-02, Wooden table for four chair No 1 C Ref. KC-01, Base cabinet unit with laminate doors, solid-surface countertop- and drop-in sink No 1 D Ref. MR-01, Bathroom Mirror No 2 E Ref. SF-01, Sofa for Reception area (2.40x1.00)m No 3 F Ref. SF-02, Sofa arm chair for Reception area (2.40x1.00)m No 3 G Ref. SF-03, Reception wooden table (1.00x0.55)m No 1 H Ref. TB-01, Wooden stand stable with glass No 11 J Ref. TB-02, Wooden bedroom table (1.50x.50)m No 6 K Ref. TB-03, Wooden stand stable with glass No 3 L Ref. TB-04, meeting room table for 6 person No 2 M Ref. TB-04, meeting room table for 6 person No 5 N Ref. TB-06, Wooden office for staff room No 12 P Ref. TB-07, Wooden office for staff room No 3 Q Ref. TV-01, TV Reception area No 3 R Ref. TV-TB-01, Reception counter (1.40x0.501)m No 3 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - FURNISHINGS - Page No. 12.3 BILL NO. 03 - FURNISHINGS - Page No. 12.3 Code Description Note: DIVISION 12 - FURNISHINGS (Cont'd) Note: Loose Furnitures (Cont'd) Note: Supply and install furniture including fittings, fixing, hardware, accessories and all related works, complete in accordance with drawings and specifications. (Cont'd) Code Description Remarks Unit of Measurement Quantity A Ref. WR-01, Deskdrawer for bedroom (2.30x0.55)m No 6 B Ref. WR-02, Deskdrawer for gem (4.00x0.55)m No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION - Page No. 15.1 BILL NO. 03 -MECH INSTALLATION - Page No. 15.1 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS Note: Rainwater, soil, waste, and vent pipework installations complete in accordance with specifications and drawings Note: Pipework Note: Above ground uPVC pipework including fittings, accessories, insect screen, and all necessary works complete in accordance with drawings and specifications Code Description Remarks Unit of Measurement Quantity A 50mm diameter m 16 B 82mm diameter m 34 C 110mm diameter m 88 Code Description Note: Under ground uPVC pipework including excavation, backfilling, warning tap, fittings, accessories, and all necessary works complete in accordance with drawings and specifications Code Description Remarks Unit of Measurement Quantity D 50mm diameter m 90 E 82mm diameter m 25 F 110mm diameter m 197 Code Description Note: Fittings, complete in accordance with drawings and specifications Note: Rain Water Drain Code Description Remarks Unit of Measurement Quantity G Ref. RWO, 110mm diameter No 16 Code Description Note: Floor Drain Code Description Remarks Unit of Measurement Quantity H Ref. FD, 150x150mm No 21 Code Description Note: Floor Cleanout Code Description Remarks Unit of Measurement Quantity J Ref. FCO 110mm diameter No 28 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.2 BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.2 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Vent Cowl Code Description Remarks Unit of Measurement Quantity A Size 82mm No 7 B Size 110mm No 3 Code Description Note: Grating Cover Code Description Remarks Unit of Measurement Quantity C Grating cover, size 1800x200mm No 3 D Grating cover, size 2000x500mm No 2 E Shower Grating, size 800x70mm No 6 Code Description Note: Domestic Hot and Cold Water Installation Note: Cold Water Supply System Note: Supply and install cold water PPR pipe works including necessary, fittings, valves and accessories, and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity F 20mm diameter m 331 G 25mm diameter m 21 H 32mm diameter m 37 J 32mm diameter, circulation pipe m 8 K 40mm diameter m 8 L 40mm diameter, water transfer line m 31 M 50mm diameter m 44 N 65mm diameter m 1 P 100mm diameter m 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.3 BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.3 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Domestic Hot and Cold Water Installation Note: Hot Water Supply System Note: Supply and install hot water PPR pipe works with insulation including necessary, fittings, valves and accessories, and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A 20mm diameter m 242 B 25mm diameter m 113 C 32mm diameter m 49 Code Description Note: Pumps Note: Supply, install test and commission domestic water pumps set with control panels, valves, check valves, fittings, supports, flexible connections, electrical works, vibration isolation, electronic pressure controller, pressure gauges, protections and all required components and accessories as per drawings and specifications Code Description Remarks Unit of Measurement Quantity D Domestic water booster pump set, flow 1.60 L/S, head 2.50 Bar, (1 Duty, 1 Standby). No 2 E Domestic water circulation pump set, flow 1.60 L/S, head 2.50 Bar, (1 Duty, 1 Standby). No 2 Code Description Note: Hot Water Pump Code Description Remarks Unit of Measurement Quantity F Hot water return pump set, flow 1.60 L/S, head 2.50 Bar, (1 Duty, 1 Standby). No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.4 BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.4 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Domestic Hot and Cold Water Installation (Cont'd) Note: Demotic Water Tank Note: GRP hot pressed panel type, sectional insulated water tank including connections, float valve, pipes, access panel, fitting, accessories and valves and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A Size 4.0 x 2.50 x 1.50 m, capacity 15.0 m3 No 1 Code Description Note: Solar System Note: Supply, install, test and commission flat plate solar system. Including collectors, tanks, short pipes, vent, valves, complete with all fittings, supports and all required accessories as per drawings & specifications. Code Description Remarks Unit of Measurement Quantity B Flat plate solar system, (3 Collectors) No 1 Code Description Note: Pressure Vessel Code Description Remarks Unit of Measurement Quantity C Pressure vessel, capacity 100 L No 1 Code Description Note: UV Sterilization Unit Note: Supply, install test and commission UV Sterilization complete with all required components and accessories as per drawings and specifications Code Description Remarks Unit of Measurement Quantity D UV sterilization unit, 1.6 L/s No 1 Code Description Note: Domestic Cooler Unit Note: Supply, install test and commission domestic cooler unit complete with valves, fittings, supports, electrical works, and all required components and accessories as per drawings and specifications Code Description Remarks Unit of Measurement Quantity E Cooler unit, cooling capacity 10.5 kw No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.5 BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.5 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Domestic Hot and Cold Water Installation (Cont'd) Note: Estidama Water Meter Note: Supply and install estidama water meter including valves, fitting with all required accessories as per drawings and specifications Code Description Remarks Unit of Measurement Quantity A Estidama water meter, ref EWM-01 No 1 B Estidama water meter, ref EWM-02 No 1 Code Description Note: Isolating Valves Code Description Remarks Unit of Measurement Quantity C 15mm diameter No 4 D 20mm diameter No 52 E 32mm diameter No 5 F 40mm diameter No 1 G 50mm diameter No 3 H 50mm diameter (NC) No 1 Code Description Note: Bib Tap Code Description Remarks Unit of Measurement Quantity J 15mm diameter No 4 K 20mm diameter No 1 Code Description Note: Ball Valves Code Description Remarks Unit of Measurement Quantity L 20mm diameter No 15 Code Description Note: Gate Valves Code Description Remarks Unit of Measurement Quantity M 25mm diameter No 3 N 32mm diameter No 3 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.6 BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.6 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Domestic Hot and Cold Water Installation (Cont'd) Note: Water Hammer Arrestor Code Description Remarks Unit of Measurement Quantity A 20mm diameter No 36 Code Description Note: Fire Fighting System Note: Supply and install black steel fire fighting water pipe works including drain pipes, fittings, accessories valve and supports and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B 25mm diameter m 454 C 25mm diameter, drain pipe m 2 D 32mm diameter m 30 E 40mm diameter m 46 F 50mm diameter m 31 G 65mm diameter m 35 H 65mm diameter, wet riser pipe m 24 J 80mm diameter m 30 K 80mm diameter, wet riser pipe m 9 L 100mm diameter m 31 M 150mm diameter m 20 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.7 BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.7 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Fire Fighting System (Cont'd) Note: Fire Hose Cabinet Note: Supply, install, test and commission hose station consist of a 25 mm hose reel & a 65 mm diameter landing valve including but not limited to cabinets, reels, fire extinguishers, isolating valves, pressure regulating valves, pressure reducing valves hoses, nozzles, marking, fixings, supports and all required components and accessories as per drawings, specifications and civil defense regulations. Code Description Remarks Unit of Measurement Quantity A Ref FHC No 2 Code Description Note: Frie Extinguisher Note: Supply install test and commission fire extinguisher including but not limited to wall fixing frame and hanger and all required components and accessories as per drawings, specifications and civil defense regulations. Code Description Remarks Unit of Measurement Quantity B 5 Kg dry CO2 fire extinguisher No 4 C 4.5 Kg dry powder fire extinguisher No 2 D FFP foam trolly type 33 gal. No 1 Code Description Note: Fire Blanket Note: Supply and fix fire blanket including all accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity E Fire Blanket, ref FB No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.8 BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.8 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Fire Fighting System (Cont'd) Note: Automatic Air Vent Note: Supply and install automatic air vent including all accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Automatic air vent, ref AAV, 150mm No 1 Code Description Note: Sprinkler Heads Note: Supply and install Sprinkler Heads including all fittings and accessories complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Pendant sprinkler head No 156 Code Description Note: Valves and other fittings complete in accordance with specification and drawings Note: Zone Control Valve Code Description Remarks Unit of Measurement Quantity C ZCV, 150mm No 1 Code Description Note: Pressure Reducing Valve Code Description Remarks Unit of Measurement Quantity D PRV, 150mm No 1 Code Description Note: Non-Return Valve Code Description Remarks Unit of Measurement Quantity E NRV, 150mm No 1 Code Description Note: Breeching Inlet Code Description Remarks Unit of Measurement Quantity F 150mm diaX 4 Way breeching inlet for sprinkler and wet riser systems No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.9 BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.9 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation Note: Ductwork Note: Design, fabrication and installation of galvanized sheet metal ductwork including circular duct work, supports, fittings and accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A Supply duct Kg 4,255 B Return duct Kg 579 C Fresh duct Kg 900 D Exhaust duct Kg 683 E Toilet extract duct Kg 771 F Flexible supply air duct 200mm diameter m 17 Code Description Note: Internal Duct Insulation Note: Supply and install internal insulation for duct and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity G For supply duct m2 743 H For return duct m2 62 J Toilet extract duct m2 75 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.10 BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.10 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation (Cont'd) Note: External Duct Insulation Note: Supply and install insulation for external duct with aluminum cladding and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A Supply duct m2 37 B Return duct m2 36 C For fresh duct m2 147 D For exhaust duct m2 123 E Toilet extract duct m2 89 Code Description Note: Fresh Air Handling Units Note: Supply and install fresh air handling units including connections to the ducts, controls, anti vibration mountings, thermostat, smoke detectors, sensors, filters, coil, protective devices and drain and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity F FAHU-01 air flow rate 2700 L/s, cooling capacity 22.52 kw No 1 Code Description Note: Condensate Unit Note: Supply and install condensate unit including connections to the pipes, controls, anti vibration mountings, thermostat, smoke detectors, sensors, filters, coil, protective devices and drain and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity G CU/01-FAHU-01 No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.11 BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.11 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation(Cont'd) Note: Package Units Note: Supply, install, test and commission package unit, including but not limited to insulation, electrical and control wiring, cables, thermostats, control devices, supports, fittings, vibration isolation and all required components and accessories as per drawings, specifications and according to manufacturers requirements. Code Description Remarks Unit of Measurement Quantity A Ref. GF-PU-01, flow rate 3505 L/s No 1 B Ref. GF-PU-02, flow rate 1830 L/s No 1 C Ref. GF-PU-03, flow rate 2275 L/s No 1 D Ref. GF-PU-04, flow rate 1516 L/s No 1 E Ref. GF-PU-05, flow rate 2275 L/s No 1 Code Description Note: Fans Note: Supply and install fans including connections, fittings, back draft, and accessories and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity F Ref. 02-EXF-01, flow rate 57 L/s No 3 Code Description Note: Sound Attenuator Code Description Remarks Unit of Measurement Quantity G Sound attenuator ref. SA, size 600x550mm No 1 H Ditto ref. SA, size 650x600mm No 1 J Ditto ref. SA, size 650x650mm No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.12 BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.12 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation(Cont'd) Note: Sound Attenuator (Cont'd) Code Description Remarks Unit of Measurement Quantity A Ditto ref. SA, size 800x500mm No 1 B Ditto ref. SA, size 850x750mm No 1 C Ditto ref. SA, size 900x500mm No 1 Code Description Note: Variable & Constant Air Volume System Note: Supply and install VAV/CAV box including connections, fittings, and accessories and all necessary works complete in accordance with specification and drawings Note: Variable Air Volume Code Description Remarks Unit of Measurement Quantity D Ref. 01-VAV-01, flow rate 337 L/s No 1 E Ref. 01-VAV-02, flow rate 242 L/s No 1 F Ref. 01-VAV-03, flow rate 245 L/s No 1 G Ref. 01-VAV-04, flow rate 228 L/s No 1 H Ref. 01-VAV-05, flow rate 295 L/s No 1 J Ref. 01-VAV-06, flow rate 233 L/s No 1 K Ref. 01-VAV-07, flow rate 127 L/s No 1 L Ref. 01-VAV-08, flow rate 63 L/s No 1 M Ref. 01-VAV-09, flow rate 63 L/s No 1 N Ref. 01-VAV-10, flow rate 144 L/s No 1 P Ref. 01-VAV-11, flow rate 125 L/s No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.13 BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.13 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation(Cont'd) Note: Variable & Constant Air Volume System (Cont'd) Note: Variable Air Volume (Cont'd) Code Description Remarks Unit of Measurement Quantity A Ref. 01-VAV-12, flow rate 837 L/s No 1 B Ref. 01-VAV-13, flow rate 319 L/s No 1 C Ref. 01-VAV-14, flow rate 195 L/s No 1 D Ref. 01-VAV-15, flow rate 195 L/s No 1 E Ref. 01-VAV-16, flow rate 195 L/s No 1 F Ref. 01-VAV-17, flow rate 414 L/s No 1 G Ref. 01-VAV-18, flow rate 249 L/s No 1 H Ref. 01-VAV-19, flow rate 60 L/s No 1 J Ref. 01-VAV-20, flow rate 158 L/s No 1 K Ref. 01-VAV-21, flow rate 517 L/s No 1 L Ref. 01-VAV-22, flow rate 202 L/s No 1 M Ref. 01-VAV-23, flow rate 225 L/s No 1 N Ref. 01-VAV-24, flow rate 125 L/s No 1 P Ref. 01-VAV-25, flow rate 219 L/s No 1 Q Ref. 01-VAV-26, flow rate 353 L/s No 2 R Ref. 01-VAV-27, flow rate 399 L/s No 1 S Ref. 01-VAV-28, flow rate 18 L/s No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.14 BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.14 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation(Cont'd) Note: Variable & Constant Air Volume System (Cont'd) Note: Variable Air Volume (Cont'd) Code Description Remarks Unit of Measurement Quantity A Ref. 01-VAV-29, flow rate 65 L/s No 1 B Ref. 01-VAV-30, flow rate 91 L/s No 1 C Ref. 01-VAV-31, flow rate 397 L/s No 1 D Ref. 01-VAV-32, flow rate 267 L/s No 1 E Ref. 01-VAV-33, flow rate 267 L/s No 1 F Ref. 01-VAV-34, flow rate 267 L/s No 1 G Ref. 01-VAV-35, flow rate 287 L/s No 1 H Ref. 01-VAV-36, flow rate 477 L/s No 1 J Ref. 01-VAV-37, flow rate 95 L/s No 1 K Ref. 01-VAV-38, flow rate 65 L/s No 1 Code Description Note: Constant Air Volume Code Description Remarks Unit of Measurement Quantity M Ref. 01-CAV-01, flow rate 132 L/s No 1 N Ref. 01-CAV-02, flow rate 250 L/s No 1 P Ref. 01-CAV-03, flow rate 188 L/s No 1 Q Ref. 01-CAV-04, flow rate 140 L/s No 1 R Ref. 01-CAV-05, flow rate 122 L/s No 1 S Ref. 01-CAV-06, flow rate 542 L/s No 2 T Ref. 01-CAV-07, flow rate 50 L/s No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.15 BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.15 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation(Cont'd) Note: DX Unit Note: Supply, install, test and commission DX unit cooling only including but not limited to indoor & outdoor units, vibration isolation, control wiring, flexible connectors, integral control, hanger, supports, filters, sleeves, condensate piping and all required accessories as per drawings and specifications. Code Description Remarks Unit of Measurement Quantity A 02-SP-01 / CU/02-SP-01, air side 133 L/s No 1 Code Description Note: Dampers Note: Supply and install damper including connections, fittings and accessories and all necessary works complete in accordance with specification and drawings Note: Volume Control Damper Code Description Remarks Unit of Measurement Quantity B Volume control damper ref. VCD size 100X100mm No 1 C Ditto ref. VCD size 150X100mm No 10 D Ditto ref. VCD size 200x150mm No 10 E Ditto ref. VCD size 250x150mm No 1 F Ditto ref. VCD size 300x150mm No 2 G Ditto ref. VCD size 300x200mm No 1 H Ditto ref. VCD size 300x250mm No 3 J Ditto ref. VCD size 350x150mm No 1 K Ditto ref. VCD size 350x250mm No 3 L Ditto ref. VCD size 350x300mm No 1 M Ditto ref. VCD size 350x350mm No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.16 BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.16 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Volume Control Damper (Cont'd) Code Description Remarks Unit of Measurement Quantity A Volume control damper ref. VCD size 400x150mm No 1 B Ditto ref. VCD size 400x250mm No 4 C Ditto ref. VCD size 400x300mm No 1 D Ditto ref. VCD size 450x150mm No 1 E Ditto ref. VCD size 450x200mm No 4 F Ditto ref. VCD size 500x150mm No 2 G Ditto ref. VCD size 500x250mm No 1 H Ditto ref. VCD size 500x550mm No 1 J Ditto ref. VCD size 600x250mm No 2 K Ditto ref. VCD size 600x400mm No 1 L Ditto ref. VCD size 600x450mm No 1 M Ditto ref. VCD size 650x150mm No 1 N Ditto ref. VCD size 650x200mm No 2 P Ditto ref. VCD size 650x300mm No 3 Q Ditto ref. VCD size 650x650mm No 6 R Ditto ref. VCD size 750x300mm No 1 S Ditto ref. VCD size 850x700mm No 1 T Ditto ref. VCD size 200mm diameter No 36 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.17 BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.17 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Volume Control Damper (Cont'd) Note: Dampers (Cont'd) Note: Fire Damper Code Description Remarks Unit of Measurement Quantity A Fire damper ref. FD, size 150x100mm No 9 B Ditto ref. FD, size 400x250mm No 2 C Ditto ref. FD, size 500x5500mm No 1 D Ditto ref. FD, size 650x300mm No 2 E Ditto ref. FD, size 650x650mm No 3 F Ditto ref. FD, size 850x700mm No 1 Code Description Note: Motorized Damper Code Description Remarks Unit of Measurement Quantity G Motorized damper ref. MD, size35x350mm No 1 H Ditto ref. MD, size 400x300mm No 1 J Ditto ref. MD, size 400x350mm No 1 K Ditto ref. MD, size 400x350mm (NC) No 1 L Ditto ref. MD, size 550x400mm No 3 M Ditto ref. MD, size 600x250mm No 1 N Ditto ref. MD, size 650x300mm No 1 P Ditto ref. MD, size 650x400mm No 1 Q Ditto ref. MD, size 700x400 No 1 Code Description Note: Non-Return Damper Code Description Remarks Unit of Measurement Quantity R Ditto ref. NRD, size 150x100mm No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.18 BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.18 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation(Cont'd) Note: Diffusers, Grills, Dampers, Liner diffusers Note: Supply and return air slot diffuser with integrated opposed blades volume damper and with adjustable deflection blades with 25mm thick acoustic one plenum box. Code Description Remarks Unit of Measurement Quantity A Ref. SLD, 1000mm length, 1-slot No 38 B Ref. RLD, 1000mm length, 1-slot No 38 Code Description Note: Supply and return air diffuser Code Description Remarks Unit of Measurement Quantity C Ref. SD 150x100mm No 2 D Ref. SD 150x150mm No 6 E Ref. SD 225x225mm No 17 F Ref. SD 300x300mm No 23 G Ref. SD 375x375mm No 20 H Ref. RD 150x100mm No 2 J Ref. RD 150x150mm No 6 K Ref. RD 225x225mm No 17 L Ref. RD 300x300mm No 23 M Ref. RD 375x375mm No 19 Code Description Note: Disk Valve Code Description Remarks Unit of Measurement Quantity N Ref. DV 150mm diameter No 18 Code Description Note: Exhaust Diffuser Code Description Remarks Unit of Measurement Quantity P Ref. EAD 150x150mm No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.19 BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.19 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation(Cont'd) Note: Diffusers, Grills, Dampers, Liner diffusers(Cont'd) Note: Round supply and return air diffuser with adjustable butter fly control dampers(CONT'D) Note: Supply Grille Code Description Remarks Unit of Measurement Quantity A Ref. SG 100x100mm No 1 B Ref. SG 300x300mm No 1 C Ref. SG 350x150mm No 1 D Ref. SG 500x200mm No 2 Code Description Note: Return Grille Code Description Remarks Unit of Measurement Quantity E Ref. RG 100x100mm No 1 F Ref. RG 300x300mm No 1 G Ref. RG 350x150mm No 1 H Ref. RG 500x200mm No 2 Code Description Note: Exhaust Air Louver Code Description Remarks Unit of Measurement Quantity J EAL, with bird screen, 2700 L/s, face area 1.35m2 No 1 K EAL, with bird screen, 570 L/s, face area 0.50m2 No 1 Code Description Note: Fresh Air Louver Code Description Remarks Unit of Measurement Quantity L FAL, with sand trap and insect screen, 2195 L/s, face area 1.95m2 No 1 Code Description Note: Building Management System (BMS) Code Description Remarks Unit of Measurement Quantity M Supply, install, test and commissioning of Building management system including points, wires, conduits, and all necessary works complete in accordance with specifications and drawings Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.20 BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.20 Code Description Note: Sundry / General Items Code Description Remarks Unit of Measurement Quantity A Allow for permits, connection and inspection fees associated with mechanical installations by utility and statutory authorities Item 1 B Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings Item 1 C Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment Item 1 D Allow for setting out the works, marking positions of holes, mortises, chases or the like Item 1 E Allow for testing and commissioning and submission of test certificates Item 1 F Allow for all identification labels, plates, charts and identification of plant, equipment, cable, isolators and the like Item 1 G Allow for preparing schedule of manufacturers recommended tools and spare parts for each piece of equipment Item 1 H Allow for the provision of operating/maintenance manuals Item 1 J Allow for providing shop and coordination drawings Item 1 K Allow for domestic water piping, sterilization and disinfections after commissioning Item 1 L Allow for flushing chilled water system pipe work with water and establishment of rust inhibitor before commissioning Item 1 M Allow for fire stopping in accordance with the drawings, specification and local authorities requirements Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1 BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS Note: Power System installations Note: Automatic Transfer Switch (ATS) Note: Supply and install automatic transfer switch including fixing, fittings, terminations, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A ATS 63A No 1 Code Description Note: Generator Note: Supply, install, test, commission and maintain, prime rated generator including, but not limited to, lubrication system, control panels, fuel system and all associated devices and equipment, earthing, and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Standby diesel generator 18KW/22KVA No 1 Code Description Note: Main &Sub Main Distribution Boards Note: Supply, install, test, commission, and maintain main and sub-main distribution boards and terminations, including bus bars, breakers, indicators, meters, all interconnecting cables, wires termination, energy monitoring meters, and trays from the main board, and all necessary works complete in accordance with specification and drawings Note: Main Distribution Boards Code Description Remarks Unit of Measurement Quantity C Main distribution boards, ref MDB-PD No 1 D Ditto, ref MDB-PD-AC No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2 BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Power System Installations (Cont'd) Note: Main &Sub Main Distribution Boards (Cont'd) Note: Supply, install, test, commission, and maintain main and sub-main distribution boards and terminations, including bus bars, breakers, indicators, meters, all interconnecting cables, wires termination, energy monitoring meters, and trays from the main board, and all necessary works complete in accordance with specification and drawings Note: Sub Main Distribution Boards Code Description Remarks Unit of Measurement Quantity A Sub main distribution boards, ref ESMDB-PD No 1 Code Description Note: Final Distribution Boards Note: Supply, install, test, commission and maintain Final Distribution boards and terminations including bus bars, breakers, indicators, all interconnecting cables, wires termination and trays from main board, and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Final distribution boards, DB-P4 No 1 C Ditto, ref DB-P5 No 1 D Ditto, ref DB-P6 No 1 E Ditto, ref DB-L2 No 1 F Ditto, ref EDB-L2 No 1 G Lighting control panel, ref LCP No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3 BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Cable Tray Note: Supply and install Cable trunk including fixing, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A 200x100mm cable trunk m 888 B 100x50mm cable trunk with cover m 29 C 400x100mm cable trunk with cover m 55 D 600x100mm cable trunk with cover m 60 Code Description Note: Cables Note: Low Voltage cables including ducts, glands, connections, conduits, termination, trays and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity E 2C.6 mm2 XLPE/SWA/PVC +1C.6 mm2 PVC/ECC/CU m 282 F 2C.6 mm2 fire rated XLPE/SWA/PVC +1C.6 mm2 fire rated PVC/ECC/CU m 95 G 4C.10 mm2 XLPE/SWA/PVC +1C.10 mm2 PVC/ECC/CU m 361 H 4C.10 mm2 fire rated XLPE/SWA/PVC +1C.10 mm2 fire rated PVC/ECC/CU m 58 J 4C.16mm2 XLPE/SWA/PVC +1C.16 mm2 PVC/ECC/CU m 89 K 4C.25mm2 XLPE/SWA/PVC +1C.16 mm2 PVC/ECC/CU m 179 L 4C.25 mm2 fire rated XLPE/SWA/PVC +1C.16 mm2 fire rated PVC/ECC/CU m 17 M 4C.35mm2 XLPE/SWA/PVC +1C.16 mm2 PVC/ECC/CU m 47 N 4C.50mm2 XLPE/SWA/PVC +1C.25 mm2 PVC/ECC/CU m 12 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4 BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Power Distribution Note: Supply and install the following power fittings including all necessary accessories and connections to wiring and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A 13A Single switched socket No 67 B 13A Twin switched socket No 63 C 13A switched socket inside floor box No 64 D 15A Switched socket No 4 E 13A Switched spur outlet No 48 F 13A Unswitched spur outlet No 3 Code Description Note: Power point Note: Supply and install wiring and conduit in concealed installation including cable trays / trucking, access box with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity G Power points No 249 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5 BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Power System Installations (Cont'd) Note: Floor Boxes Note: Supply, and install, floor boxes, including fixing, fitting, with all necessary works complete all in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity A Floor box with two compartments No 32 Code Description Note: Isolating Switch Note: Supply and install isolating switch including all interconnecting and terminations and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity B Isolator single phase 32A No 2 C Isolator single phase 32A IP65 No 5 D Isolator three phase 32A IP65 No 4 E Isolator three phase 40A No 1 F Isolator three phase 40A IP65 No 1 G Isolator three phase 63A IP65 No 4 H Isolator three phase 80A IP65 No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6 BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Power System Installations (Cont'd) Note: Internal Lighting Note: Supply and install lighting including all necessary accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Lighting fixture, type S1 No 26 B Ditto, type S2 No 32 C Ditto, type S3 No 17 D Ditto, type S4 No 134 E Ditto, type S5 No 30 F Ditto, type S6 No 33 G Ditto, type S7 No 12 H Ditto, type W1 No 9 J Ditto, type L1 No 15 Code Description Note: Internal Lighting Points Note: Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity K Internal Lighting points No 308 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.7 BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.7 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Power System Installations (Cont'd) Note: Switches Note: Supply, install, test, commission switches including all necessary accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A One gang, one way lighting switch 20A No 4 B One gang, one way lighting switch 20A, W/P No 3 C Two gang, one way lighting switch 20A No 11 D Three gang, two way lighting switch 20A No 12 E Two gang, one way override switch 20A No 32 F Three gang, one way override switch 20A No 2 G Two gang, two way override switch 20A No 4 H Lux and absence multi sensor No 13 J Presence sensor No 31 K Motion sensor No 21 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.8 BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.8 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Power System Installations (Cont'd) Note: Switches (Cont'd) Note: Supply, install, test, commission switches including all necessary accessories and all necessary works complete in accordance with specifications and drawings Note: Lighting switch Point Note: Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A Lighting switch points No 68 B Sensors points No 65 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.9 BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.9 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Emergency and Exit Lighting System Note: Supply, install, test, commission the following emergency and exit light fittings, including ceiling rose, heat resistance, flexible cable, lamps, electronic control gear, suspensions, connections to permanent wiring system in accordance with Specification and drawings Code Description Remarks Unit of Measurement Quantity A Self-contained 1x8w emergency light with built-in battery (3h duration ), surface-mounted, non-maintained No 5 B Self-contained 1x8w emergency light with built-in battery (3h duration ), recessed mounted, non-maintained No 46 C Self-contained 1x8w exit light maintained with a built-in battery (3h duration ) No 13 D Self-contained 1x8w exit light double-sided, maintained with a built-in battery (3h duration ) No 1 Code Description Note: Emergency lighting points Note: Supply and install wiring and conduit in concealed installation including cable trays / trunking, with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity E Emergency lighting points No 65 Code Description Note: Central Battery System Note: Supply and install central battery system including , pull boxes, junction boxes, wires, and connections to relevant panel complete as shown on drawings and as per specifications Code Description Remarks Unit of Measurement Quantity F Emergency light monitoring panel, ref EMP-POD No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.10 BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.10 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Fire Alarm System Note: Supply, install, test, commission and maintain the complete Analogue addressable fire Alarm & evacuation system including cabling, wiring conduit, cable tray, trunking, termination and power connections and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Intelligent optical smoke detector and standard base No 56 B Smoke detector above ceiling void area No 57 C Intelligent heat detector with standard base No 2 D Intelligent optical smoke detector with sounder base No 6 E Manual call point No 6 F Fire alarm sounder with flasher No 4 G Fire alarm sounder or horn, W/P No 4 H Voice evacuation, ceiling mounted speaker No 24 J Desk type microphone for emergency voice broadcast No 5 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.11 BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.11 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Fire Alarm System (Cont'd) Note: Disabled Alarm System Note: Supply, install, test, commission and maintain the complete Analogue addressable Disabled Alarm System including cabling, wiring conduit, cable tray, trunking, termination and power connections and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Reset point No 2 B Over light door & sounder unit above the door with WC sticker No 2 C Disabled toilet alarm pull cord No 2 D standalone alarm controller & power supply No 2 Code Description Note: Supply, install, test, commission fire alarm control panel with charger and batteries, power supply, fire fighter two way communication, amplifiers, voice evac., alarm system, AUX. output, PC monitor and control, software, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity E Fire alarm and voice evacuation integrated control panel, ref FACP-POD, two loops No 1 F 24/7 DCD monitoring panel No 1 G Voice evacuation control system, VECP-POD No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.12 BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.12 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Telecommunication System Note: Supply, install, test, commission complete telecommunication system, including cabling, wiring, conduits, cables, terminations and power connections and all necessary works complete all in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Single data outlet (RJ45) above ceiling No 1 B Voice outlet (RJ45) wall mounted No 15 C Data outlet for wireless access point outlet ceiling based No 11 D Single data outlet (RJ45) wall mounted for IPTV No 11 E Dual (RJ45) data&voice socket outlet wall mounted No 26 F Data outlet inside floor box No 32 G Telephone outlet inside floor box No 32 Code Description Note: Communications Equipment Note: Supply and install of data and communication equipment and racks; including all kinds of cable, wires, cable trays, and all required components, internal connections, all necessary support, fixings and accessories; and all necessary works complete all in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity H 42U telephone rack No 1 J Proposed server rack at main server room No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.13 BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.13 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: CCTV System Note: Supply install, test and commission complete CCTV system including rack, monitors, controllers , cabling, wiring, conduit and power connections, and all necessary works complete all in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A IP based identification dome camera No 6 B IP based recognition dome camera No 20 C IP based wall mounted weather proof bullet camera detection level No 13 D Future IP dome camera containment includes conduit and CAT6A cable No 20 E Provision for camera No 14 Code Description Note: CCTV Work Station Note: Supply and install CCTV works station, including, computer, screens, printers, and all necessary works complete all in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity F CCTV work stations No 2 Code Description Note: Security Equipment Note: Supply and install of data and security equipment and racks; including all kinds of cable, wires, cable trays, and all required components, internal connections, all necessary support, fixings and accessories; and all necessary works complete all in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity G Security rack 24U, ref MDF-SC-POD No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.14 BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.14 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Access Control System Note: Supply install, test and commission complete access control system including cabling, cable tray, wiring, conduit and power connections, and all necessary works complete all in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Master door control panel No 1 B Door control panel No 7 C Door contact No 27 D Electric mortise lock No 12 E Electro magnetic lock No 15 F Card reader No 18 G Exit push button No 18 H Break glass unit No 18 Code Description Note: Cable Tray Note: Supply and install Cable trays including fixing, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity J 150x50mm HDGI cable tray for GSM m 131 K 200x50mm HDGI cable tray for ICT m 131 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.15 BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.15 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Earthing protection system Note: Supply, install, test and commissioning of earthing protection system including earth pits, conductors, bars ,bonds and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Earthing protection Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.16 BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.16 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Sundry / General Items Code Description Remarks Unit of Measurement Quantity A Allow for permits, connection and inspection fees associated with electrical installations by utility and statutory authorities Item 1 B Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings Item 1 C Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment Item 1 D Allow for setting out the works, marking positions of holes, mortises, chases or the like Item 1 E Allow for testing and commissioning and production of test certificates Item 1 F Allow for all identification labels, plates, charts and identification of plant, equipment, cable, switches and the like Item 1 G Allow for the provision of operating / maintenance manuals Item 1 H Allow for providing shop and coordination drawings Item 1 J Allow for instructing selected employer's personnel on all aspects of the operation of systems and equipment Item 1 K Supply and handover to the client all tools and equipment in accordance with the specification Item 1 L Allow for fire stopping in accordance with the drawings specification and local authorities requirements Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - SITE WORK - Page No. 2.1 BILL NO. 04 - SITE WORK - Page No. 2.1 Code Description Note: DIVISION 02 - SITE WORKS Note: Site Preparation Code Description Remarks Unit of Measurement Quantity A Site Clearance, including removal of rubbish, debris, vegetation, within the designated work area complete accordance with the specifications and drawings m2 25 Code Description Note: Excavation Note: Excavation from existing level to bottom of foundation levels complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Bulk Excavation m3 6 C Pit Excavation m3 16 D Trench Excavation m3 2 Code Description Note: Backfilling Code Description Remarks Unit of Measurement Quantity E Backfilling, including compaction in layer complete in accordance with specifications and drawings m3 10 Code Description Note: Disposal of Material Arising From Excavations Code Description Remarks Unit of Measurement Quantity F Remove surplus excavated material from site to approved location complete in accordance with specifications and drawings m3 14 Code Description Note: Road base Code Description Remarks Unit of Measurement Quantity G Road base, including compaction in layer complete in accordance with specifications and drawings m3 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - SITE WORK (CONT'D) - Page No. 2.2 BILL NO. 04 - SITE WORK (CONT'D) - Page No. 2.2 Code Description Note: DIVISION 02 - SITE WORKS(CONT'D) Note: Anti - Termite Treatment Note: Allow for anti termite treatment under blinding and around building complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Laid horizontally m2 25 B Laid vertically m2 55 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - CONCRETE WORK - Page No. 3.1 BILL NO. 04 - CONCRETE WORK - Page No. 3.1 Code Description Note: DIVISION 03 - CONCRETE WORKS Note: IN ACCORDANCE WITH SPECIFICATIONS AND DRAWINGS Note: Sub Structure Note: Plain concrete, C20/25 compressive strength with ordinary Portland cement, GGBS, including shuttering, additives, plasticizers, curing, vibrating, and all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A 100 mm thick Blinding m3 4 Code Description Note: Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating, and all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Foundation m3 3 C Neck column m3 1 D Slab on grade m3 3 E Ground beam m3 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - CONCRETE WORKS (Cont'd)- Page No. 3.2 BILL NO. 04 - CONCRETE WORKS (Cont'd)- Page No. 3.2 Code Description Note: DIVISION 03 - CONCRETE WORKS ( CONT`D) Note: Sub Structure (Cont`d) Note: Steel reinforcement Note: High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420 N/mm2 for shear design complete in accordance with specification and drawing Code Description Remarks Unit of Measurement Quantity A 10 mm diameter kg 253 B 12 mm diameter kg 145 C 16 mm diameter kg 427 Code Description Note: Shuttering Note: Temporary shuttering, standard finish complete in accordance with specifications and drawing Code Description Remarks Unit of Measurement Quantity D To sides of foundation m2 9 E To sides of neck columns m2 7 F To sides of ground beams m2 18 Code Description Note: Super Structure Note: Reinforced concrete, C45 fc' =36Mpa at 28 days cylinder compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating, and all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity G Columns m3 2 H Slabs m3 3 J Beams m3 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - CONCRETE WORKS (Cont'd)- Page No. 3.3 BILL NO. 04 - CONCRETE WORKS (Cont'd)- Page No. 3.3 Code Description Note: DIVISION 03 - CONCRETE WORKS ( CONT`D) Note: Super Structure (Cont'd) Note: Steel reinforcement Note: High grade steel deformed bar reinforcement 460 Mpa according to BS 4449 complete in accordance with specification and drawing Code Description Remarks Unit of Measurement Quantity A 10 mm diameter kg 225 B 12 mm diameter kg 615 C 16 mm diameter kg 397 Code Description Note: Shuttering Note: Temporary shuttering, standard finish complete in accordance with specifications and drawing Code Description Remarks Unit of Measurement Quantity D To sides of columns m2 21 E To sides and soffits of slabs m2 47 F To sides and soffits of beams m2 17 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - CONCRETE WORKS (Cont'd)- Page No. 3.5 BILL NO. 04 - CONCRETE WORKS (Cont'd)- Page No. 3.5 Code Description Note: DIVISION 03 - CONCRETE WORKS ( CONT`D) Note: CONCRETE SUNDRIES Code Description Remarks Unit of Measurement Quantity A Allow for all joints including isolation, control, construction and contraction joints or the like as required all in accordance with the specifications and drawings Item 1 B Allow for equipment base concrete as required all in accordance with the specifications and drawings Item 1 C Allow for structural opening for MEP services and networks throw slabs, beams, columns and foundations all in accordance with the specifications and drawings Item 1 D Allow for all builders work in connection with the whole of MEP works including all manholes, sumps, pits, etc. Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - MASONARY WORKS - Page No. 4.1 BILL NO. 04 - MASONARY WORKS - Page No. 4.1 Code Description Note: DIVISION 04 - MASONRY WORKS Note: External Block Work Note: External concrete block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Ref.W-05, 200mm thick m2 50 B Ref.W-04, 300mm thick m2 26 Code Description Note: Internal Block Work Note: Internal concrete block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C Ref.W-06, 100mm thick m2 9 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - MASONARY WORKS - Page No. 4.2 BILL NO. 04 - MASONARY WORKS - Page No. 4.2 Code Description Note: DIVISION 04 - MASONRY WORKS (CONT`D) Note: Masonry Sundries Code Description Remarks Unit of Measurement Quantity A Allow for control joint complete in accordance with specification and drawing Item 1 B Allow for fire sealant complete in accordance with specification and drawing Item 1 C Allow for all opening and builder works for all MEP services in connection with masonry works all complete in accordance with specification and drawing Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - METAL WORK - Page No. 5.1 BILL NO. 04 - METAL WORK - Page No. 5.1 Code Description Note: DIVISION 05 - METAL WORKS Note: Non Structural Metal Work Note: Aluminium Powder Coated Canopy Note: Supply and install Aluminium powder coated canopy, including steel box, galvanized beams supportive system, finishes, all fittings, accessories and fixings complete in accordance with specifications and drawings (Design by specialist) Code Description Remarks Unit of Measurement Quantity A Aluminium Canopy, L shaped size 8200x1325mm No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - THERMAL & MOISTURE PROTECTION - Page No. 7.1 BILL NO. 04 - THERMAL & MOISTURE PROTECTION - Page No. 7.1 Code Description Note: DIVISION 07 - THERMAL & MOISTURE PROTECTION Note: Substructure Waterproofing Note: Supply and apply 1000guage polyethylene separation sheet, complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity A Laid horizontally, under slab on grade m2 20 Code Description Note: Supply and apply 1 layer of 4mm THK. each waterproofing membrane torch applied, complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity B Laid horizontally, under and above foundation m2 14 C Laid horizontally, under ground beam m2 5 D Laid vertically, side foundation m2 9 E Laid vertically, column neck m2 7 F Laid vertically, side ground beam m2 18 Code Description Note: Protection Note: Supply and install seal tight protection board complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity G Laid vertically & horizontally, 6mm thick m2 41 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - THERMAL & MOISTURE PROTECTION - Page No. 7.2 BILL NO. 04 - THERMAL & MOISTURE PROTECTION - Page No. 7.2 Code Description Note: DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D) Note: Roof Waterproofing System Note: Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings Note: Laid Horizontally Code Description Remarks Unit of Measurement Quantity A Roof cement tiles, Size 300x300 m2 12 B Polyflex combo-top coat (1000 mic thick), sri > 78 as per green building regulation m2 12 C SBR bonding agent m2 12 D Concrete screed (26n/mm 2-350opc, 80mm ave. thickness) m2 12 E Polyfab filter membrane ( 1200mic thick) m2 12 F Polytex liquid U.V. protection coat ( 600mic thick) m2 12 G Polyurethane foam of thickness 110mm with 45-50kg/m 3density m2 12 H Light weight foam concrete, 50mm mni thickness. sloped to drain 2% m2 12 J Polybond bonding agent m2 12 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - THERMAL & MOISTURE PROTECTION - Page No. 7.3 BILL NO. 04 - THERMAL & MOISTURE PROTECTION - Page No. 7.3 Code Description Note: DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D) Note: Roof Waterproofing System ( Cont`d) Note: Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings (Cont`d) Note: Laid Vertically Code Description Remarks Unit of Measurement Quantity A Brush applied polytex -hr top coat ( 1000mic thick) sri > 78 m 14 B Fabric reinforcement m 14 C Angle Fillet, 100x100mm m 14 D Polybond bonding agent m 14 E polyfab filter membrane (1200mic thick) m 14 F Polyurethane foam of thickness 110mm with 45-50kg/m 3density m 14 G Aluminum flashing m 14 Code Description Note: Sundries Code Description Remarks Unit of Measurement Quantity H Allow for waterproofing dressing around rain water outlet Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - DOORS & WINDOWS - Page No. 8.1 BILL NO. 04 - DOORS & WINDOWS - Page No. 8.1 Code Description Note: DIVISION 08 - DOORS AND WINDOWS Note: External Doors Note: Wooden Doors Note: Supply and install wooden doors including solid wood frame with plastic laminated finish, ironmongeries, architrave, decorations, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity A Ref.WD-05, single leaf door, size 1250 x 2200mm No 1 Code Description Note: Aluminium Gate Note: Supply and install aluminium gate with powder coated finish included finish, frame, ironmongeries, decorations, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity B Ref. MD-01, size 7200 x 2800mm high, Sliding No 1 C Ref. MD-02, size 1250 x 2800mm high No 1 Code Description Note: Aluminum Windows Note: Supply and install glazing aluminum windows with powder coated finish including, sub-frame, ironmongeries, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity D Ref-WN01, Size 2400 x 1200 mm No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - DOORS & WINDOWS - Page No. 8.2 BILL NO. 04 - DOORS & WINDOWS - Page No. 8.2 Code Description Note: DIVISION 08 - DOORS AND WINDOWS Note: Internal Doors Note: Wooden Doors Note: Supply and install wooden doors including solid wood frame with plastic laminated finish, ironmongeries, architrave, decorations, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity A Ref.WD-08, single leaf door, size 1250 x 2200mm No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - FINISHES - Page No. 9.1 BILL NO. 04 - FINISHES - Page No. 9.1 Code Description Note: DIVISION 09 - FINISHES Note: Internal Finishes Note: Backgrounds Note: Floor Screed Note: Supply and install Cement and sand screed with self levelling compound; including sand filling, surface preparation, and all necessary works; complete all in according to drawings and specifications Code Description Remarks Unit of Measurement Quantity A To receive porcelain tiles m2 16 Code Description Note: Plaster Note: Supply and install 20mm thick cement and sand plaster to block or concrete walls and columns including metal lath and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B To receive wall paint m2 47 C To receive wall tile m2 19 Code Description Note: Supply and install cement sand plaster to soffits including all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity D To receive paint finish m2 15 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - FINISHES - Page No. 9.2 BILL NO. 04 - FINISHES - Page No. 9.2 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: Internal Finishes Note: Supply and install porcelain tiles flooring including bedding materials, matching colored grout, polished, jointing floor transition strips and acoustic underlay (where required) and all necessary works complete in accordance with specifications and drawings (Screed measured separately) Code Description Remarks Unit of Measurement Quantity A Ref-FF01, porcelain tiles, Size 600x600mm m2 13 Code Description Note: Supply and install Unglazed non skid Porcelain tiles flooring including bedding materials, matching colored grout, polished, jointing floor transition strips and acoustic underlay (where required) and all necessary works complete in accordance with specifications and drawings (Screed measured separately) Code Description Remarks Unit of Measurement Quantity B Ref-FF02, porcelain tiles, Size 300x300mm m2 3 Code Description Note: Threshold Note: Supply and install marble threshold including bedding materials, waterproofing, grouting, jointing and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C 200mm wide, 30mm thick m 1 D 300mm wide, 30mm thick m 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - FINISHES - Page No. 9.3 BILL NO. 04 - FINISHES - Page No. 9.3 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: Internal Finishes (Cont'd) Note: Skirting Note: Supply and install porcelain tile skirting including backing, jointing and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Ref-Sk01, high heavy duty porcelain tiles skirting, 100mm m 16 Code Description Note: Walls Finishes Note: Supply and install porcelain wall tiling fixed with approved adhesive including backing, jointing, corner trim and all necessary works complete in accordance with specifications and drawings (Plaster measured separately) Code Description Remarks Unit of Measurement Quantity B Ref-WF-02, porcelain tiles, Size 300 x 600mm m2 19 Code Description Note: Painting and Decoration Note: Supply and install emulation high quality 100 % pure anti fungal & anti microbial (bacteria) highly washable paint , Matt finish, including backing, jointing, corner trim and all necessary works complete in accordance with specifications and drawings (Plaster measured separately) Code Description Remarks Unit of Measurement Quantity C Ref-WF-01, Emulation paint m2 47 Code Description Note: Supply and install emulation paint over including all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity D Ref-CL-03 m2 15 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - FINISHES - Page No. 9.4 BILL NO. 04 - FINISHES - Page No. 9.4 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: External Finishes Note: Backgrounds Note: Plaster Note: Supply and install cement and sand plaster to block or concrete walls and columns including metal lath and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A To external block or concrete walls and columns, to receive paint finish m2 146 Code Description Note: Painting and Decoration Note: Supply and apply paint finish including surface preparation, primer coat, final coat and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B To plastered walls, Ref. EF 01 m2 146 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - ACCESSORIES - Page No. 10.1 BILL NO. 04 - ACCESSORIES - Page No. 10.1 Code Description Note: DIVISION 10 - ACCESSORIES Note: Sanitary Fixture & Accessories Note: Supply and install sanitary fixtures and accessories including fittings, fixings, connections and all necessary works complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity A Ref. TB-009, Wall mounted soap dispenser No. 1 B Ref. FC-001 No. 1 C Ref. LAV-003 No. 1 D Ref. WC-003, Wall mounted water closet No. 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 -MECH INSTALLATION - Page No. 15.1 BILL NO. 04 -MECH INSTALLATION - Page No. 15.1 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS Note: Rainwater, soil, waste, and vent pipework installations complete in accordance with specifications and drawings Note: Pipework Note: Above ground uPVC pipework including fittings, accessories, insect screen, and all necessary works complete in accordance with drawings and specifications Code Description Remarks Unit of Measurement Quantity A 50mm diameter m 1 B 82mm diameter m 4 C 110mm diameter m 1 Code Description Note: Under ground uPVC pipework including excavation, backfilling, warning tap, fittings, accessories, and all necessary works complete in accordance with drawings and specifications Code Description Remarks Unit of Measurement Quantity D 50mm diameter m 3 E 82mm diameter m 1 F 110mm diameter m 2 Code Description Note: Fittings, complete in accordance with drawings and specifications Note: Rain Water Drain Code Description Remarks Unit of Measurement Quantity G Ref. RWO, 110mm diameter No 1 Code Description Note: Floor Drain Code Description Remarks Unit of Measurement Quantity H Ref. FD, 150x150mm No 1 Code Description Note: Floor Cleanout Code Description Remarks Unit of Measurement Quantity J Ref. FCO 110mm diameter No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 -MECH INSTALLATION (Cont'd) - Page No. 15.2 BILL NO. 04 -MECH INSTALLATION (Cont'd) - Page No. 15.2 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Fittings, complete in accordance with drawings and specifications (Cont'd) Note: Vent Cowl Code Description Remarks Unit of Measurement Quantity A Size 82mm No 1 B Size 110mm No 1 Code Description Note: Domestic Hot and Cold Water Installation Note: Cold Water Supply System Note: Supply and install cold water PPR pipe works including necessary, fittings, valves and accessories, and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C 20mm diameter m 23 Code Description Note: Hot Water Supply System Note: Supply and install hot water PPR pipe works with insulation including necessary, fittings, valves and accessories, and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity D 20mm diameter m 3 Code Description Note: Isolating Valves Code Description Remarks Unit of Measurement Quantity E 20mm diameter No 2 Code Description Note: Water Hammer Arrestor Code Description Remarks Unit of Measurement Quantity F 20mm diameter No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 -MECH INSTALLATION (Cont'd) - Page No. 15.3 BILL NO. 04 -MECH INSTALLATION (Cont'd) - Page No. 15.3 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Domestic Hot and Cold Water Installation (Cont'd) Note: Electrical Water Heater Note: Supply, install, test and commission electrical water heater complete including all fittings and accessories complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity A Ref. EWH 30l liters No 1 Code Description Note: Fire Fighting System Note: Fire Extinguisher Note: Supply install test and commission fire extinguisher including but not limited to wall fixing frame and hanger and all required components and accessories as per drawings, specifications and civil defense regulations. Code Description Remarks Unit of Measurement Quantity B 5 Kg dry CO2 fire extinguisher No 1 Code Description Note: Air Conditioning System and Ventilation Installation Note: Ductwork Note: Design, fabrication and installation of galvanized sheet metal ductwork including circular duct work, supports, fittings and accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity C Supply duct Kg 25 Code Description Note: Internal Duct Insulation Note: Supply and install internal insulation for duct and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity D For supply duct m2 4 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 -MECH INSTALLATION (Cont'd) - Page No. 15.4 BILL NO. 04 -MECH INSTALLATION (Cont'd) - Page No. 15.4 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D) Note: Air Conditioning System and Ventilation Installation (Cont'd) Note: DX Unit Note: Supply, install, test and commission DX unit cooling only including but not limited to indoor & outdoor units, vibration isolation, control wiring, flexible connectors, integral control, hanger, supports, filters, sleeves, condensate piping and all required accessories as per drawings and specifications. Code Description Remarks Unit of Measurement Quantity A Ref. 03-FCU-01 / CU/03-FCU-01, air side 224 L/s No 1 Code Description Note: Diffusers, Grills, Dampers, Liner diffusers Note: Supply and return air diffuser Code Description Remarks Unit of Measurement Quantity B Ref. SD 375x375mm No 1 C Ref. RD 375x375mm No 1 Code Description Note: Building Management System (BMS) Code Description Remarks Unit of Measurement Quantity D Supply, install, test and commissioning of Building management system including points, wires, conduits, and all necessary works complete in accordance with specifications and drawings Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 -MECH INSTALLATION (Cont'd) - Page No. 15.5 BILL NO. 04 -MECH INSTALLATION (Cont'd) - Page No. 15.5 Code Description Note: Sundry / General Items Code Description Remarks Unit of Measurement Quantity A Allow for permits, connection and inspection fees associated with mechanical installations by utility and statutory authorities Item 1 B Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings Item 1 C Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment Item 1 D Allow for setting out the works, marking positions of holes, mortises, chases or the like Item 1 E Allow for testing and commissioning and submission of test certificates Item 1 F Allow for all identification labels, plates, charts and identification of plant, equipment, cable, isolators and the like Item 1 G Allow for preparing schedule of manufacturers recommended tools and spare parts for each piece of equipment Item 1 H Allow for the provision of operating/maintenance manuals Item 1 J Allow for providing shop and coordination drawings Item 1 K Allow for domestic water piping, sterilization and disinfections after commissioning Item 1 L Allow for flushing chilled water system pipe work with water and establishment of rust inhibitor before commissioning Item 1 M Allow for fire stopping in accordance with the drawings, specification and local authorities requirements Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1 BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS Note: Power System installations Note: Final Distribution Boards Note: Supply, install, test, commission and maintain Final Distribution boards and terminations including bus bars, breakers, indicators, all interconnecting cables, wires termination and trays from main board, and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Final distribution boards, DB-GU No 1 Code Description Note: Power Distribution Note: Supply and install the following power fittings including all necessary accessories and connections to wiring and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity B 13A Twin switched socket No 3 C 13A Switched spur outlet No 1 D 13A Unswitched spur outlet No 1 E 20A double pole switch No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2 BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Power System Installations (Cont'd) Note: Power point Note: Supply and install wiring and conduit in concealed installation including cable trays / trucking, access box with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A Power points No 6 Code Description Note: Isolating Switch Note: Supply and install isolating switch including all interconnecting and terminations and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity B Isolator three phase 32A IP65 No 1 Code Description Note: Internal Lighting Note: Supply and install lighting including all necessary accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C Lighting fixture, type S2 No 1 D Ditto, type S3 No 1 E Ditto, type W1 No 1 F Ditto, type L1 No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3 BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Power System Installations (Cont'd) Note: Internal Lighting Points Note: Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A Internal Lighting points No 5 Code Description Note: Switches Note: Supply, install, test, commission switches including all necessary accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Two gang, one way lighting switch 20A No 1 C Three gang, two way lighting switch 20A, W/P No 1 Code Description Note: Lighting switch Point Note: Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity D Lighting switch points No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4 BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Emergency and Exit Lighting System Note: Supply, install, test, commission the following emergency and exit light fittings, including ceiling rose, heat resistance, flexible cable, lamps, electronic control gear, suspensions, connections to permanent wiring system in accordance with Specification and drawings Code Description Remarks Unit of Measurement Quantity A Self-contained 1x8w emergency light with built-in battery (3h duration ), surface-mounted, non-maintained No 1 Code Description Note: Emergency lighting points Note: Supply and install wiring and conduit in concealed installation including cable trays / trunking, with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity B Emergency lighting points No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5 BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Fire Alarm System Note: Supply, install, test, commission and maintain the complete Analogue addressable fire Alarm & evacuation system including cabling, wiring conduit, cable tray, trunking, termination and power connections and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Intelligent optical smoke detector and standard base No 1 B Fire alarm sounder or horn W/P No 1 C Fire alarm junction box No 1 D Dual input module No 1 E Monitoring module No 1 Code Description Note: Earthing protection system Note: Supply, install, test and commissioning of earthing protection system including earth pits, conductors, bars ,bonds and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity F Earthing protection Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6 BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Sundry / General Items Code Description Remarks Unit of Measurement Quantity A Allow for permits, connection and inspection fees associated with electrical installations by utility and statutory authorities Item 1 B Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings Item 1 C Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment Item 1 D Allow for setting out the works, marking positions of holes, mortises, chases or the like Item 1 E Allow for testing and commissioning and production of test certificates Item 1 F Allow for all identification labels, plates, charts and identification of plant, equipment, cable, switches and the like Item 1 G Allow for the provision of operating / maintenance manuals Item 1 H Allow for providing shop and coordination drawings Item 1 J Allow for instructing selected employer's personnel on all aspects of the operation of systems and equipment Item 1 K Supply and handover to the client all tools and equipment in accordance with the specification Item 1 L Allow for fire stopping in accordance with the drawings specification and local authorities requirements Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - SITE WORK - Page No. 2.1 BILL NO. 05 - SITE WORK - Page No. 2.1 Code Description Note: DIVISION 02 - SITE WORKS Note: Site Preparation Code Description Remarks Unit of Measurement Quantity A Site Clearance, including removal of rubbish, debris, vegetation, within the designated work area complete accordance with the specifications and drawings m2 102 Code Description Note: Excavation Note: Excavation from existing level to bottom of foundation levels complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Bulk Excavation m3 40 C Pit Excavation m3 39 D Trench Excavation m3 59 Code Description Note: Backfilling Code Description Remarks Unit of Measurement Quantity E Backfilling, including compaction in layer complete in accordance with specifications and drawings m3 83 Code Description Note: Disposal of Material Arising From Excavations Code Description Remarks Unit of Measurement Quantity F Remove surplus excavated material from site to approved location complete in accordance with specifications and drawings m3 55 Code Description Note: Road base Code Description Remarks Unit of Measurement Quantity G Road base, including compaction in layer complete in accordance with specifications and drawings m3 6 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - SITE WORK (CONT'D) - Page No. 2.2 BILL NO. 05 - SITE WORK (CONT'D) - Page No. 2.2 Code Description Note: DIVISION 02 - SITE WORKS(CONT'D) Note: Anti - Termite Treatment Note: Allow for anti termite treatment under blinding and around building complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Laid horizontally m2 102 B Laid vertically m2 128 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - CONCRETE WORK - Page No. 3.1 BILL NO. 05 - CONCRETE WORK - Page No. 3.1 Code Description Note: DIVISION 03 - CONCRETE WORKS Note: IN ACCORDANCE WITH SPECIFICATIONS AND DRAWINGS Note: Sub Structure Note: Plain concrete, C20/25 compressive strength with ordinary Portland cement, GGBS, including shuttering, additives, plasticizers, curing, vibrating, and all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A 100 mm thick Blinding m3 11 Code Description Note: Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating, and all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Foundation m3 8 C Columns neck m3 1 D Slab on grade m3 13 E Ground beams m3 9 F Trench wall m3 3 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - CONCRETE WORKS (Cont'd)- Page No. 3.2 BILL NO. 05 - CONCRETE WORKS (Cont'd)- Page No. 3.2 Code Description Note: DIVISION 03 - CONCRETE WORKS ( CONT`D) Note: Sub Structure (Cont`d) Note: Steel reinforcement Note: High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420 N/mm2 for shear design complete in accordance with specification and drawing Code Description Remarks Unit of Measurement Quantity A 10 mm diameter kg 1,506.28 B 12 mm diameter kg 1,318.7 C 16 mm diameter kg 659 Code Description Note: Shuttering Note: Temporary shuttering, standard finish complete in accordance with specifications and drawing Code Description Remarks Unit of Measurement Quantity D To sides of foundation m2 17 E To sides of columns neck m2 13 F To side of ground beam m2 76 G To side of trench wall m2 79 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - CONCRETE WORKS (Cont'd)- Page No. 3.3 BILL NO. 05 - CONCRETE WORKS (Cont'd)- Page No. 3.3 Code Description Note: DIVISION 03 - CONCRETE WORKS ( CONT`D) Note: Super Structure Note: Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating, and all necessary works, complete in accordance with specifications and drawings (Cont'd) Code Description Remarks Unit of Measurement Quantity A Columns m3 4 B Slabs m3 22 C Beams m3 5 Code Description Note: Steel reinforcement Note: High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420 N/mm2 for shear design complete in accordance with specification and drawing Code Description Remarks Unit of Measurement Quantity D 10 mm diameter kg 573.85 E 12 mm diameter kg 2,531.49 F 16 mm diameter kg 1,095.08 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - CONCRETE WORKS (Cont'd)- Page No. 3.4 BILL NO. 05 - CONCRETE WORKS (Cont'd)- Page No. 3.4 Code Description Note: DIVISION 03 - CONCRETE WORKS ( CONT`D) Note: Super Structure Note: Shuttering Note: Temporary shuttering, standard finish complete in accordance with specifications and drawing Code Description Remarks Unit of Measurement Quantity A To sides of columns m2 44 B To sides and soffits of slabs m2 86 C To sides and soffits of beams m2 53 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - CONCRETE WORKS (Cont'd)- Page No. 3.5 BILL NO. 05 - CONCRETE WORKS (Cont'd)- Page No. 3.5 Code Description Note: DIVISION 03 - CONCRETE WORKS ( CONT`D) Note: CONCRETE SUNDRIES Code Description Remarks Unit of Measurement Quantity A Allow for all joints including isolation, control, construction and contraction joints or the like as required all in accordance with the specifications and drawings Item 1 B Allow for equipment base concrete as required all in accordance with the specifications and drawings Item 1 C Allow for structural opening for MEP services and networks throw slabs, beams, columns and foundations all in accordance with the specifications and drawings Item 1 D Allow for all builders work in connection with the whole of MEP works including all manholes, sumps, pits, etc. Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - MASONARY WORKS - Page No. 4.1 BILL NO. 05 - MASONARY WORKS - Page No. 4.1 Code Description Note: DIVISION 04 - MASONRY WORKS Note: External Block Work Note: External CMU hollow normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Ref.W-04, 200mm thick m2 130 Code Description Note: Internal CMU hollow normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Ref.W-04, 200mm thick m2 16 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - MASONARY WORKS - Page No. 4.2 BILL NO. 05 - MASONARY WORKS - Page No. 4.2 Code Description Note: DIVISION 04 - MASONRY WORKS Note: Masonry Sundries Code Description Remarks Unit of Measurement Quantity A Allow for control joint complete in accordance with specification and drawing Item 1 B Allow for fire sealant complete in accordance with specification and drawing Item 1 C Allow for all opening and builder works for all MEP services in connection with masonry works all complete in accordance with specification and drawing Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - METAL WORK - Page No. 5.1 BILL NO. 05 - METAL WORK - Page No. 5.1 Code Description Note: DIVISION 05 - METAL WORKS Note: Non Structural Metal Work Note: Ladders Note: Supply and install galvanized steel ladder including rungs, side rails, safety cage, frame, steel brackets, supports, anchors, bolts, fixing, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Access cat ladder, 800x5560 mm height No 1 Code Description Note: Aluminum Louvers Note: Supply and install aluminum louvers decorative powder coated aluminum screens, decorative powder coated aluminum frame and steel support including all fittings, accessories and fixings complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Ref. AL-03, Aluminum louvers, size 3900mm x 2150mm No 1 Code Description Note: Trench Grating Note: Supply and install trench grating including fixing in position, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C Trench Grating m2 22 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - THERMAL & MOISTURE PROTECTION - Page No. 7.1 BILL NO. 05 - THERMAL & MOISTURE PROTECTION - Page No. 7.1 Code Description Note: DIVISION 07 - THERMAL & MOISTURE PROTECTION Note: Substructure Waterproofing Note: Supply and apply 1000guage polyethylene separation sheet, complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity A Laid horizontally, under slab on grade m2 87 Code Description Note: Supply and apply 1 layer of 4mm THK. each waterproofing membrane torch applied, complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity B Laid horizontally, under and above foundation m2 38 C Laid horizontally, under ground beam m2 18 D Laid vertically, side foundation m2 17 E Laid vertically, column neck m2 13 F Laid vertically, side ground beam m2 76 G Laid vertically, side trench wall m2 39 Code Description Note: Protection board Note: Supply and install seal tight protection board complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity H Laid vertically & horizontally, 6mm thick m2 145 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - THERMAL & MOISTURE PROTECTION - Page No. 7.2 BILL NO. 05 - THERMAL & MOISTURE PROTECTION - Page No. 7.2 Code Description Note: DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT'D) Note: Roof Waterproofing System Note: Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings Note: Laid Horizontally Code Description Remarks Unit of Measurement Quantity A Roof cement tiles, Size 300x300 m2 78 B Polyflex combo-top coat (1000 mic thick), sri > 78 as per green building regulation m2 78 C SBR bonding agent m2 78 D Concrete screed (26n/mm 2-350opc, 80mm ave. thickness) m2 78 E Polyfab filter membrane ( 1200mic thick) m2 78 F Polytex liquid U.V. protection coat ( 600mic thick) m2 78 G Polyurethane foam of thickness 110mm with 45-50kg/m 3density m2 78 H Light weight foam concrete, 50mm mni thickness. sloped to drain 2% m2 78 J Polybond bonding agent m2 78 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - THERMAL & MOISTURE PROTECTION - Page No. 7.3 BILL NO. 05 - THERMAL & MOISTURE PROTECTION - Page No. 7.3 Code Description Note: DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT'D) Note: Roof Waterproofing System ( Cont`d) Note: Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings (Cont`d) Note: Laid Vertically Code Description Remarks Unit of Measurement Quantity A Brush applied polytex -hr top coat ( 1000mic thick) sri > 78 m 78 B Fabric reinforcement m 39 C Angle Fillet, 100x100mm m 39 D Polybond bonding agent m 39 E polyfab filter membrane ( 1200mic thick) m 39 F Polyurethane foam of thickness 110mm with 45-50kg/m 3density m 39 G Aluminum flashing m 39 Code Description Note: Sundries Code Description Remarks Unit of Measurement Quantity H Allow for waterproofing dressing around rain water outlet Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - DOORS & WINDOWS - Page No. 8.1 BILL NO. 05 - DOORS & WINDOWS - Page No. 8.1 Code Description Note: DIVISION 08 - DOORS AND WINDOWS Note: External Hollow Metal Doors Note: Aluminium Louver Doors Note: Supply and install aluminium louver doors with powder coated finish including frame, ironmongeries, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity A Ref AL01, size 3050x2750mm No 1 B Ref AL02, size 1500x2490mm No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - FINISHES - Page No. 9.1 BILL NO. 05 - FINISHES - Page No. 9.1 Code Description Note: DIVISION 09 - FINISHES Note: Internal Finishes Note: Backgrounds Note: Floor Screed Note: Supply and install cement and sand screed with self levelling compound; including sand filling, surface preparation, and all necessary works; all in according to drawings and specifications Code Description Remarks Unit of Measurement Quantity A To receive Epoxy Paint m2 78 Code Description Note: Plaster Note: Supply and install 20mm thick cement and sand plaster to block or concrete walls and columns including metal lath and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B To receive paint finish m2 53 Code Description Note: Supply and install cement sand plaster to soffits including all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity C To receive paint finish m2 78 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - FINISHES - Page No. 9.2 BILL NO. 05 - FINISHES - Page No. 9.2 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: Internal Finishes (Cont'd) Note: Floor Finishes Note: Supply and apply Heavy duty free solvent epoxy coating including all necessary works complete in accordance with specifications and drawings (Screed measured separately) Code Description Remarks Unit of Measurement Quantity A Ref-FF04 m2 78 Code Description Note: Skirting Note: Supply and apply epoxy skirting including surface preparation, primer coat, final coat and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Ref-Sk02 m 46 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - FINISHES - Page No. 9.3 BILL NO. 05 - FINISHES - Page No. 9.3 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: Internal Finishes (Cont'd) Note: Painting and Decoration Note: Supply and apply paint finish including surface preparation, primer coat, final coat and all necessary works complete in accordance with specifications and drawings (Plaster measured separately) Code Description Remarks Unit of Measurement Quantity A To walls, paint, Ref-WF01 m2 127 B To plastered soffits, paint, Ref-CL03 m2 78 Code Description Note: External Finishes Note: Plaster Note: Supply and install cement and sand plaster to block or concrete walls and columns including metal lath, grooves and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C To external block or concrete walls and columns, to receive paint finish m2 229 Code Description Note: Painting and Decoration Note: Supply and apply paint finish including surface preparation, primer coat, final coat and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity D To plastered walls, paint m2 229 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 -MECH INSTALLATION - Page No. 15.1 BILL NO. 05 -MECH INSTALLATION - Page No. 15.1 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS Note: Rainwater, soil, waste, and vent pipework installations complete in accordance with specifications and drawings Note: Pipework Note: Above ground uPVC pipework including fittings, accessories, insect screen, and all necessary works complete in accordance with drawings and specifications Code Description Remarks Unit of Measurement Quantity A 110mm diameter m 9 Code Description Note: Fittings, complete in accordance with drawings and specifications Note: Rain Water Drain Code Description Remarks Unit of Measurement Quantity B Ref. RWO, 110mm diameter No 2 Code Description Note: Fire Fighting System Note: Fire Extinguisher Note: Supply install test and commission fire extinguisher including but not limited to wall fixing frame and hanger and all required components and accessories as per drawings, specifications and civil defense regulations. Code Description Remarks Unit of Measurement Quantity C 2 Kg dry CO2 fire extinguisher No 1 D 12 Kg dry CO2 trolly type No 1 Code Description Note: Building Management System (BMS) Code Description Remarks Unit of Measurement Quantity E Supply, install, test and commissioning of Building management system including points, wires, conduits, and all necessary works complete in accordance with specifications and drawings Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 -MECH INSTALLATION (Cont'd) - Page No. 15.2 BILL NO. 05 -MECH INSTALLATION (Cont'd) - Page No. 15.2 Code Description Note: Sundry / General Items Code Description Remarks Unit of Measurement Quantity A Allow for permits, connection and inspection fees associated with mechanical installations by utility and statutory authorities Item 1 B Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings Item 1 C Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment Item 1 D Allow for setting out the works, marking positions of holes, mortises, chases or the like Item 1 E Allow for testing and commissioning and submission of test certificates Item 1 F Allow for all identification labels, plates, charts and identification of plant, equipment, cable, isolators and the like Item 1 G Allow for preparing schedule of manufacturers recommended tools and spare parts for each piece of equipment Item 1 H Allow for the provision of operating/maintenance manuals Item 1 J Allow for providing shop and coordination drawings Item 1 K Allow for domestic water piping, sterilization and disinfections after commissioning Item 1 L Allow for fire stopping in accordance with the drawings, specification and local authorities requirements Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1 BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS Note: Capacitor Bank Panel Note: Supply, install, test and commission Multi step automatic switching capacitor bank with reactive power regulator including ,MCCB's, terminations, supports, accessories, and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Capacitor bank panel, 300 KVAR No 1 Code Description Note: Main &Sub Main Distribution Boards Note: Supply, install, test, commission, and maintain main and sub-main distribution boards and terminations, including bus bars, breakers, indicators, meters, all interconnecting cables, wires termination, energy monitoring meters, and trays from the main board, and all necessary works complete in accordance with specification and drawings Note: Main Distribution Boards Code Description Remarks Unit of Measurement Quantity B Main distribution boards, ref LVP-03 No 1 Code Description Note: Sub Main Distribution Boards Code Description Remarks Unit of Measurement Quantity C Sub main distribution boards, ref SMDB-SERV No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2 BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Power System Installations (Cont'd) Note: Final Distribution Boards Note: Supply, install, test, commission and maintain Final Distribution boards and terminations including bus bars, breakers, indicators, all interconnecting cables, wires termination and trays from main board, and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Final distribution boards, DB-SS No 1 B Ditto, DB-LV No 1 Code Description Note: Cables B Low Voltage cables including ducts, glands, connections, conduits, termination, trays and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A 2C 6mm2 XLPE/SWA/CU/PVC+ 1C.6mm2 ECC m 15 B 4C 6mm2 XLPE/SWA/PVC+ 1C.6mm2 PVC/ECC/CU m 11 C 4C 70mm2 XLPE/SWA/PVC+ 1C.35mm2 CPC m 15 D 2x4C 300mm2 XLPE/SWA/PVC+ 2x1C.150mm2 CPC m 9 Code Description Note: Power Distribution Note: Supply and install the following power fittings including all necessary accessories and connections to wiring and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity E 13A Single switched socket No 2 F 13A Twin switched socket No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3 BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Power System Installations (Cont'd) Note: Power point Note: Supply and install wiring and conduit in concealed installation including cable trays / trucking, access box with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A Power points No 4 Code Description Note: Isolating Switch Note: Supply and install isolating switch including all interconnecting and terminations and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity B Isolator single phase 32A, weather proof No 2 Code Description Note: Internal Lighting Note: Supply and install lighting including all necessary accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C Lighting fixture, type W1 No 2 D Ditto, type B1 No 15 Code Description Note: Internal Lighting Points Note: Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity E Internal Lighting points No 17 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4 BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Power System Installations (Cont'd) Note: Switches Note: Supply, install, test, commission switches including all necessary accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Two gang, one way lighting switch 20A No 1 B Three gang, one way lighting switch 20A No 1 Code Description Note: Lighting switch Point Note: Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity Code / Note Title Lighting switch points No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5 BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Emergency and Exit Lighting System Note: Supply, install, test, commission the following emergency and exit light fittings, including ceiling rose, heat resistance, flexible cable, lamps, electronic control gear, suspensions, connections to permanent wiring system in accordance with Specification and drawings Code Description Remarks Unit of Measurement Quantity A 1x4w LED, self-contained non-maintained type with monitoring module, 3-hour duration back-up battery, IP-54 (type-EL-1) surface mounted No 1 B 1x3w LED, self-contained, maintained exit light, wall-mounted, 3-hour duration back-up battery, IP-54 No 2 Code Description Note: Emergency lighting points Note: Supply and install wiring and conduit in concealed installation including cable trays / trunking, with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity C Emergency lighting points No 3 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6 BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Fire Alarm System Note: Supply, install, test, commission and maintain the complete Analogue addressable fire Alarm & evacuation system including cabling, wiring conduit, cable tray, trunking, termination and power connections and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Addressable optical smoke detector No 1 B Fire alarm junction box No 1 C Multi sensor detector No 2 D Fire alarm sounder with flasher, weather proof No 1 E Manual call point, weather proof No 1 Code Description Note: Earthing protection system Note: Supply, install, test and commissioning of earthing protection system including earth pits, conductors, bars ,bonds and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity F Earthing protection Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.7 BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.7 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Sundry / General Items Code Description Remarks Unit of Measurement Quantity A Allow for permits, connection and inspection fees associated with electrical installations by utility and statutory authorities Item 1 B Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings Item 1 C Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment Item 1 D Allow for setting out the works, marking positions of holes, mortises, chases or the like Item 1 E Allow for testing and commissioning and production of test certificates Item 1 F Allow for all identification labels, plates, charts and identification of plant, equipment, cable, switches and the like Item 1 G Allow for the provision of operating / maintenance manuals Item 1 H Allow for providing shop and coordination drawings Item 1 J Allow for instructing selected employer's personnel on all aspects of the operation of systems and equipment Item 1 K Supply and handover to the client all tools and equipment in accordance with the specification Item 1 L Allow for fire stopping in accordance with the drawings specification and local authorities requirements Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - SITE WORK - Page No. 2.1 BILL NO. 06 - SITE WORK - Page No. 2.1 Code Description Note: DIVISION 02 - SITE WORKS Note: Site Preparation Code Description Remarks Unit of Measurement Quantity A Site Clearance, including removal of rubbish, debris, vegetation, within the designated work area complete accordance with the specifications and drawings m2 17 Code Description Note: Excavation Note: Excavation from existing level to bottom of foundation levels complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Bulk Excavation m3 11 C Pit Excavation m3 3 D Trench Excavation m3 13 Code Description Note: Backfilling Code Description Remarks Unit of Measurement Quantity E Backfilling, including compaction in layer complete in accordance with specifications and drawings m3 17 Code Description Note: Disposal of Material Arising From Excavations Code Description Remarks Unit of Measurement Quantity F Remove surplus excavated material from site to approved location complete in accordance with specifications and drawings m3 10 Code Description Note: Road base Code Description Remarks Unit of Measurement Quantity G Road base, including compaction in layer complete in accordance with specifications and drawings m3 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - SITE WORK (CONT'D) - Page No. 2.2 BILL NO. 06 - SITE WORK (CONT'D) - Page No. 2.2 Code Description Note: DIVISION 02 - SITE WORKS(CONT'D) Note: Anti - Termite Treatment Note: Allow for anti termite treatment under blinding and around building complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Laid horizontally m2 17 B Laid vertically m2 42 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - CONCRETE WORK - Page No. 3.1 BILL NO. 06 - CONCRETE WORK - Page No. 3.1 Code Description Note: DIVISION 03 - CONCRETE WORKS Note: IN ACCORDANCE WITH SPECIFICATIONS AND DRAWINGS Note: Sub Structure Note: Plain concrete, C20/25 compressive strength with ordinary Portland cement, GGBS, including shuttering, additives, plasticizers, curing, vibrating, and all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A 100 mm thick Blinding m3 3 Code Description Note: Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating, and all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Foundation m3 2 C Columns neck m3 1 D Slab on grade m3 2 E Ground beams m3 2 F Trench wall m3 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - CONCRETE WORKS (Cont'd)- Page No. 3.2 BILL NO. 06 - CONCRETE WORKS (Cont'd)- Page No. 3.2 Code Description Note: DIVISION 03 - CONCRETE WORKS ( CONT`D) Note: Sub Structure (Cont`d) Note: Steel reinforcement Note: High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420 N/mm2 for shear design complete in accordance with specification and drawing Code Description Remarks Unit of Measurement Quantity A 10 mm diameter kg 307.76 B 12 mm diameter kg 336.94 C 16 mm diameter kg 241 Code Description Note: Shuttering Note: Temporary shuttering, standard finish complete in accordance with specifications and drawing Code Description Remarks Unit of Measurement Quantity D To sides of foundation m2 7 E To sides of columns neck m2 13 F To side of ground beam m2 22 G To side of trench wall m2 12 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - CONCRETE WORKS (Cont'd)- Page No. 3.3 BILL NO. 06 - CONCRETE WORKS (Cont'd)- Page No. 3.3 Code Description Note: DIVISION 03 - CONCRETE WORKS ( CONT`D) Note: Super Structure Note: Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating, and all necessary works, complete in accordance with specifications and drawings (Cont'd) Code Description Remarks Unit of Measurement Quantity A Columns m3 1 B Slabs m3 2 C Beams m3 1 Code Description Note: Steel reinforcement Note: High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420 N/mm2 for shear design complete in accordance with specification and drawing Code Description Remarks Unit of Measurement Quantity D 10 mm diameter kg 175.48 E 12 mm diameter kg 352.77 F 16 mm diameter kg 337 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - CONCRETE WORKS (Cont'd)- Page No. 3.4 BILL NO. 06 - CONCRETE WORKS (Cont'd)- Page No. 3.4 Code Description Note: DIVISION 03 - CONCRETE WORKS ( CONT`D) Note: Super Structure Note: Shuttering Note: Temporary shuttering, standard finish complete in accordance with specifications and drawing Code Description Remarks Unit of Measurement Quantity A To sides of columns m2 19 B To sides and soffits of slabs m2 12 C To sides and soffits of beams m2 13 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - CONCRETE WORKS (Cont'd)- Page No. 3.5 BILL NO. 06 - CONCRETE WORKS (Cont'd)- Page No. 3.5 Code Description Note: DIVISION 03 - CONCRETE WORKS ( CONT`D) Note: CONCRETE SUNDRIES Code Description Remarks Unit of Measurement Quantity A Allow for all joints including isolation, control, construction and contraction joints or the like as required all in accordance with the specifications and drawings Item 1 B Allow for equipment base concrete as required all in accordance with the specifications and drawings Item 1 C Allow for structural opening for MEP services and networks throw slabs, beams, columns and foundations all in accordance with the specifications and drawings Item 1 D Allow for all builders work in connection with the whole of MEP works including all manholes, sumps, pits, etc. Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - MASONARY WORKS - Page No. 4.1 BILL NO. 06 - MASONARY WORKS - Page No. 4.1 Code Description Note: DIVISION 04 - MASONRY WORKS Note: External Block Work Note: External CMU hollow normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Ref.W-04, 200mm thick m2 36 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - MASONARY WORKS - Page No. 4.2 BILL NO. 06 - MASONARY WORKS - Page No. 4.2 Code Description Note: DIVISION 04 - MASONRY WORKS Note: Masonry Sundries Code Description Remarks Unit of Measurement Quantity A Allow for control joint complete in accordance with specification and drawing Item 1 B Allow for fire sealant complete in accordance with specification and drawing Item 1 C Allow for all opening and builder works for all MEP services in connection with masonry works all complete in accordance with specification and drawing Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - METAL WORK - Page No. 5.1 BILL NO. 06 - METAL WORK - Page No. 5.1 Code Description Note: DIVISION 05 - METAL WORKS Note: Non Structural Metal Work Note: Aluminum Louvers Note: Supply and install aluminum louvers decorative powder coated aluminum screens, decorative powder coated aluminum frame and steel support including all fittings, accessories and fixings complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Aluminum louvers, size 2650mm x 2150mm No 1 Code Description Note: Trench Grating Note: Supply and install trench grating including fixing in position, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Trench Grating m2 3 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - THERMAL & MOISTURE PROTECTION - Page No. 7.1 BILL NO. 06 - THERMAL & MOISTURE PROTECTION - Page No. 7.1 Code Description Note: DIVISION 07 - THERMAL & MOISTURE PROTECTION Note: Substructure Waterproofing Note: Supply and apply 1000guage polyethylene separation sheet, complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity A Laid horizontally, under slab on grade m2 12 Code Description Note: Supply and apply 1 layer of 4mm THK. each waterproofing membrane torch applied, complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity B Laid horizontally, under and above foundation m2 9 C Laid horizontally, under ground beam m2 24 D Laid vertically, side foundation m2 7 E Laid vertically, column neck m2 13 F Laid vertically, side ground beam m2 22 G Laid vertically, side trench wall m2 6 Code Description Note: Protection board Note: Supply and install seal tight protection board complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity H Laid vertically & horizontally, 6mm thick m2 48 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - THERMAL & MOISTURE PROTECTION - Page No. 7.2 BILL NO. 06 - THERMAL & MOISTURE PROTECTION - Page No. 7.2 Code Description Note: DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT'D) Note: Roof Waterproofing System Note: Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings Note: Laid Horizontally Code Description Remarks Unit of Measurement Quantity A Roof cement tiles, Size 300x300 m2 9 B Polyflex combo-top coat (1000 mic thick), sri > 78 as per green building regulation m2 9 C SBR bonding agent m2 9 D Concrete screed (26n/mm 2-350opc, 80mm ave. thickness) m2 9 E Polyfab filter membrane ( 1200mic thick) m2 9 F Polytex liquid U.V. protection coat ( 600mic thick) m2 9 G Polyurethane foam of thickness 110mm with 45-50kg/m 3density m2 9 H Light weight foam concrete, 50mm mni thickness. sloped to drain 2% m2 9 J Polybond bonding agent m2 9 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - THERMAL & MOISTURE PROTECTION - Page No. 7.3 BILL NO. 06 - THERMAL & MOISTURE PROTECTION - Page No. 7.3 Code Description Note: DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT'D) Note: Roof Waterproofing System ( Cont`d) Note: Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings (Cont`d) Note: Laid Vertically Code Description Remarks Unit of Measurement Quantity A Brush applied polytex -hr top coat ( 1000mic thick) sri > 78 m 12 B Fabric reinforcement m 12 C Angle Fillet, 100x100mm m 12 D Polybond bonding agent m 12 E polyfab filter membrane ( 1200mic thick) m 12 F Polyurethane foam of thickness 110mm with 45-50kg/m 3density m 12 G Aluminum flashing m 12 Code Description Note: Sundries Code Description Remarks Unit of Measurement Quantity H Allow for waterproofing dressing around rain water outlet Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - DOORS & WINDOWS - Page No. 8.1 BILL NO. 06 - DOORS & WINDOWS - Page No. 8.1 Code Description Note: DIVISION 08 - DOORS AND WINDOWS Note: External Hollow Metal Doors Note: Aluminium Louver Doors Note: Supply and install aluminium louver doors with powder coated finish including frame, ironmongeries, fixing, fittings and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity A Ref AL01, size 3040x2750mm No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - FINISHES - Page No. 9.1 BILL NO. 06 - FINISHES - Page No. 9.1 Code Description Note: DIVISION 09 - FINISHES Note: Internal Finishes Note: Backgrounds Note: Floor Screed Note: Supply and install cement and sand screed with self levelling compound; including sand filling, surface preparation, and all necessary works; all in according to drawings and specifications Code Description Remarks Unit of Measurement Quantity A To receive Epoxy Paint m2 10 Code Description Note: Plaster Note: Supply and install 20mm thick cement and sand plaster to block or concrete walls and columns including metal lath and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B To receive paint finish m2 33 Code Description Note: Supply and install cement sand plaster to soffits including all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity C To receive paint finish m2 10 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - FINISHES - Page No. 9.2 BILL NO. 06 - FINISHES - Page No. 9.2 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: Internal Finishes (Cont'd) Note: Floor Finishes Note: Supply and apply Heavy duty free solvent epoxy coating including all necessary works complete in accordance with specifications and drawings (Screed measured separately) Code Description Remarks Unit of Measurement Quantity A Ref-FF04 m2 10 Code Description Note: Skirting Note: Supply and apply epoxy skirting including surface preparation, primer coat, final coat and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Ref-Sk02 m 10 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - FINISHES - Page No. 9.3 BILL NO. 06 - FINISHES - Page No. 9.3 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: Internal Finishes (Cont'd) Note: Painting and Decoration Note: Supply and apply paint finish including surface preparation, primer coat, final coat and all necessary works complete in accordance with specifications and drawings (Plaster measured separately) Code Description Remarks Unit of Measurement Quantity A To walls, paint, Ref-WF01 m2 33 B To plastered soffits, paint, Ref-CL03 m2 10 Code Description Note: External Finishes Note: Floor Screed Note: Supply and install cement and sand screed with self levelling compound; including sand filling, surface preparation, and all necessary works; all in according to drawings and specifications Code Description Remarks Unit of Measurement Quantity C To receive Terrazo Tiles m2 9 Code Description Note: Plaster Note: Supply and install cement and sand plaster to block or concrete walls and columns including metal lath and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity D To external block or concrete walls and columns, to receive paint finish m2 85 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - FINISHES - Page No. 9.4 BILL NO. 06 - FINISHES - Page No. 9.4 Code Description Note: DIVISION 09 - FINISHES(CONT'D) Note: External Finishes(Cont'd) Note: Supply and Install terrazo roofing including bedding materials, grouting, jointing and all necessary works complete in accordance with specifications and drawings (Screed measured separately) Code Description Remarks Unit of Measurement Quantity A Terrazo roofing m2 10 Code Description Note: Painting and Decoration Note: Supply and apply paint finish including surface preparation, primer coat, final coat and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B To plastered walls, paint m2 85 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 -MECH INSTALLATION - Page No. 15.1 BILL NO. 06 -MECH INSTALLATION - Page No. 15.1 Code Description Note: DIVISION 15 - MECHANICAL INSTALLATIONS Note: Rainwater, soil, waste, and vent pipework installations complete in accordance with specifications and drawings Note: Pipework Note: Above ground uPVC pipework including fittings, accessories, insect screen, and all necessary works complete in accordance with drawings and specifications Code Description Remarks Unit of Measurement Quantity A 110mm diameter m 4 Code Description Note: Fittings, complete in accordance with drawings and specifications Note: Rain Water Drain Code Description Remarks Unit of Measurement Quantity B Ref. RWO, 110mm diameter No 1 Code Description Note: Fire Fighting System Note: Fire Extinguisher Note: Supply install test and commission fire extinguisher including but not limited to wall fixing frame and hanger and all required components and accessories as per drawings, specifications and civil defense regulations. Code Description Remarks Unit of Measurement Quantity C 5 Kg dry CO2 fire extinguisher No 1 Code Description Note: Building Management System (BMS) Code Description Remarks Unit of Measurement Quantity D Supply, install, test and commissioning of Building management system including points, wires, conduits, and all necessary works complete in accordance with specifications and drawings Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 -MECH INSTALLATION (Cont'd) - Page No. 15.2 BILL NO. 06 -MECH INSTALLATION (Cont'd) - Page No. 15.2 Code Description Note: Sundry / General Items Code Description Remarks Unit of Measurement Quantity A Allow for permits, connection and inspection fees associated with mechanical installations by utility and statutory authorities Item 1 B Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings Item 1 C Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment Item 1 D Allow for setting out the works, marking positions of holes, mortises, chases or the like Item 1 E Allow for testing and commissioning and submission of test certificates Item 1 F Allow for all identification labels, plates, charts and identification of plant, equipment, cable, isolators and the like Item 1 G Allow for preparing schedule of manufacturers recommended tools and spare parts for each piece of equipment Item 1 H Allow for the provision of operating/maintenance manuals Item 1 J Allow for providing shop and coordination drawings Item 1 K Allow for domestic water piping, sterilization and disinfections after commissioning Item 1 L Allow for fire stopping in accordance with the drawings, specification and local authorities requirements Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1 BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS Note: Final Distribution Boards Note: Supply, install, test, commission and maintain Final Distribution boards and terminations including bus bars, breakers, indicators, all interconnecting cables, wires termination and trays from main board, and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Final distribution boards, DB-RMU No 1 Code Description Note: Power Distribution Note: Supply and install the following power fittings including all necessary accessories and connections to wiring and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity B 13A Single switched socket No 1 Code Description Note: Power point Note: Supply and install wiring and conduit in concealed installation including cable trays / trucking, access box with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity C Power points No 1 Code Description Note: Internal Lighting Note: Supply and install lighting including all necessary accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity D Lighting fixture, type W1 No 1 E Ditto, type B1 No 3 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2 BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Power System Installations (Cont'd) Note: Internal Lighting Points Note: Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A Internal Lighting points No 4 Code Description Note: Switches Note: Supply, install, test, commission switches including all necessary accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Two gang, one way lighting switch 20A No 1 Code Description Note: Lighting switch Point Note: Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity C Lighting switch points No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3 BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Emergency and Exit Lighting System Note: Supply, install, test, commission the following emergency and exit light fittings, including ceiling rose, heat resistance, flexible cable, lamps, electronic control gear, suspensions, connections to permanent wiring system in accordance with Specification and drawings Code Description Remarks Unit of Measurement Quantity A Self-contained 1x8w emergency light with built-in battery (3h duration ), surface-mounted, non-maintained No 1 Code Description Note: Emergency lighting points Note: Supply and install wiring and conduit in concealed installation including cable trays / trunking, with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity B Emergency lighting points No 1 Code Description Note: Fire Alarm System Note: Supply, install, test, commission and maintain the complete Analogue addressable fire Alarm & evacuation system including cabling, wiring conduit, cable tray, trunking, termination and power connections and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C Intelligent optical smoke detector and standard base No 1 D Fire alarm junction box No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4 BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Earthing protection system Note: Supply, install, test and commissioning of earthing protection system including earth pits, conductors, bars ,bonds and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Earthing protection Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5 BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Sundry / General Items Code Description Remarks Unit of Measurement Quantity A Allow for permits, connection and inspection fees associated with electrical installations by utility and statutory authorities Item 1 B Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings Item 1 C Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment Item 1 D Allow for setting out the works, marking positions of holes, mortises, chases or the like Item 1 E Allow for testing and commissioning and production of test certificates Item 1 F Allow for all identification labels, plates, charts and identification of plant, equipment, cable, switches and the like Item 1 G Allow for the provision of operating / maintenance manuals Item 1 H Allow for providing shop and coordination drawings Item 1 J Allow for instructing selected employer's personnel on all aspects of the operation of systems and equipment Item 1 K Supply and handover to the client all tools and equipment in accordance with the specification Item 1 L Allow for fire stopping in accordance with the drawings specification and local authorities requirements Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 - SITE WORK - Page No. 2.1 BILL NO. 07 - SITE WORK - Page No. 2.1 Code Description Note: DIVISION 02 - SITE WORKS Note: Site Preparation Code Description Remarks Unit of Measurement Quantity A Site Clearance, including removal of rubbish, debris, vegetation, within the designated work area complete accordance with the specifications and drawings m2 258 Code Description Note: Excavation Note: Excavation from existing level to bottom of foundation levels complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Bulk Excavation m3 1,034 Code Description Note: Backfilling Code Description Remarks Unit of Measurement Quantity C Backfilling, including compaction in layer complete in accordance with specifications and drawings m3 26 Code Description Note: Disposal of Material Arising From Excavations Code Description Remarks Unit of Measurement Quantity D Remove surplus excavated material from site to approved location complete in accordance with specifications and drawings m3 1,008 Code Description Note: Road base Code Description Remarks Unit of Measurement Quantity E Road base, including compaction in layer complete in accordance with specifications and drawings m3 64 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 - SITE WORK (CONT'D) - Page No. 2.2 BILL NO. 07 - SITE WORK (CONT'D) - Page No. 2.2 Code Description Note: DIVISION 02 - SITE WORKS(CONT'D) Note: Anti - Termite Treatment Note: Allow for anti termite treatment under blinding and around building complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Laid horizontally m2 258 B Laid vertically m2 282 Code Description Note: Dewatering Code Description Remarks Unit of Measurement Quantity C Allow for the provision, maintenance and removal on completion of the dewatering system in accordance with specification and drawing Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 - CONCRETE WORK - Page No. 3.1 BILL NO. 07 - CONCRETE WORK - Page No. 3.1 Code Description Note: DIVISION 03 - CONCRETE WORKS Note: IN ACCORDANCE WITH SPECIFICATIONS AND DRAWINGS Note: Sub Structure Note: Plain concrete, C20/25 compressive strength with ordinary Portland cement, GGBS, including shuttering, additives, plasticizers, curing, vibrating, and all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A 100 mm thick Blinding m3 26 Code Description Note: Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating, and all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Raft m3 100 C Wall below grade m3 77 D Slab m3 74 Code Description Note: Steel Reinforcement Note: High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420 N/mm2 for shear design complete in accordance with specification and drawing Code Description Remarks Unit of Measurement Quantity E 12 mm diameter Kg 9,248.87 F 16 mm diameter Kg 18,667.7 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 - CONCRETE WORKS (Cont'd)- Page No. 3.2 BILL NO. 07 - CONCRETE WORKS (Cont'd)- Page No. 3.2 Code Description Note: DIVISION 03 - CONCRETE WORKS Note: IN ACCORDANCE WITH SPECIFICATIONS AND DRAWINGS Note: Sub Structure (Cont`d) Note: Shuttering Note: Temporary shuttering, standard finish including all necessary works complete in accordance with specifications and drawing Code Description Remarks Unit of Measurement Quantity A To sides of raft m2 28 B To sides of wall below grade m2 509 C To sides and soffits of slabs m2 247.77 Code Description Note: Water Stop Note: Allow for PVC water stop as required all in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity D Water Stop m 84 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 - CONCRETE WORKS (Cont'd)- Page No. 3.3 BILL NO. 07 - CONCRETE WORKS (Cont'd)- Page No. 3.3 Code Description Note: SECTION C - CONCRETE WORKS(CONT'D) Note: CONCRETE SUNDRIES Code Description Remarks Unit of Measurement Quantity A Allow for all joints including isolation, control, construction and contraction joints or the like as required all in accordance with the specifications and drawings Item 1 B Allow for equipment base concrete as required all in accordance with the specifications and drawings Item 1 C Allow for structural opening for MEP services and networks throw slabs, beams, columns and foundations all in accordance with the specifications and drawings Item 1 D Allow for all builders work in connection with the whole of MEP works including all manholes, sumps, pits, etc. Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 - METAL WORK - Page No. 5.1 BILL NO. 07 - METAL WORK - Page No. 5.1 Code Description Note: SECTION E - METAL WORKS Note: Non Structural Metal Work Note: Ladders Note: Supply and install tread with triangular support stiffener 4mm thick weld fixed with CHS steel center column including fixing brackets, plates, anchors, protective layer, base plate including fixing, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A steel ladder 2600mm high, 600mm tread No 1 Code Description Note: Access Hatch and Covers Note: Supply and install access opening with double seal heavy duty cover including frames, fixing, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Size 1500x1500mm No 1 C Size 600x600mm No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 - THERMAL & MOISTURE PROTECTION - Page No. 7.1 BILL NO. 07 - THERMAL & MOISTURE PROTECTION - Page No. 7.1 Code Description Note: SECTION G -THERMAL & MOISTURE PROTECTION Note: IN ACCORDANCE WITH SPECIFICATIONS AND DRAWINGS Note: SUB STRUCTURAL WATERPROOF Note: Supply and apply 1000guage polyethylene separation sheet, complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity A Laid horizontally, under raft m2 258 Code Description Note: Supply and apply 1 layer of 4mm THK. each waterproofing membrane torch applied, complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity B Laid horizontally, under raft m2 231 C Laid vertically, side raft m2 35 D Laid vertically, wall below m2 226 E Laid horizontally, Above slab m2 251 Code Description Note: Protection board Note: Supply and install seal tight protection board complete in accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity F Laid vertically & horizontally, 6mm thick m2 254 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 - THERMAL & MOISTURE PROTECTION - Page No. 7.2 BILL NO. 07 - THERMAL & MOISTURE PROTECTION - Page No. 7.2 Code Description Note: SECTION G -THERMAL & MOISTURE PROTECTION (CONT'D) Note: Water tank Finishes Note: Floor Finish Note: Supply and install smooth reinforced concrete with potable water approved cementitious and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity A To floors, Ref FF06 m2 228 Code Description Note: Wall Finishes Note: Supply and install smooth reinforced concrete with potable water approved cementitious and all necessary works complete in accordance with specifications and drawings. Code Description Remarks Unit of Measurement Quantity B To walls, ref. WF03 m2 307 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 -MECH INSTALLATION - Page No. 15.1 BILL NO. 07 -MECH INSTALLATION - Page No. 15.1 Code Description Note: SECTION Q - MECHANICAL INSTALLATIONS Note: Rainwater, soil, waste, and vent pipework installations complete in accordance with specifications and drawings Note: Pipework Note: above ground uPVC pipework including fittings, accessories, insect screen, and all necessary works complete in accordance with drawings and specifications Code Description Remarks Unit of Measurement Quantity A 82mm diameter m 4 B Pressure pipe 50mm m 5 Code Description Note: Under ground uPVC pipework including fittings, accessories, and all necessary works complete in accordance with drawings and specifications Code Description Remarks Unit of Measurement Quantity C 110mm diameter m 1 Code Description Note: Fittings, complete in accordance with drawings and specifications Note: Grating Cover Code Description Remarks Unit of Measurement Quantity D Channel grating 6000x300mm No 1 Code Description Note: Sand Trap Code Description Remarks Unit of Measurement Quantity E Sand trap 600x600x600mm No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.2 BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.2 Code Description Note: SECTION Q - MECHANICAL INSTALLATIONS (CONT'D) Note: Submersible Pump Note: Supply, install test and commission submersible pump set with control panels, valves, check valves, fittings, supports, flexible connections, electrical works, vibration isolation, electronic pressure controller, pressure gauges, protections and all required components and accessories as per drawings and specifications Code Description Remarks Unit of Measurement Quantity A Summersible pump (1 duty/ 1 stand-by), capacity : 50 GPM @ 4m head No 2 Code Description Note: DOMESTIC HOT AND COLD WATER INSTALLATION Note: Cold Water Supply System Note: Supply and install cold water polypropylene pipe works including necessary insulation, fittings, valves and accessories, and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Pump pipe 40mm m 5 C Transfer pipe 40mm m 11 D Incoming line 50mm m 8 Code Description Note: Fittings, complete in accordance with drawings and specifications Note: Isolating Valves Code Description Remarks Unit of Measurement Quantity E 40mm diameter No 6 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.3 BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.3 Code Description Note: SECTION Q - MECHANICAL INSTALLATIONS (CONT'D) Note: Fittings, complete in accordance with drawings and specifications (Cont'd) Note: Copper Ionization Unit Note: Supply, install, test and commission copper ionization unit. Including short pipes, valves, complete with all fittings, supports and all required accessories as per drawings & specifications. Code Description Remarks Unit of Measurement Quantity A Copper ionization unit, flow rate 2.0 L/s No 1 Code Description Note: Pumps Note: Supply, install test and commission transfer water pumps set with control panels, valves, check valves, fittings, supports, flexible connections, electrical works, vibration isolation, electronic pressure controller, pressure gauges, protections and all required components and accessories as per drawings and specifications Code Description Remarks Unit of Measurement Quantity B Water transfer pump set-01 , flow 2.0 L/S, head 3.5 Bar, (1 Duty, 1 Standby). No 2 C Water transfer pump set-02 , flow 2.0 L/S, head 3.5 Bar, (1 Duty, 1 Standby). No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.4 BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.4 Code Description Note: SECTION Q - MECHANICAL INSTALLATIONS (CONT'D) Note: FIRE FIGHTING INSTALLATIONS Note: Supply and install black steel fire fighting water pipe works including drain pipes, fittings, accessories valve and supports and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Fire pipe, 150 mm diameter m 24 B Fire pipe, 200 mm diameter m 3 C Fire pipe header, 200 mm diameter m 3 Code Description Note: Exhaust Pipe Code Description Remarks Unit of Measurement Quantity D Diesel enging exhasut pipe 150mm m 4 Code Description Note: Chimney Exhaust Code Description Remarks Unit of Measurement Quantity E Chimney exhaust terminated and discharge No 1 Code Description Note: Valves and other fittings complete in accordance with specification and drawings Note: Isolating Valve Code Description Remarks Unit of Measurement Quantity F Isoating valve, 200mm No 2 G Isoating valve, 150mm No 1 Code Description Note: Breeching Inlet Code Description Remarks Unit of Measurement Quantity H 150mm dia X 4 Way breeching inlet for tank filling No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.5 BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.5 Code Description Note: SECTION Q - MECHANICAL INSTALLATIONS (CONT'D) Note: Fuel Tank Note: Supply, install, test and commission fuel tank including connections, pipes, access panel, fitting, accessories and valves and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A Fuel tank 300 ltrs with bund wall No 1 Code Description Note: Pumps Note: Supply, install, test and fire fighting pump set with control panels, fittings, supports, flexible connections, electrical works, vibration isolation, electronic pressure controller, pressure gauges, protections and all required components and accessories as per drawings and specifications Code Description Remarks Unit of Measurement Quantity B Fire fighting combined pump set (Electrical, Diesel, Jockey) , flow 1000 GPM, @ 12 bar No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.6 BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.6 Code Description Note: SECTION Q - MECHANICAL INSTALLATIONS (CONT'D) Note: AIR CONDITIONING SYSTEM AND VENTILATION INSTALLATION Note: Chilled Water Pipework Note: DX Unit Note: Supply, install, test and commission DX unit cooling only including but not limited to indoor & outdoor units, vibration isolation, control wiring, flexible connectors, integral control, hanger, supports, filters, sleeves, condensate piping and all required accessories as per drawings and specifications. Code Description Remarks Unit of Measurement Quantity A Ref. 05-SP-01 / CU/02-SP-01, air side 264 L/s No 1 Code Description Note: Fans Note: Supply and install fans including connections, fittings, back draft, and accessories and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity B Ref 05-EXF-01 dome type exhaust fan 300mm dia (weatherproof), flow rate 150 L/s No 1 Code Description Note: Building Management System (BMS) Code Description Remarks Unit of Measurement Quantity C Supply, install, test and commissioning of Building management system including points, wires, conduits, and all necessary works complete in accordance with specifications and drawings Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.7 BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.7 Code Description Note: SECTION Q - MECHANICAL INSTALLATIONS (CONT'D) Note: Sundry / General Items Code Description Remarks Unit of Measurement Quantity A Allow for permits, connection and inspection fees associated with mechanical installations by utility and statutory authorities Item 1 B Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings Item 1 C Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment Item 1 D Allow for setting out the works, marking positions of holes, mortises, chases or the like Item 1 E Allow for testing and commissioning and submission of test certificates Item 1 F Allow for all identification labels, plates, charts and identification of plant, equipment, cable, isolators and the like Item 1 G Allow for preparing schedule of manufacturers recommended tools and spare parts for each piece of equipment Item 1 H Allow for the provision of operating/maintenance manuals Item 1 J Allow for providing shop and coordination drawings Item 1 K Allow for domestic water piping, sterilization and disinfections after commissioning Item 1 L Allow for fire stopping in accordance with the drawings, specification and local authorities requirements Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1 BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1 Code Description Note: SECTION R - ELECTRICAL INSTALLATIONS Note: Power System Note: Final Distribution Boards Note: Supply, install, test, commission and maintain Final Distribution boards and terminations including bus bars, breakers, indicators, all interconnecting cables, wires termination and trays from main board, and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Final distribution boards, DB-PUMP No 1 Code Description Note: Power Distribution Note: Supply and install the following power fittings including all necessary accessories and connections to wiring and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity B 13A Single switched socket W/P No 1 C 13A Switched spur outlet No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2 BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2 Code Description Note: SECTION R - ELECTRICAL INSTALLATIONS(CONT'D) Note: Power System (Cont`d) Note: Power point Note: Supply and install wiring and conduit in concealed installation including cable trays / trucking, access box with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A Power points No 2 Code Description Note: Isolating Switch Note: Supply and install isolating switch including all interconnecting and terminations and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity B Isolator single phase 32A IP65 No 2 C Isolator three phase 32A IP65 No 2 D Isolator single phase 40A IP65 No 1 E Isolator three phase 500A IP65 No 1 Code Description Note: Internal Lighting Note: Supply and install lighting including all necessary accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity F Lighting fixture, type L1 No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3 BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3 Code Description Note: SECTION R - ELECTRICAL INSTALLATIONS(CONT'D) Note: Lighting System Note: Internal Lighting Points Note: Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A Internal Lighting points No 2 Code Description Note: Switches Note: Supply, install, test, commission switches including all necessary accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B One gang, one way lighting switch 20A No 1 Code Description Note: Lighting switch Point Note: Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity Code / Note Title Lighting switch points No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4 BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4 Code Description Note: SECTION R - ELECTRICAL INSTALLATIONS(CONT'D) Note: Fire Alarm System Note: Supply, install, test, commission and maintain the complete Analogue addressable fire Alarm & evacuation system including cabling, wiring conduit, cable tray, trunking, termination and power connections and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Intelligent optical smoke detector and standard base No 1 B Fire alarm sounder or horn W/P No 1 C Fire alarm junction box No 1 D Dual input module No 1 E Monitoring module No 1 Code Description Note: Earthing protection system Note: Supply, install, test and commissioning of earthing protection system including earth pits, conductors, bars ,bonds and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity F Earthing protection Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5 BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Sundry / General Items Code Description Remarks Unit of Measurement Quantity A Allow for permits, fees, inspection associated with electrical installations by utility and statutory authorities Item 1 B Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment Item 1 C Allow for setting out the works, marking positions of holes, mortises, chases or the like Item 1 D Allow for testing and commissioning and production of test certificates Item 1 E Allow for all identification labels, plates, charts and identification of plant, equipment, cable, switches and the like Item 1 F Allow for the provision of operating / maintenance manuals Item 1 G Allow for providing shop and coordination drawings Item 1 H Allow for instructing selected employer's personnel on all aspects of the operation of systems and equipment Item 1 J Supply and handover to the client all tools and equipment in accordance with the specification Item 1 K Allow for fire stopping in accordance with the drawings specification and local authorities requirements Item 1 L Allow for all builders work in connection with the whole of the electrical installation including all manholes, sumps, pits etc. Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - SITE WORK - Page No. 2.1 BILL NO. 08 - SITE WORK - Page No. 2.1 Code Description Note: DIVISION 02 - SITE WORKS Note: Site Preparation Code Description Remarks Unit of Measurement Quantity A Site Clearance, including removal of rubbish, debris, vegetation within the designated work area and all necessary works complete accordance with the specifications and drawings m2 24,415 Code Description Note: Excavation Note: Excavation from existing level to bottom of foundation levels including all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Bulk excavation m3 5,876 Code Description Note: Disposal of Material Arising From Excavations Code Description Remarks Unit of Measurement Quantity C Remove surplus excavated material from site to approved location including and all necessary works complete in accordance with specifications and drawings m3 5,876 Code Description Note: Demolition Note: Allow for carefully demolition of existing construction elements including, removing the rubbish from site, making good complete as shown on drawings and as specified. Code Description Remarks Unit of Measurement Quantity D To boundary wall m 22 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.2 BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.2 Code Description Note: DIVISION 02 - SITE WORKS (CONT'D) Note: Site Furniture And Equipment Note: Supply and installation of Site Furniture and equipment, including excavation, filling, reinforcement, foundation, concrete, finishes, fixing, fittings, and all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Benches, ref. F-B-03A-1, F-B-03A-2, F-B-03B and F-B-03C No 4 B Trach bin, Ref. F-T-01 No 4 C Inclusive seat, Ref. SW990207 No 1 D Play panel 2 music, Ref. NRO613 No 1 E Universal carousel, Ref. PCM157 No 1 F Kids table, Ref. NRO212 No 1 G Flex wheel, Ref. FSW226 No 2 H Surface challenge 5, Ref. FSW225 No 2 J COM BI 5, Ref. FSW105 No 2 K Balance board, Ref. FSW231 No 2 L Inclusive double chest press, Ref. FSW244 No 2 M ARM bike, Ref. FSW240 No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.3 BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.3 Code Description Note: DIVISION 02 - SITE WORKS (CONT'D) Note: Shade Note: Supply and installation shade structure, including civil works, reinforcement, foundation, concrete, high density PVC fabric shade, hot dipped galvanized support frame & column and all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Shade parking m2 2,161 Code Description Note: Potable Security Room Note: Supply and install potable security room including finishes, power connection, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Size 2400 x 1800 mm No 1 C Size 2450 x 1850 mm No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.4 BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.4 Code Description Note: DIVISION 02 - SITE WORKS (CONT'D) Note: Boundary Wall Note: Boundary wall including excavation, backfilling, concrete work, reinforcement, formwork, waterproofing, finishes, metal gate, and all necessary work complete accordance with the specifications and drawings Code Description Remarks Unit of Measurement Quantity A To boundary wall, 3680mm high m 5 B To boundary wall, 4000mm high m 174 C To boundary wall, 4980mm high m 39 D To boundary wall, 5410mm high m 8 E To boundary wall, 5640mm high m 12 F To boundary wall, 5800mm high m 10 G To boundary wall, 5840mm high m 16 H To boundary wall, 6570mm high m 16 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.5 BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.5 Code Description Note: DIVISION 02 - SITE WORKS (CONT'D) Note: Irrigation System Note: Supply and installation of Irrigation line piping including fittings installation accessories, with all related civil works such as excavation, levelling, compaction, laying and backfilling all in accordance with Drawings and Specifications. Note: PVC Filling Line Code Description Remarks Unit of Measurement Quantity A Filling line 50mm diameter m 3 Code Description Note: Upvc Lateral Line Pipe CL10 Code Description Remarks Unit of Measurement Quantity B 32mm diameter m 1,819 C 50mm diameter m 596 D 63mm diameter m 177 E 90mm diameter m 55 Code Description Note: Allow Lateral Line Duct Code Description Remarks Unit of Measurement Quantity F To pipe 32mm diameter m 16 G To pipe 50mm diameter m 38 Code Description Note: Irrigation Cable Decoder Note: Supply and installation of cable decoder with necessary conduit, fittings, fixings and accessories all in accordance with drawings and specifications. Code Description Remarks Unit of Measurement Quantity H Cable decoder Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.6 BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.6 Code Description Note: DIVISION 02 - SITE WORKS (CONT'D) Note: Irrigation System(Cont'd) Note: Valves and other fittings complete in accordance with specification and drawings Note: Isolating Valves Code Description Remarks Unit of Measurement Quantity A 50mm diameter No 1 Code Description Note: Valves and Accessories Note: Supply and installation of valves with necessary conduit, wires, fittings, fixings and accessories all in accordance with drawings and specifications. Code Description Remarks Unit of Measurement Quantity B Air valve 50 mm diameter No 83 C Air valve 63 mm diameter No 2 D Gate valve 90 mm diameter No 1 E Pull box No 57 F Drip riser point No 1,009 G Float Valve 50mm diameter No 1 H Solenoid valve SV01 1.5'' No 1 J Solenoid valve SV02 1.5'' No 1 K Solenoid valve SV03 1.5'' No 1 L Solenoid valve SV04 1.5'' No 1 M Solenoid valve SV05 1.5'' No 1 N Solenoid valve SV06 1.5'' No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.7 BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.7 Code Description Note: DIVISION 02 - SITE WORKS (CONT'D) Note: Irrigation System(Cont'd) Note: Valves and Accessories(Cont'd) Note: Supply and installation of valves with necessary conduit, wires, fittings, fixings and accessories all in accordance with drawings and specifications.(Cont'd) Code Description Remarks Unit of Measurement Quantity A Solenoid valve SV07 1.5'' No 1 B Solenoid valve SV08 1.5'' No 1 C Solenoid valve SV09 1.5'' No 2 D Solenoid valve SV10 1.5'' No 1 E Solenoid valve SV11 1.5'' No 1 F Solenoid valve SV12 1.5'' No 1 G Solenoid valve SV13 1.5'' No 1 H Solenoid valve SV14 1.5'' No 1 J Solenoid valve SV15 1.5'' No 1 K Solenoid valve SV16 1.5'' No 1 L Solenoid valve SV17 1.5'' No 2 M Solenoid valve SV18 1.5'' No 1 N Solenoid valve SV19 1.5'' No 1 P Solenoid valve SV20 1.5'' No 1 Q Solenoid valve SV21 1.5'' No 1 R Solenoid valve SV22 1.5'' No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.8 BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.8 Code Description Note: DIVISION 02 - SITE WORKS (CONT'D) Note: Irrigation System(Cont'd) Note: Valves and Accessories(Cont'd) Note: Supply and installation of valves with necessary conduit, wires, fittings, fixings and accessories all in accordance with drawings and specifications.(Cont'd) Code Description Remarks Unit of Measurement Quantity A Solenoid valve SV23 1.5'' No 1 B Solenoid valve SV24 1.5'' No 1 C Solenoid valve SV25 1.5'' No 1 D Solenoid valve SV26 1.5'' No 1 E Solenoid valve SV27 1.5'' No 1 F Solenoid valve SV28 1.5'' No 1 G Solenoid valve SV29 1.5'' No 1 H Solenoid valve SV30 1.5'' No 1 J Solenoid valve SV31 1.5'' No 1 K Solenoid valve SV32 1.5'' No 1 L Solenoid valve SV33 1.5'' No 1 M Solenoid valve SV34 1.5'' No 1 N Solenoid valve SV35 1.5'' No 1 P Solenoid valve SV36 1.5'' No 1 Q Solenoid valve SV37 1.5'' No 1 R Solenoid valve SV38 1.5'' No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.9 BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.9 Code Description Note: DIVISION 02 - SITE WORKS (CONT'D) Note: Irrigation System(Cont'd) Note: Valves and Accessories(Cont'd) Note: Supply and installation of valves with necessary conduit, wires, fittings, fixings and accessories all in accordance with drawings and specifications.(Cont'd) Code Description Remarks Unit of Measurement Quantity A Solenoid valve SV39 1.5'' No 1 B Solenoid valve SV40 1.5'' No 1 C Solenoid valve SV41 1.5'' No 1 D Solenoid valve SV42 1.5'' No 1 E Solenoid valve SV43 1.5'' No 1 F Solenoid valve SV44 1.5'' No 1 G Solenoid valve SV45 1.5'' No 1 H Solenoid valve SV46 1.5'' No 1 J Solenoid valve SV47 1.5'' No 1 K Solenoid valve SV48 1.5'' No 1 L Solenoid valve SV49 1.5'' No 1 M Solenoid valve SV50 1.5'' No 1 N Solenoid valve SV51 1.5'' No 1 P Solenoid valve SV52 1.5'' No 1 Q Solenoid valve SV53 1.5'' No 1 R Solenoid valve SV54 1.5'' No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.10 BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.10 Code Description Note: DIVISION 02 - SITE WORKS (CONT'D) Note: Irrigation System(Cont'd) Note: Valves and Accessories(Cont'd) Note: Supply and installation of valves with necessary conduit, wires, fittings, fixings and accessories all in accordance with drawings and specifications.(Cont'd) Code Description Remarks Unit of Measurement Quantity A Solenoid valve SV55 1.5'' No 1 B Solenoid valve SV56 1.5'' No 1 C Solenoid valve SV57 1.5'' No 1 Code Description Note: Water Meter Code Description Remarks Unit of Measurement Quantity D Water monitoring meter for irrigation within valve chamber No 1 Code Description Note: Pumps Note: Supply, install test and commission pumps complete with control panels, valves, headers, check valves, fittings, supports, flexible connections, electrical works, vibration isolation, electronic pressure controller, pressure gauges, pressure vessel, protections and all required components and accessories as per drawings and specifications Code Description Remarks Unit of Measurement Quantity E Irrigation pump, (1 duty), flow = ** l/s head** bar No 1 F Irrigation pump, (1 standby), flow = ** l/s head** bar No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.11 BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.11 Code Description Note: DIVISION 02 - SITE WORKS (CONT'D) Note: Hard Landscape Note: External Floor Finishes Note: Supply and install floor finish including all underlayment's, sand, subgrade, pointing, jointing complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A 80mm thick interlock to entrance road m2 1,100 B 60mm thick interlock to entrance road m2 52 C Precast concrete paving, ref. PA-01, size 200x400x60mm, greige color m2 2,824 D Precast concrete paving, ref. PA-02, size 200x400x60mm, dark gray color m2 343.6 E Precast concrete paving, ref. PA-03, size 200x400x60mm, light gray color m2 725 F Granite paving, ref. PA-04, size 100x100x60mm, black color m2 1,035 Code Description Note: Rubber flooring, including all underlayment's and all necessary work complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity G Rubber, ref. PA-05, 20mm thick, blue color m2 58 H Rubber, ref. PA-06, 20mm thick, yellow color m2 188 J Rubber, ref. PA-08, 20mm thick, green color m2 60 K Rubber, ref. PA-09, 20mm thick, red color m2 82 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.12 BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.12 Code Description Note: DIVISION 02 - SITE WORKS (CONT'D) Note: Hard Landscape (Cont'd) Note: External Floor Finishes (Cont'd) Note: Reflexology garden, including all underlayment's and all necessary work complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Reflexology garden, ref. PA-10, light gray color m2 72 Code Description Note: Sand, including all underlayment's and all necessary work complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity B Sand, ref. PA-11, light gray color m2 106 Code Description Note: Supply and install asphalt road including compaction and all necessary work complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C 60mm thick wearing course asphaltic concrete m2 6,033 D Prime coat m2 6,555 E 200mm thick base course aggregate m2 6,555 F 150mm thick sub base granular m2 6,555 Code Description Note: Supply and install Kerb stone including concrete hunching, foundation, cement mortar, sand fill, waterproofing and painting complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity G Upstand kerb stone 420x200mm m 4,090 H Flush kerb stone m 377 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.13 BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.13 Code Description Note: DIVISION 02 - SITE WORKS (CONT'D) Note: Landscape (Cont'd) Note: Soft Landscape Note: Supply and planting of trees, shrubs and ground cover as detail including excavation, filling, planting soil, irrigation water and pesticides, gravel, waterproofing any required complete in accordance with specifications and drawings Note: Tree Code Description Remarks Unit of Measurement Quantity A Palm tree, ref. P-T-01 No 76 B Cassia nodosa, ref. P-T-02 No 6 C Pongamia blabra, ref. P-T-03 No 12 D Plumeria rubra, ref. P-T-04 No 25 E Lagerstroem ia indica, ref. P-T-05 No 13 F Bauhinia variegata, ref. P-T-06 No 8 G Albizia julibrissen, ref. P-T-07 No 4 Code Description Note: Shrubs And Ground Cover Grass Code Description Remarks Unit of Measurement Quantity H Bougainvillea glabra (pink), ref. P-S-01 m2 72 J Jatropha integerrima (pink), ref. P-S-03 m2 308 K Ruellia ciliosa (pink), ref. P-S-04 m2 808 L Ipomoea, ref. P-S-05 m2 315 M Ruellia brittoniana (pink), ref. P-S-06 m2 21 N Paspalum vaginatum, ref. P-S-07 m2 6,990 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - ACCESSORIES - Page No. 10.1 BILL NO. 08 - ACCESSORIES - Page No. 10.1 Code Description Note: DIVISION 10 - ACCESSORIES Note: Marking Paint Note: Supply and apply marking paint including and all necessary works complete in accordance with specification , drawings Code Description Remarks Unit of Measurement Quantity A Marking paint line between parking m 1,307 B Marking paint stop line m 173 C Dashed center line m 651 D Right arrow No. 6 E Left arrow No. 3 F Straight arrow No. 30 G Straight with left arrow No. 3 H Straight with right arrow No. 4 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - ACCESSORIES (Cont'd)- Page No. 10.2 BILL NO. 08 - ACCESSORIES (Cont'd)- Page No. 10.2 Code Description Note: DIVISION 10 - ACCESSORIES(CONT'D) Note: Marking Paint Note: Supply and apply marking paint including and all necessary works complete in accordance with specification , drawings Code Description Remarks Unit of Measurement Quantity A Left with right arrow No. 2 B Handicap sign No. 7 C Charger sign m2 4 D Pedestrian crossing 6200x4600mm No. 1 E Hatch paint Handicap area m2 46 F Parking numbers No. 149 Code Description Note: Wheel Stopper Note: Supply and install precast concrete wheel stopper including painting, all fittings, accessories and connections and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity G Size 2000x150x120mm No 148 Code Description Note: Temporary Fence Note: Temporary corrugated fencing sheet during construction only with one secure pedestrian gate(1000mm) including steel support, steel post, precast concrete base, all fixing, fittings, accessories and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity H Temporary fence, 2000mm high m 406 Code Description Note: Signage Code Description Remarks Unit of Measurement Quantity J Supply and install external signage including all fittings, fixings, support, accessories and civil works all in accordance with specifications and drawings Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 -MECH INSTALLATION - Page No. 15.1 BILL NO. 08 -MECH INSTALLATION - Page No. 15.1 Code Description Note: DIVISION 15 - MECHANICAL WORKS Note: MECHANICAL SITE WORKS Note: Drainage System Note: Supply, install, test and commission uPVC pipes complete with fittings, rubber gasket and accessories, warning tape, excavation, backfilling, thrust blocks, and all other accessories as per drawings and specification Code Description Remarks Unit of Measurement Quantity A 110mm diameter m 133 B 200mm diameter m 466 C Suction line to holding tank, 100mm diameter m 31 Code Description Note: Manholes Note: Supply, and install, manhole complete with cover, rubber gasket and accessories, civil works, excavation, backfilling, ladders, and all other accessories as per drawings and specification Code Description Remarks Unit of Measurement Quantity D B2-MH-01, size 600x600x450mm, with medium duty cover and vent and vent No 1 E B2-MH-02, size 600x600x560mm, with medium duty cover No 1 F B2-MH-03, size 600x600x650mm, with medium duty cover No 1 G B2-MH-04, size 600x600x830mm, with medium duty cover No 1 H B2-MH-05, size 600x600x950mm, with medium duty cover No 1 J B2-MH-06, size 800x800x1030mm, with medium duty cover No 1 K B2-MH-07, size 600x600x1150mm, with medium duty cover No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.2 BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.2 Code Description Note: DIVISION 15 - MECHANICAL WORKS (CONT'D) Note: Manholes (Cont'd) Note: Supply, and install, manhole complete with cover, rubber gasket and accessories, civil works , excavation, backfilling, ladders, and all other accessories as per drawings and specification (Cont'd) Code Description Remarks Unit of Measurement Quantity A B2-MH-08, size 600x600x1300mm, with medium duty cover No 1 B B2-MH-09, size 600x600x450mm, with medium duty cover and vent No 1 C B2-MH-10, size 600x600x530mm, with medium duty cover No 1 D B2-MH-11, size 600x600x620mm, with medium duty cover No 1 E B2-MH-12, size 600x600x690mm, with meduim duty cover No 1 F B2-MH-13, size 600x600x780mm, with medium duty cover No 1 G B2-MH-14, size 600x600x1360mm, with medium duty cover No 1 H B2-MH-15, size 1000x1000x1360, with medium duty cover No 1 J B1-MH-01, size 600x600x450mm, with medium duty cover and vent No 1 K B1-MH-02, size 600x600x580mm, with medium duty cover No 1 L B1-MH-03, size 600x600x670mm, with medium duty cover No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.3 BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.3 Code Description Note: DIVISION 15 - MECHANICAL WORKS (CONT'D) Note: Manholes (Cont'd) Note: Supply, and install, manhole complete with cover, rubber gasket and accessories, civil works , excavation, backfilling, ladders, and all other accessories as per drawings and specification(Cont'd) Code Description Remarks Unit of Measurement Quantity A B1-MH-04, size 600x600x850mm, with medium duty cover No 1 B B1-MH-05, size 600x600x950mm, with medium duty cover No 1 C B1-MH-06, size 800x800x1090mm, with medium duty cover No 1 D B1-MH-07, size 600x600x450mm, with medium duty cover and vent No 1 E B1-MH-08, size 600x600x510mm, with medium duty cover No 1 F B1-MH-09, size 600x600x580mm, with medium duty cover No 1 G B1-MH-10, size 600x600x670mm, with medium duty cover No 1 H B1-MH-11, size 600x600x740mm, with medium duty cover No 1 J B1-MH-12, size 600x600x770mm, with medium duty cover No 1 K B1-MH-13, size 600x600x890mm, with medium duty cover No 1 L B1-MH-14, size 800x800x1000mm, with medium duty cover No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.4 BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.4 Code Description Note: DIVISION 15 - MECHANICAL WORKS (CONT'D) Note: Manholes (Cont'd) Note: Supply, and install, manhole complete with cover, rubber gasket and accessories, civil works , excavation, backfilling, ladders, and all other accessories as per drawings and specification (Cont'd) Code Description Remarks Unit of Measurement Quantity A B1-MH-15, size 800x800x1200mm, with medium duty cover and vent No 1 B B1-MH-16, size 600x600x450mm, with medium duty cover No 1 C B1-MH-17, size 600x600x620mm, with medium duty cover No 1 D B1-MH-18, size 600x600x740mm, with medium duty cover No 1 E B1-MH-19, size 600x600x910mm, with medium duty cover No 1 F B1-MH-20, size 800x800x1070mm, with medium duty cover No 1 G B1-MH-21, size 1000x1000x1270mm, with medium duty cover with vent No 1 H B2-MH-15A, size 600x600x450mm, with medium duty cover and vent No 1 J B2-MH-15B, size 600x600x570mm, with medium duty cover No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.5 BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.5 Code Description Note: DIVISION 15 - MECHANICAL WORKS (CONT'D) Note: Manholes (Cont'd) Note: Supply, and install, manhole complete with cover, rubber gasket and accessories, civil works , excavation, backfilling, ladders, and all other accessories as per drawings and specification(Cont'd) Code Description Remarks Unit of Measurement Quantity A B2-MH-15C, size 600x600x690mm, with medium duty cover No 1 B B2-MH-15D, size 600x600x850mm, with medium duty cover No 1 C PRM, size 600x600x450mm, with medium duty cover and vent No 1 Code Description Note: Gully Trap Note: Supply, and install, gully trap complete with cover, and all other accessories as per drawings and specification Code Description Remarks Unit of Measurement Quantity D Gully trap 300x300mm No 20 Code Description Note: Holding Tank Note: Supply, and install, holdign tank including civil work, complete with connections, pipes, fitting, accessories and valves and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity E Holding tank, dimension 7.50 x 2.2 x 3.0 m No 2 Code Description Note: Breaching Inlet Code Description Remarks Unit of Measurement Quantity F 4 way breaching inlet to holding tank No 2 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.6 BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.6 Code Description Note: DIVISION 15 - MECHANICAL WORKS (CONT'D) Note: Domestic Hot and Cold Water Installation Note: Cold Water Supply System Note: Supply and install cold water PVC pipe works including necessary, fittings, valves, excavation, backfill, accessories, and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Transfer line 40mm diameter m 283 B Filling line 50mm diameter m 278 C Ref. BCWS 20mm diameter m 125 Code Description Note: Duct Crossing Code Description Remarks Unit of Measurement Quantity D Water supply pipe duct crossing 300x300mm m 399 Code Description Note: Valve Chamber Note: Supply and install valve chamber including and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity E Valve chamber No 3 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.7 BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.7 Code Description Note: DIVISION 15 - MECHANICAL WORKS (CONT'D) Note: Fire Fighting System Note: Supply and install under-ground HDPE fire fighting water pipe works including drain pipe, fitting, accessories valve, excavation and backfilling, and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A Fire pipe 150mm diameter m 493 Code Description Note: Duct Crossing Code Description Remarks Unit of Measurement Quantity B Duct crossing to pipe 150mm m 144 Code Description Note: Equipment and Fittings as Specified Note: Isolating Valve Code Description Remarks Unit of Measurement Quantity C Isolation valve in chamber 150mm No 6 Code Description Note: Fire Hydrant Code Description Remarks Unit of Measurement Quantity D Private fire hydrant No 6 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.8 BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.8 Code Description Note: SECTION Q - MECHANICAL INSTALLATIONS (CONT'D) Note: Sundry / General Items Code Description Remarks Unit of Measurement Quantity A Allow for permits, connection and inspection fees associated with mechanical installations by utility and statutory authorities Item 1 B Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings Item 1 C Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment Item 1 D Allow for setting out the works, marking positions of holes, mortises, chases or the like Item 1 E Allow for testing and commissioning and submission of test certificates Item 1 F Allow for all identification labels, plates, charts and identification of plant, equipment, cable, isolators and the like Item 1 G Allow for preparing schedule of manufacturers recommended tools and spare parts for each piece of equipment Item 1 H Allow for the provision of operating/maintenance manuals Item 1 J Allow for providing shop and coordination drawings Item 1 K Allow for domestic water piping, sterilization and disinfections after commissioning Item 1 L Allow for fire stopping in accordance with the drawings, specification and local authorities requirements Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1 BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1 Code Description Note: DIVISION 16 - ELECTRICAL WORKS Note: ELECTRICAL SITE WORKS Note: Power System Note: Feeder Pillar Code Description Remarks Unit of Measurement Quantity A Feeder pillar, ref FP-ED1 IP68 No 1 B Feeder pillar, ref FP-POD1 IP68 No 1 C Feeder pillar, ref FP-ED2 IP68 No 1 D Feeder pillar, ref FP-POD2 IP68 No 1 E Feeder pillar, ref FP-ED3 IP68 No 1 F Feeder pillar, ref FP-POD3 IP68 No 1 Code Description Note: Electrical Manhole Note: Electrical manhole with heavy duty cover, complete including, all civil works and accessories, and all other work as per drawings and specification Code Description Remarks Unit of Measurement Quantity G Electrical manhole, size 800x800x800mm No 28 Code Description Note: Underground Duct Note: Supply and install of uPVC duct with fittings and accessories, including excavation, backfilling,, concrete encasement and all other work as per drawings and specification Code Description Remarks Unit of Measurement Quantity H uPVC Duct, 50mm dia m 400 J uPVC Duct, 100mm dia m 1,175 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2 BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2 Code Description Note: DIVISION 16 - ELECTRICAL WORKS (CONT'D) Note: ELECTRICAL SITE WORKS (CONT'D) Note: Cables Note: Low Voltage armoured cables including ducts, glands, connections, conduits, excavation, backfilling, manholes, warning tap, termination, trays and all necessary works complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity A 4C.6mm2 fire rated XLPE/SWA/PVC +1C.6 mm2 fire rated PVC/ECC/CU m 212 B 2C.10mm2 XLPE/SWA/PVC +1C.10 mm2 PVC/ECC/CU m 55 C 4C.10mm2 XLPE/SWA/PVC +1C.10mm2 PVC/ECC/CU m 583 D 2C.16mm2 XLPE/SWA/CU/PVC +1C.16mm2 CPC m 269 E 2C.16mm2 XLPE/SWA/PVC +1C.16mm2 PVC/ECC/CU m 88 F 4C.16mm2 XLPE/SWA/PVC +1C.16mm2 PVC/ECC/CU m 273 G 4C.25mm2 XLPE/SWA/PVC +1C.16mm2 PVC/ECC/CU m 210 H 4C.95mm2 XLPE/SWA/PVC +1C.50mm2 PVC/ECC/CU m 216 J 2x 4C x 185mm2 XLPE/SWA/CU/PVC+ 2X1C x 95 mm2 CPC m 424 K 2x 4C x 240 mm2 XLPE/SWA/CU/PVC+ 2X1C x 120 mm2 CPC m 422 L 2x 4C x 150 mm2 fire rated XLPE/SWA/CU/PVC+ 2X1C x 70 mm2 fire rated CPC m 55 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3 BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3 Code Description Note: DIVISION 16 - ELECTRICAL WORKS (CONT'D) Note: ELECTRICAL SITE WORKS (CONT'D) Note: Power Distribution Note: Supply and install the following power fittings including all necessary accessories and connections to wiring and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A 13A Single switched socket W/P No 18 Code Description Note: Power point Note: Supply and install wiring and conduit in concealed installation including duct, access box with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity B Power points No 18 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4 BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4 Code Description Note: DIVISION 16 - ELECTRICAL WORKS (CONT'D) Note: ELECTRICAL SITE WORKS (CONT'D) Note: Isolating Switch Note: Supply and install isolating switch including all interconnecting and terminations and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A Isolator single phase 32A IP65 No 5 B Isolator single phase 40A IP68 No 2 C Isolator three phase 40A IP65 No 2 Code Description Note: External Lighting Note: Supply and installation of external lighting including bases, conduit, wire, termination, with all necessary works, complete in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity D External lighting fixture, type L-C-01 No 79 E Ditto, type L-C-03 No 75 F Ditto, type L-C-04 No 30 G Ditto, type L-C-05 No 10 H Ditto, type L-C-06 No 3 J Ditto, type L-C-07 No 64 K Ditto, type L-C-08 No 67 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5 BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5 Code Description Note: DIVISION 16 - ELECTRICAL WORKS (CONT'D) Note: ELECTRICAL SITE WORKS (CONT'D) Note: External Lighting Points Note: Supply and install wiring and conduit in concealed installation including conduit, excavation, backfill, with all accessories, and all necessary works complete in accordance with specification and drawings Code Description Remarks Unit of Measurement Quantity A External lighting points No 328 Code Description Note: Fire Alarm System Note: Fire Alarm Manholes Note: Fire alarm manhole with cover, complete including, all civil works and accessories, and all other work as per drawings and specification Code Description Remarks Unit of Measurement Quantity B Manholes, size 300x300x300mm No 16 Code Description Note: Underground Duct Note: Supply and install of uPVC duct with fittings and accessories, including excavation, backfilling,, concrete encasement and all other work as per drawings and specification Code Description Remarks Unit of Measurement Quantity C uPVC Duct, 100mm dia m 309 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6 BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6 Code Description Note: DIVISION 16 - ELECTRICAL WORKS (CONT'D) Note: ELECTRICAL SITE WORKS (CONT'D) Note: Telecom System Note: Telecom Manholes Note: Telecom manhole with cover, complete including, all civil works and accessories, and all other work as per drawings and specification Code Description Remarks Unit of Measurement Quantity A Manholes, size 600x600x800mm No 22 Code Description Note: Underground Duct Note: Supply and install of uPVC duct with fittings and accessories, including excavation, backfilling,, concrete encasement and all other work as per drawings and specification Code Description Remarks Unit of Measurement Quantity B uPVC Duct, 50mm dia m 682 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.7 BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.7 Code Description Note: DIVISION 16 - ELECTRICAL WORKS (CONT'D) Note: ELECTRICAL SITE WORKS (CONT'D) Note: Low Current Manholes Note: Low current manhole with cover, complete including, all civil works and accessories, and all other work as per drawings and specification Code Description Remarks Unit of Measurement Quantity A Manholes, size 300x300x300mm No 23 Code Description Note: Underground Duct Note: Supply and install of uPVC duct with fittings and accessories, including excavation, backfilling,, concrete encasement and all other work as per drawings and specification Code Description Remarks Unit of Measurement Quantity B uPVC Duct, 50mm dia m 473 Code Description Note: CCTV System Note: Supply install, test and commission complete CCTV system including rack, monitors, controllers , cabling, wiring, conduit and power connections, and all necessary works complete all in accordance with specifications and drawings Code Description Remarks Unit of Measurement Quantity C ANPR cameras pole mounted No 6 D IES-Industrial ethernet switch No 3 E Bullet cameras pole mounted No 33 F Temporary bullet cameras pole mounted No 8 G Temporary IES-Industrial ethernet switch No 2 H 12U Temporary CCTV rack No 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.8 BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.8 Code Description Note: DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D) Note: Sundry / General Items Code Description Remarks Unit of Measurement Quantity A Allow for permits, connection and inspection fees associated with electrical installations by utility and statutory authorities Item 1 B Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings Item 1 C Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment Item 1 D Allow for setting out the works, marking positions of holes, mortises, chases or the like Item 1 E Allow for testing and commissioning and production of test certificates Item 1 F Allow for all identification labels, plates, charts and identification of plant, equipment, cable, switches and the like Item 1 G Allow for the provision of operating / maintenance manuals Item 1 H Allow for providing shop and coordination drawings Item 1 J Allow for instructing selected employer's personnel on all aspects of the operation of systems and equipment Item 1 K Supply and handover to the client all tools and equipment in accordance with the specification Item 1 L Allow for fire stopping in accordance with the drawings specification and local authorities requirements Item 1 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 09 - PROVISIONAL SUM - Page No. PS.1 BILL No. 09 - PROVISIONAL SUM - Page No. PS.1 Code Description Note: PROVISIONAL SUM Note: Authority Fees and Connection Charges Code Description Remarks Unit of Measurement Quantity A Allow for amount of AED 650,000.00 (Six Hundred Fifty Thousand Dirham) for authority fees and connections including for supply and install of transformer and all necessary works, complete as per Engineer instruction and provided drawings & specifications. sum 1 Code Description Note: Dubai Municipality: Costs of connecting to the sewage system Note: 'Dubai Electricity and Water Authority: Costs of connecting to electricity and water Note: 'Security Industry Regulatory Agency: Costs of system adoption, technical inspection and system connection with Dubai Police Note: 'Civil Defense Authority: Costs of accreditation and system connection with 24x7 smart civil defense monitoring system Note: 'Etisalat/ Du: No specific costs as the service is connected to the main telephone room (Bulk Service), and the operator provides its own exchange system and internal distributions. The beneficiary party contracts directly with Etisalat for the required package and service provision. Note: 'Roads and Transport Authority: According to the requirements of the beneficiary party and recommendations of stakeholders/ experts TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.1 BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.1 Code Description Note: DAY WORK Note: SCHEDULE OF RATES FOR DAY WORKS Note: Labor Code Description Remarks Unit of Measurement Quantity A Non-supervisory working foremen Hr 100 B Laborers/helpers Hr 100 C Scaffolders Hr 100 D Steel fixers Hr 100 E Drainage layers Hr 100 F Carpenters and Joiners Hr 100 G Plasterers Hr 100 H Block layers, masons and tile fixers Hr 100 J Plumbers Hr 100 K Painters Hr 100 L Plant and machinery operators and drivers Hr 100 M Electricians/A.C. mechanics Hr 100 N Welders Hr 100 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.2 BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.2 Code Description Note: SCHEDULE OF RATES FOR DAYWORKS (Cont'd) Note: Materials Code Description Remarks Unit of Measurement Quantity A Building sand m3 30 B Aggregate (to pass 29 mm) m3 25 C Grade 40 ready-mix concrete m3 20 D Portland cement - grey Tn 10 E Sulphate resisting cement Tn 10 F Mild steel reinforcement bars (all sizes) Tn 10 G High tensile steel reinforcement bars (all sizes) Tn 10 H Epoxy coating to steel reinforcement (all sizes) Tn 1 J Use and waste only on timber in sawn formwork m2 50 K Use and waste only on timber in wrote formwork m2 50 L Solid concrete blocks 100mm thick m2 50 M Ditto, 200mm thick m2 50 N Hollow concrete blocks 100mm thick m2 50 P Ditto, 150mm thick m2 50 Q Ditto, 200mm thick m2 50 R Softwood for carpentry (any size) m3 50 S Hardwood for joinery (any size) m3 50 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.3 BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.3 Code Description Note: SCHEDULE OF RATES FOR DAYWORKS (Cont'd) Note: Materials (Cont'd) Code Description Remarks Unit of Measurement Quantity A 12mm plywood m2 50 B 20mm plywood m2 50 C 12mm blackboard m2 50 D Epoxy paint liter 20 E Vinyl acrylic emulsion paint liter 20 F Oil paint liter 20 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.4 BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.4 Code Description Note: SCHEDULE OF RATES FOR DAYWORKS (Cont'd) Note: Plant Code Description Remarks Unit of Measurement Quantity A Portable compressor: 4.6 m3/min. including tools and hoses Hr 100 B Air compressor: 6 m3/min. including two hoses and tools Hr 100 C Concrete mixers: open drum o.30/0.20 m3 Hr 100 D Concrete mixer: open drum 0.20/0.15 m3 Hr 100 E Dumpers 0.53 m3 capacity Hr 100 F Dumpers 1.00 m3 capacity Hr 100 G Concrete vibrator poker 50 mm diameter, electric backactor Hr 100 H Excavators: 0.50 m3 bucket capacity Hr 100 J Excavators: 1.0 m3 bucket capacity Hr 100 K Mobile crane, 10 tone capacity Hr 100 L Generator sets: 50 KVA Hr 100 M Generator sets: 10 KVA Hr 100 N Water pumps 25 KW Hr 100 P Van or utility vehicle, 1.5 tonne pickup Hr 100 Q Three tonne pickup Hr 100 R Water tanker: 4000 gal. capacity Hr 100 S 20 tonne tipper truck Hr 100 T 30 tonne tipper truck Hr 100 U Concrete pump Hr 100 V Welding and cutting set Hr 100 W Scaffold, mobile tower 5.0 m high Hr 100 TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.5 BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.5 Code Description Note: SCHEDULE OF RATES FOR DAYWORKS (Cont'd) Note: COLLECTION Note: LABOUR Code Description Remarks Unit of Measurement Quantity A Add for profit and overheads % DW-1 1 Code Description Note: Total for Labour Note: MATERIALS DELIVERED TO SITE Code Description Remarks Unit of Measurement Quantity B Add for profit and overheads % DW-2, DW-3 1 Code Description Note: Total for Materials Note: PLANT ON SITE Code Description Remarks Unit of Measurement Quantity C Add for profit and overheads % DW-4 1 Code Description Note: Total for Plant Note: Summary for Dayworks Note: A) Total For Labour Note: B) Total For Materials Delivered to Site Note: C) Total For Plant On Site TOTAL AMOUNT CARRIED TO TENDER (AED) Section total included in total? No TENDER SUMMARY TENDER SUMMARY Code Description Total carried to Tender TOTAL AMOUNT CARRIED TO TENDER (AED) * Bill No. 1 * Bill No. 2 * Bill No. 3 * Bill No. 4 * Bill No. 5 * Bill No. 6 * Bill No. 7 * Bill No. 8 Sub-Total Adjustment Item(In % if any)-Add*/Deduct % Amount after Adjustment (AED) Performanc Security Insurance of Work * Bill No. 9 Provisional Sum * Bill No. 10 Day Works Section total included in total? Yes Zoom 100% Zoom 75% Zoom 50% Zoom 25%
首轮成交额情景
AED 1,150,000–4,600,000情景按 1 个单位 × 假设单价 AED 1,000,000–4,000,000,加 15% 配套与交付测算。假设 1 个庇护设施施工交付包;公开摘要列有 BOQ,此情景尚未逐项计价,正式报价按 BOQ 和技术文件复核。 非采购方预算。
DOCUMENTS
公告与招标文件
在本页查看项目范围与合作安排。
参与合作
把项目编号、企业能力、相关业绩和交付计划发给我们。我们安排资格核对、采购范围确认和本地应标协调。
与我们合作 →这个项目采购什么,何时截标?
tender_241969 / rfq_246695 — 长者与有特殊需要人士庇护设施建设. Dubai Municipality. 2026-11-05 08:00 GST.
如何在这里阅读和下载项目文件?
在本页查看项目范围与合作安排。
与我们合作应准备哪些材料?
准备对应型号与规格、供货或施工业绩、本地交付计划及技术响应;按项目清单核对数量、验收和参与条件。
DIRECT ENQUIRY / 直接联系
项目咨询把合作需求发给我们。
招标合作请附项目编号与企业能力;礼赠合作请说明场景、数量和目标日期。我们确认方向、方案与报价,再推进执行。
发送电子邮件leon@aimuse.ae ↗
下载合作需求简表 ↓中国电话 / 微信15601678377微信与电话同号