BIN FARHOODالمشاريع وإدارة الأعمال في الإماراتابدأوا التعاون ↗
← العودة إلى فرص التعاون

ESUPPLY / tender_241969 / rfq_246695

ملاجئ لكبار السن وأصحاب الهمم

نطاق الشراء

رقم المشروع
tender_241969 / rfq_246695
الجهة المشترية
Dubai Municipality
النشر
2026-10-12
الإغلاق
2026-11-05 08:00 GST

ملاجئ لكبار السن وأصحاب الهمم

التحضير للعطاء

جهّزوا الطرازات والمواصفات المطابقة ومراجع التوريد أو الإنشاء وخطة التسليم المحلية والرد الفني؛ وراجعوا الكميات والقبول وشروط المشاركة وفق نطاق المشروع.

نص الإعلان
Project Details
Project Code
tender_241969
Project Title
PJ-30067 ELDERLY AND PEOPLE OF DETERMINATION  SHELTERS
Opportunity Details
Description
Note:: GENERAL REQUIREMENTS -
Note:: General Notes: -
Note:: ● Any items required in General requierments and has no item in BOQ will be considered subsidiary and included  in the prices of the other items). -
Note:: ● Total amount of General requierments must be not Exceeding 5 % of the Total amount of financial offer,if the Bidder failure to comply/adhere to the mentioned percentage , Dubai Municipality will entitled to reject the offer. -
Note:: Contractual Requirements -
Note:: Performance Security -
Note:: Note: DM will reimburse the CONTRACTOR for Performance Security fees at cost, supported by the surety’s invoice. For the avoidance of doubt, the amount specified in the Bill of Quantities is only indicative and shall not be paid to the Contractor.  -
Note:: The maximum amount for reimbursement of Performance Security fees shall not exceed the ceiling price, calculated as follows: Performance security amount = 0.3% x (number of quarters in contract period) x (bidder price) x 10% (performance security amount)  -
A: “Bidder is not required to price it ; the amount will be calculating automatically regarding to the equations in the Grand Summary and will be including in Bidder's total price ,  all conditions and requirements that mentioned in the Preamble will be applied.” - 1 Item
Note:: Insurance of the Works -
Note:: Note: DM will reimburse the CONTRACTOR for insurance of work fees at cost, supported by the invoice. For the avoidance of doubt, the amount specified in the Bill of Quantities is only indicative and shall not be paid to the Contractor. -
Note::  The maximum amount for reimbursement of insurance of work fees shall not exceed the ceiling price and the ceiling price shall be equal to 0.15% of the bidder price. -
B: “Bidder is not required to price it ; the amount will be calculating automatically regarding to the equations in the Grand Summary and will be including in Bidder's total price ,  all conditions and requirements that mention...
Notes
Supply Category
Other
Response Currency
AED
Opportunity Publication Date
12/10/2026 12:55
Closing date/time
05/11/2026 08:00
Published Lots
Published Lots
Row Number
Icon Column
Code
Title
Closing date/time
Action Column
1
RFQ/RFP
rfq_246695
PJ-30067 ELDERLY AND PEOPLE OF DETERMINATION SHELTERS
05/11/2026 08:00
Buyer Details
Buyer Organisation
Dubai Municipality
Contact
Email

Zoom 100%
Zoom 75%
Zoom 50%
Zoom 25%
Date & Time of Print: 13/10/2026 09:16:31 - Time Zone: Gulf Standard Time
Buyer Organisation: Dubai Municipality
Overview
Overview
RFQ/RFP Code
rfq_246695
Title
PJ-30067 ELDERLY AND PEOPLE OF DETERMINATION SHELTERS
Description
Status
Running
RFQ/RFP Settings
RFQ/RFP Settings
Online Response Required:
Yes
Event Currency
AED
RFQ/RFP Publication
12/10/2026 12:51
Closing
05/11/2026 08:00:00
Time Limit for Expressing Interest
05/11/2026 08:00:00
Awarding Strategy
Best Score
Additional Information
Section
Section Description
Tender Bond
Title
Description
Value Assigned by Buyer
Tender Bond Amount
Tender Bond Amount
260,000
Type of Invitation
Type of Invitation
Contractors
Invitation Letter
Invitation Letter
PJ-30067 Inv.Ltr rev.02.pdf
441 KB
Section
Section Description
PO Details
Title
Description
Value Assigned by Buyer
PO Number
PO Number

Envelopes
Envelopes
Qualification Envelope
Yes
Technical Envelope
Yes
Commercial Envelope
Yes
Qualification Envelope
Qualification Envelope
General Attachments
Not Allowed
Contact Details
Contact Details
Question
Description
Question Type
Contact Person Name
Please Enter Contact Person Name
Text
Contact Number
Please Enter a Direct / Mobile Contact Number
Text
Code of Conduct
Code of Conduct
Question
Description
Code of Conduct
على جميع الموردين الالتزام بمدونة مبادئ السلوك أثناء عملية إعداد وتقديم العروض والمقترحات أو أي إجراءات ذات علاقة مع البلدية وتعتبر جزء من الشروط العامة
All suppliers must adhere to the Code of Conduct during the process of preparing and submitting offers and proposals or any procedures related to the municipality and are considered part of the general conditions.
NDA
NDA
Question
Description
CONFIDENTIAL DISCLOSURE AGREEMENT
(NDA) على جميع الموردين الالتزام بتوقيع نموذج عدم الإفشاء
أثناء عملية إعداد وتقديم العروض مع البلدية وأرفاقه مع العرض المقدم وتعتبر جزء من الشروط العامة
All suppliers are obligated to sign a non-disclosure Agreement (NDA) during the process of preparing and submitting offers with Dubai Municipality and attached with the submitted offer form part of the general conditions
Tender Bond
Tender Bond
Question
Description
Tender Bond Form 2020
الضمان الابتدائي
Performance Bank Guarantee
Performance Bank Guarantee
Question
Description
Performance Bank Guarantee Form 2020
الضمان النهائي
Trade License
Trade License
Question
Description
Question Type
Trade License Classification
Please specify your Trade License type if its Local
Option List
Trade License Classification
If No please specify
Text
Sustainability
Sustainability
Question
Description
Sustainable Policy
سياسة الشراء المستدام
Criteria to evaluate DM suppliers’ commitment to apply sustainability
معايير تقييم التزام موردي بلدية دبي بتطبيق الاستدامة
قانون رقم ( 12 ) لسنة 2020 بشأن العُقود وإدارة المخازن في حُكومة دبي
قانون رقم ( 12 ) لسنة 2020 بشأن العُقود وإدارة المخازن في حُكومة دبي
Question
Description
قانون رقم ( 12 ) لسنة 2020
يرجى الاطلاع على القانون المستند عليه في إجراءات التعاقد في حكومة دبي
LAW ( 12 ) for the year 2020
Please find the attached Contracts and Warehouse Management in the Government of Dubai LAW 12 for the year 2020 that Dubai government uses as a reference in their contractual procedure
Information Security
Information Security
Question
Description
Information Security Article
وثيقة اشتراطات أمن المعلومات
إجراءات التظلم
إجراءات التظلم
Question
Description
إجراءات التظلم من القرارات الصادرة استناداً لقانون العقود وإدارة المخازن في حكومة دبي
عزيزي المورد في حال رغبتكم تقديم تظلم عن الإجراءات والجزاءات التعاقدية المتخذة بحقكم، يمكنكم تقديم خطاب تظلم مع المستندات الداعمة للجنة المختصة  وذلك خلال 30 يوم من تاريخ علمكم بالإجراءات المتخذة بحقكم
من خلال البريد الالكتروني cgc@dm.gov.ae
Contact Details
Contact Details
Question
Description
Question Type
Contact Person Name
Please Enter Contact Person Name
Text
Contact Number
Please Enter a Direct / Mobile Contact Number
Text
Code of Conduct
Code of Conduct
Question
Description
Code of Conduct
على جميع الموردين الالتزام بمدونة مبادئ السلوك أثناء عملية إعداد وتقديم العروض والمقترحات أو أي إجراءات ذات علاقة مع البلدية وتعتبر جزء من الشروط العامة
All suppliers must adhere to the Code of Conduct during the process of preparing and submitting offers and proposals or any procedures related to the municipality and are considered part of the general conditions.
NDA
NDA
Question
Description
CONFIDENTIAL DISCLOSURE AGREEMENT
(NDA) على جميع الموردين الالتزام بتوقيع نموذج عدم الإفشاء
أثناء عملية إعداد وتقديم العروض مع البلدية وأرفاقه مع العرض المقدم وتعتبر جزء من الشروط العامة
All suppliers are obligated to sign a non-disclosure Agreement (NDA) during the process of preparing and submitting offers with Dubai Municipality and attached with the submitted offer form part of the general conditions
Tender Bond
Tender Bond
Question
Description
Tender Bond Form 2020
الضمان الابتدائي
Performance Bank Guarantee
Performance Bank Guarantee
Question
Description
Performance Bank Guarantee Form 2020
الضمان النهائي
Trade License
Trade License
Question
Description
Question Type
Trade License Classification
Please specify your Trade License type if its Local
Option List
Trade License Classification
If No please specify
Text
SUSTAINABILITY
SUSTAINABILITY
Question
Description
Sustainable Policy
سياسة الشراء المستدام
Criteria to evaluate DM suppliers' commitment to apply sustainability
معايير تقييم التزام موردي بلدية دبي بتطبيق الاستدامة
قانون رقم ( 12 ) لسنة 2020 بشأن العُقود وإدارة المخازن في حُكومة دبي
قانون رقم ( 12 ) لسنة 2020 بشأن العُقود وإدارة المخازن في حُكومة دبي
Question
Description
قانون رقم ( 12 ) لسنة 2020
يرجى الاطلاع على القانون المستند عليه في إجراءات التعاقد في حكومة دبي
LAW ( 12 ) for the year 2020
Please find the attached Contracts and Warehouse Management in the Government of Dubai LAW 12 for the year 2020 that Dubai government uses as a reference in their contractual procedure
Noon Work Ban
Noon Work Ban
Question
Description
Noon Work Ban
حظر العمل وقت الظهيرة
Contact Details
Contact Details
Question
Description
Question Type
Contact Person Name
Please Enter Contact Person Name
Text
Contact Number
Please Enter a Direct / Mobile Contact Number
Text
Code of Conduct
Code of Conduct
Question
Description
Code of Conduct
على جميع الموردين الالتزام بمدونة مبادئ السلوك أثناء عملية إعداد وتقديم العروض والمقترحات أو أي إجراءات ذات علاقة مع البلدية وتعتبر جزء من الشروط العامة
All suppliers must adhere to the Code of Conduct during the process of preparing and submitting offers and proposals or any procedures related to the municipality and are considered part of the general conditions.
NDA
NDA
Question
Description
CONFIDENTIAL DISCLOSURE AGREEMENT
(NDA) على جميع الموردين الالتزام بتوقيع نموذج عدم الإفشاء
أثناء عملية إعداد وتقديم العروض مع البلدية وأرفاقه مع العرض المقدم وتعتبر جزء من الشروط العامة
All suppliers are obligated to sign a non-disclosure Agreement (NDA) during the process of preparing and submitting offers with Dubai Municipality and attached with the submitted offer form part of the general conditions
Tender Bond
Tender Bond
Question
Description
Tender Bond Form 2020
الضمان الابتدائي
Performance Bank Guarantee
Performance Bank Guarantee
Question
Description
Performance Bank Guarantee Form 2020
الضمان النهائي
Trade License
Trade License
Question
Description
Question Type
Trade License Classification
Please specify your Trade License type if its Local
Option List
Trade License Classification
If No please specify
Text
SUSTAINABILITY
SUSTAINABILITY
Question
Description
Sustainable Policy
سياسة الشراء المستدام
Criteria to evaluate DM suppliers' commitment to apply sustainability
معايير تقييم التزام موردي بلدية دبي بتطبيق الاستدامة
Contact Details
Contact Details
Question
Description
Question Type
Contact Person Name
Please Enter Contact Person Name
Text
Contact Number
Please Enter a Direct / Mobile Contact Number
Text
Code of Conduct
Code of Conduct
Question
Description
Code of Conduct
على جميع الموردين الالتزام بمدونة مبادئ السلوك أثناء عملية إعداد وتقديم العروض والمقترحات أو أي إجراءات ذات علاقة مع البلدية وتعتبر جزء من الشروط العامة
All suppliers must adhere to the Code of Conduct during the process of preparing and submitting offers and proposals or any procedures related to the municipality and are considered part of the general conditions.
NDA
NDA
Question
Description
CONFIDENTIAL DISCLOSURE AGREEMENT
(NDA) على جميع الموردين الالتزام بتوقيع نموذج عدم الإفشاء
أثناء عملية إعداد وتقديم العروض مع البلدية وأرفاقه مع العرض المقدم وتعتبر جزء من الشروط العامة
All suppliers are obligated to sign a non-disclosure Agreement (NDA) during the process of preparing and submitting offers with Dubai Municipality and attached with the submitted offer form part of the general conditions
Tender Bond
Tender Bond
Question
Description
Tender Bond Form 2020
الضمان الابتدائي
Performance Bank Guarantee
Performance Bank Guarantee
Question
Description
Performance Bank Guarantee Form 2020
الضمان النهائي
Trade License
Trade License
Question
Description
Question Type
Trade License Classification
Please specify your Trade License type if its Local
Option List
Trade License Classification
If No please specify
Text
SUSTAINABILITY
SUSTAINABILITY
Question
Description
Sustainable Policy
سياسة الشراء المستدام
Criteria to evaluate DM suppliers' commitment to apply sustainability
معايير تقييم التزام موردي بلدية دبي بتطبيق الاستدامة
Technical Envelope
Technical Envelope
General Attachments
Allowed
Technical Proposal
Technical Proposal
Question
Description
Question Type
أهلية المقاول
الرخصة التجارية تتضمن الأنشطة المرتبطة بنوع المشروع
Attachment
أهلية المقاول
تقديم تقرير رواتب موظفي الشركة مصدق من وزارة العمل خلال آخر 6 أشهر(متوسط 90 فما فوق 5 نقاط ،80-90 3 نقاط أقل من 80 يستبعد ولايستكمل تقييمه)
Attachment
أهلية المقاول
مؤهلات وخبرات مدير المشروع / مهندس مدني : ( خبرة 10 سنوات بنفس المجال ):  بدون شهادات مهنية PMP  (2نقطة) أو (3نقاط ) في حال وجود شهادة مهنية  certified PMP (شريطة تقديم ما يثبت عمله في الشركة من : إقامة -بطاقة عمل ،مع تقديم تأكيد شهادات خبرة سابقة معتمدة داخل الدولة لمدة خمس سنوات )
Attachment
أهلية المقاول
مؤهلات وخبرات مهندس الميكانيك ( خبرة 10 سنوات بنفس المجال ):		 ( 3 نقطة )(شريطة تقديم ما يثبت عمله في الشركة من : إقامة -بطاقة عمل ،مع تقديم تأكيد شهادات خبرة سابقة معتمدة داخل الدولة لمدة خمس سنوات )
Attachment
أهلية المقاول
مؤهلات وخبرات مهندس الكهرباء  ( خبرة 10 سنوات بنفس المجال ): 		( 3 نقطة ) (شريطة تقديم ما يثبت عمله في الشركة من : إقامة -بطاقة عمل ،مع تقديم تأكيد شهادات خبرة سابقة معتمدة داخل الدولة لمدة خمس سنوات )
Attachment
أهلية المقاول
مؤهلات وخبرات حاسب كميات  بدون شهادات مهنية PMP  (0نقطة) أو (3نقاط ) في حال وجود شهادة مهنية  certified PMP ( خبرة 10 سنوات بنفس المجال ): 		( 3 نقطة )(شريطة تقديم ما يثبت عمله في الشركة من : إقامة -بطاقة عمل ،مع تقديم تأكيد شهادات خبرة سابقة معتمدة داخل الدولة لمدة خمس سنوات )
Attachment
أداء المقاول
الانطباع العام عن مدى التزام المقاول بمتطلبات التقديم وادراج الوثائق الداعمة
ممتاز 5 درجات
جيد جدا 3 درجات
جيد 1 درجة
Attachment
أداء المقاول
تطبيق المورد لمنظومة إدارية (جودة – صحة وسلامة – بيئة – غيرها) وفق متطلبات مواصفة دولية وحصوله على شهادة مطابقة معها (مثل مواصفات الأيزو أو المواصفات الأوروبية أو البريطانية)
وجود شهادة مطابقة مع مواصفة دولية مجددة 3 درجات
وجود شهادة مطابقة مع مواصفة دولية غير مجددة 2 درجتان
عدم وجود شهادة مطابقة مع مواصفة دولية صفر
Attachment
أداء المقاول
اثبات التعامل مع مصنعين محليين من إمارة  دبي عن طريق المقاولة من الباطن
Attachment
أداء المقاول
الشركات أعضاء مؤسسة محمد بن راشد لتنمية المشاريع الصغيرة والمتوسطة (SME)
أو إثبات الدعم لأعضاء مؤسسة محمد بن راشد لتنمية المشاريع الصغيرة والمتوسطة (SME)عن طريق المقاولة من الباطن
Attachment
أداء المقاول
متوسط تقييم المقاول لدى إدارة العقود والمشتريات
5 درجات اذا التقييم A
3 درجات اذا التقييم B
2 درجات اذا التقييم C
0 درجات اذا التقييم D
1 درجة اذا لا توجد مشاريع سابقة
Attachment
الوضع المالي للمقاول
سجل الشركة المالي في حسن الأداء من خلال تقديم تقرير حسابات معتمد من مكتب حسابات معتمد في آخر 5 سنوات (لكل سنة درجة)
Attachment
الوضع المالي للمقاول
تقييم شركة الاتحاد للتقييم الائتماني
4 درجات 746-900
3 درجات 711-745
2 درجات 651-710
يستبعد 541 - 650
يستبعد 541 ومادون
Attachment
الوضع المالي للمقاول
متوسط حجم  المشاريع السنوي خلال آخر 5 سنوات بالدرهم
ملاحظة: يعتمد على موازنة المشروع قيد التقييم
المتوسط≥ 300 مليون 5 درجات
200مليون ≤ المتوسط < 300 مليون 3 درجات
100مليون ≤ المتوسط < 200 مليون 2 درجتان
المتوسط < 100 مليون 1 درجة
Attachment
خبرات المقاول
الخبرات العامة (سنة تأسيس الشركة، المشاريع المنفذة أو قيد التنفيذ)  10 سنة 5 نقاط ، 5- 9 سنة 3 نقاط ، اقل من 5 سنة صفر
Attachment
خبرات المقاول
الخبرات المتخصصة (تنفيذ مشروعين مشابهين من حيث الطبيعة الفنية للمشروع في آخر 5 سنوات) بأداء جيد مع تقديم شهادات الانجاز
مشروعين 10 درجات
مشروع 5 درجات
Attachment
خبرات المقاول
الخبرات في إدارة الأمن والسلامة (إدارة الأمن والسلامة لمشروعين متشابهين)
تحقيق متطلبات الاستدامة والبيئة والصحة والسلامة المهنية (تقديم شهادات ايزو صالحة 5 / 2.5علامات ، شهادة منتهية 3/1.5 ، عدم تقديم شهادة صفر)
مشروعين 5 درجات
مشروع 2.5 درجات
Attachment
منهجية العمل
البرنامج الزمني
Attachment
منهجية العمل
التدفق المالي الشهري
Attachment
منهجية العمل
خطة إدارة العمالة
Attachment
منهجية العمل
خطة إدارة المواد والتوريدات
Attachment
المعدات
تقديم قائمة المعدات اللازمة لتنفيذ المشروع (ملك أو استئجار):  مثل خلاطة خرسانة عدد 2 نقطتين، شيول عدد 3 ( 3 نقاط) ، بوبكات عدد 2 نقطتين
Attachment
Commercial Envelope
Commercial Envelope
General Attachments
Allowed
VAT Registration Details
VAT Registration Details
Question
Description
Question Type
DM - Registration Number
Kindly insert your DM Registration Number
Text
DM - VAT Registration Number
Kindly insert your company VAT Registration Number
Text
DM - VAT Certificate
Kindly upload a copy of your company VAT registration certificate
Attachment
DM - VAT Exempt Evidence
If your company is exempted from VAT, kindly provide any evidence document
Attachment
Tender Bond
Tender Bond
Question
Description
Question Type
Tender Bond Copy
Please attach a copy of the Tender Bond here.
Attachment
Tender Bond Expiry
Please insert the Tender Bond Expiry date here.
Date
Question
Description
Tender Bond Hard Copy
يسلم أصل الشيك فقط في المبنى الرئيسي لبلدية دبي – الطابق الثالث مكتب رقم 321 وعلى المناقص تحميل نسخة من الضمان أو الشيك من خلال نظـــام التوريد الالكتروني لحكومة دبي قبل يوم واحد على الأقل من الموعد المحدد لإغلاق المناقصة
Only the original Cheque shall be delivered to Finance department (3rd Floor, Office No.321) located at Dubai Municipality headquarters. In addition to that, bidders are required to upload the copy of Tender Bond/Cheque into eSupply System at least one day before closing date.
Tender Bond amount
قيمة ضمان المناقصة: مبلغ مقطوع كما هو محدد في دعوة العطاء
Tender bond amount: lump sum amount as mentioned in invitation letter
BILL No. 01 - PRELIMINARIES - Page No. 1.1
BILL No. 01 - PRELIMINARIES - Page No. 1.1
Code
Description
Note:
GENERAL REQUIREMENTS
Note:
General Notes:
Note:
● Any items required in General requierments and has no item in BOQ will be considered subsidiary and included  in the prices of the other items).
Note:
● Total amount of General requierments must be not Exceeding 5 % of the Total amount of financial offer,if the Bidder failure to comply/adhere to the mentioned percentage , Dubai Municipality will entitled to reject the offer.
Note:
Contractual Requirements
Note:
Performance Security
Note:
Note: DM will reimburse the CONTRACTOR for Performance Security fees at cost, supported by the surety’s invoice. For the avoidance of doubt, the amount specified in the Bill of Quantities is only indicative and shall not be paid to the Contractor.
Note:
The maximum amount for reimbursement of Performance Security fees shall not exceed the ceiling price, calculated as follows: Performance security amount = 0.3% x (number of quarters in contract period) x (bidder price) x 10% (performance security amount)
Code
Description
Remarks
Unit of Measurement
Quantity
A
“Bidder is not required to price it ; the amount will be calculating automatically regarding to the equations in the Grand Summary and will be including in Bidder's total price ,  all conditions and requirements that mentioned in the Preamble will be applied.”
Item
1
Code
Description
Note:
Insurance of the Works
Note:
Note: DM will reimburse the CONTRACTOR for insurance of work fees at cost, supported by the invoice. For the avoidance of doubt, the amount specified in the Bill of Quantities is only indicative and shall not be paid to the Contractor.
Note:
The maximum amount for reimbursement of insurance of work fees shall not exceed the ceiling price and the ceiling price shall be equal to 0.15% of the bidder price.
Code
Description
Remarks
Unit of Measurement
Quantity
B
“Bidder is not required to price it ; the amount will be calculating automatically regarding to the equations in the Grand Summary and will be including in Bidder's total price ,  all conditions and requirements that mentioned in the Preamble will be applied.”
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 01 - PRELIMINARIES - Page No. 1.2
BILL No. 01 - PRELIMINARIES - Page No. 1.2
Code
Description
Note:
GENERAL REQUIREMENTS (Cont'd)
Note:
Contractual Requirements(Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Third Party Liability Insurance
Item
1
B
Workmen's Compensation Insurance
Item
1
Code
Description
Note:
Specified Requirements
Note:
Accommodation for the Engineer's Staff
Code
Description
Remarks
Unit of Measurement
Quantity
C
Establishment of offices
Item
1
D
Maintenance of offices
Day
365
E
Removal of offices
Item
1
Code
Description
Note:
Sundry Items
Note:
Testing of Materials
Code
Description
Remarks
Unit of Measurement
Quantity
F
Arrange and carry out all specified tests and trails to materials including all necessary provision of samples for the following items all in accordance with Specification
Item
1
G
Set of monthly reports
Month
12
H
Co-ordinate with Service Authorities (DEWA, ETISALAT, RTA, DM Drainage & Irrigation Department, Building Dept. etc.) for obtaining  and maintaining  all NOCs, Building Permit, Green Building approvals etc. and pay all relevant fees
Item
1
Code
Description
Note:
As-Built drawings and Operations & Maintenance Manual
Code
Description
Remarks
Unit of Measurement
Quantity
J
Allow for providing as-built drawings and operations & maintenance manualAllow for providing as-built drawings and operations & maintenance manual
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 01 - PRELIMINARIES - Page No. 1.3
BILL No. 01 - PRELIMINARIES - Page No. 1.3
Code
Description
Note:
GENERAL REQUIREMENTS (Cont'd)
Note:
Temporary Works
Note:
Project Sign Board
Code
Description
Remarks
Unit of Measurement
Quantity
A
Erection of Project Sign Board, as detailed
Item
1
B
Maintenance
Days
365
C
Removal
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - SITE WORK - Page No. 2.1
BILL No. 02 - SITE WORK - Page No. 2.1
Code
Description
Note:
DIVISION 02 - SITE WORKS
Note:
Site Preparation
Code
Description
Remarks
Unit of Measurement
Quantity
A
Site Clearance, including removal of rubbish, debris, vegetation, within the designated work area complete accordance with the specifications and drawings
m2
1,688
Code
Description
Note:
Excavation
Note:
Excavation from existing level to bottom of foundation levels complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Bulk Excavation
m3
422
C
Pit Excavation
m3
708
D
Trench Excavation
m3
83
Code
Description
Note:
Backfilling
Code
Description
Remarks
Unit of Measurement
Quantity
E
Backfilling, including compaction in layer complete in accordance with specifications and drawings
m3
453
Code
Description
Note:
Disposal of Material Arising From Excavations
Code
Description
Remarks
Unit of Measurement
Quantity
F
Remove surplus excavated material from site to approved location complete in accordance with specifications and drawings
m3
760
Code
Description
Note:
Road base
Code
Description
Remarks
Unit of Measurement
Quantity
G
Road base, including compaction in layer complete in accordance with specifications and drawings
m3
107
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - SITE WORK (CONT'D) - Page No. 2.2
BILL No. 02 - SITE WORK (CONT'D) - Page No. 2.2
Code
Description
Note:
DIVISION 02 - SITE WORKS(CONT'D)
Note:
Anti - Termite Treatment
Note:
Allow for anti termite treatment under blinding and around building complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Laid horizontally
m2
1,688
B
Laid vertically
m2
1,618
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - CONCRETE WORK - Page No. 3.1
BILL No. 02 - CONCRETE WORK - Page No. 3.1
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS
Note:
IN ACCORDANCE WITH SPECIFICATIONS AND DRAWINGS
Note:
Sub Structure
Note:
Plain concrete, C20/25 compressive strength with ordinary Portland cement, GGBS,  including shuttering,  additives, plasticizers, curing, vibrating,  and all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
100 mm thick Blinding
m3
192
Code
Description
Note:
Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating,   and all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Foundation
m3
145
C
Neck column
m3
14
D
Wall below grade
m3
2
E
Slab on grade
m3
193
F
Ground beam
m3
109
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - CONCRETE WORKS (Cont'd)- Page No. 3.2
BILL No. 02 - CONCRETE WORKS (Cont'd)- Page No. 3.2
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS ( CONT`D)
Note:
Sub Structure (Cont`d)
Note:
Steel reinforcement
Note:
High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420  N/mm2 for shear design complete in accordance with specification and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
A
8 mm diameter
kg
2
B
10 mm diameter
kg
4,843
C
12 mm diameter
kg
21,845
D
16 mm diameter
kg
17,402
E
20 mm diameter
kg
987
Code
Description
Note:
Shuttering
Note:
Temporary shuttering, standard finish complete in accordance with specifications and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
F
To sides of foundation
m2
260
G
To sides of neck columns
m2
148
H
To sides of wall below grade
m2
12
J
To sides of ground beams
m2
802
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - CONCRETE WORKS (Cont'd)- Page No. 3.3
BILL No. 02 - CONCRETE WORKS (Cont'd)- Page No. 3.3
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS ( CONT`D)
Note:
Super Structure
Note:
Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating,   and all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Columns
m3
49
B
Walls
m3
6
C
Slabs
m3
288
D
Beams
m3
32
E
Drop panel
m3
23
F
Parapet
m3
89
Code
Description
Note:
Steel reinforcement
Note:
High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420  N/mm2 for shear design  complete in accordance with specification and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
G
8 mm diameter
kg
7
H
10 mm diameter
kg
9,505
J
12 mm diameter
kg
48,482
K
16 mm diameter
kg
10,859
L
20 mm diameter
kg
3,187
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - CONCRETE WORKS (Cont'd)- Page No. 3.4
BILL No. 02 - CONCRETE WORKS (Cont'd)- Page No. 3.4
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS ( CONT`D)
Note:
Super Structure (Cont'd)
Note:
Shuttering
Note:
Temporary shuttering, standard finish complete in accordance with specifications and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
A
To sides of columns
m2
535
B
To sides of walls
m2
43
C
To sides and soffits of slabs
m2
1,302
D
To sides and soffits of drop panel
m2
156
E
To sides and soffits of beams
m2
314
F
To sides of parapet
m2
890
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - CONCRETE WORKS (Cont'd)- Page No. 3.5
BILL No. 02 - CONCRETE WORKS (Cont'd)- Page No. 3.5
Code
Description
Note:
CONCRETE SUNDRIES
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for all joints including isolation, control, construction and contraction  joints or the like as required all in accordance with the specifications and drawings
Item
1
B
Allow for equipment base concrete as required all in accordance with the specifications and drawings
Item
1
C
Allow for concrete shaft cover as required all in accordance with the specifications and drawings
Item
1
D
Allow for structural opening for MEP services and networks throw slabs, beams, columns and foundations all in accordance with the specifications and drawings
Item
1
E
Allow for all builders work in connection with the whole of MEP works including all manholes, sumps, pits, etc.
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - MASONARY WORKS - Page No. 4.1
BILL No. 02 - MASONARY WORKS - Page No. 4.1
Code
Description
Note:
DIVISION 04 - MASONRY WORKS
Note:
External Block Work
Note:
External thermo solid normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref.WB03, 200mm thick
m2
31
Code
Description
Note:
External CMU solid block normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref.WB01, 100mm thick
m2
254.8
Code
Description
Note:
External CMU hollow normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Ref.WB04, 300mm thick
m2
369.52
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - MASONARY WORKS - Page No. 4.2
BILL No. 02 - MASONARY WORKS - Page No. 4.2
Code
Description
Note:
DIVISION 04 - MASONRY WORKS (CONT`D)
Note:
Internal Block Work
Note:
Internal hollow block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref.WB02, 150mm thick
m2
44
Code
Description
Note:
Thermo solid normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref.WB03, 200mm thick
m2
1,650
C
Ref.WB03*, 200mm thick , 1 H fire rated
m2
121
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - MASONARY WORKS - Page No. 4.3
BILL No. 02 - MASONARY WORKS - Page No. 4.3
Code
Description
Note:
DIVISION 04 - MASONRY WORKS (CONT`D)
Note:
Masonry Sundries
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for control joint complete in accordance with specification and drawing
Item
1
B
Allow for fire sealant complete in accordance with specification and drawing
Item
1
C
Allow for all opening and builder works for all MEP services in connection with masonry works all complete in accordance with specification and drawing
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - METAL WORK - Page No. 5.1
BILL No. 02 - METAL WORK - Page No. 5.1
Code
Description
Note:
DIVISION 05 - METAL WORKS
Note:
Non Structural Metal Work
Note:
Ladders
Note:
Supply and install galvanized steel ladder including rungs, side rails, safety cage, frame, steel brackets, supports, anchors, bolts, fixing, fittings, accessories and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. EF-07, Access cat ladder, 800x6010 mm height
No
1
Code
Description
Note:
Handrails and Balustrades
Note:
Supply and install  stainless steel balustrade pipe hand rail, grade 316,  including 30mm diameter stainless steel hand rail,  40mm diameter stainless steel top & bottom rails, base plate, fixing in position, fittings, accessories and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref.EF09, Stainless steel railing, 900mm high, for ramp
m
40
Code
Description
Note:
Aluminum Louver to MEP Equipment Area
Note:
Supply and install powder coated aluminium louver panels including aluminum frame and steel support, fixing in position, fittings, accessories and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Ref.EF06, Aluminum louver panel, size 2000 x 950mm high
No
2
D
Ditto, size 2000 x 2550mm high
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - METAL WORK - Page No. 5.2
BILL No. 02 - METAL WORK - Page No. 5.2
Code
Description
Note:
DIVISION 05 - METAL WORKS(CONT'D)
Note:
Stainless Steel Grating
Note:
Supply and install stainless tell grating including fixing in position, fittings, accessories and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
To Ablution, size-1500x550mm
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - WOOD WORKS - Page No. 6.1
BILL No. 02 - WOOD WORKS - Page No. 6.1
Code
Description
Note:
DIVISION 06 - WOOD WORKS
Note:
Supply and install wood cabinat, including hard board back panels, shelves, hinges, back splash, skirting, counter top, drawers, ironmongery, fittings, accessories, fixing and all necessary works complete in accordance with specifications and drawings ( counter top measured elsewhere)
Note:
Base unit
Code
Description
Remarks
Unit of Measurement
Quantity
A
Kitchen cabinat,  size 3420x 600 x 900mm high
No
1
Code
Description
Note:
Wall unit
Code
Description
Remarks
Unit of Measurement
Quantity
B
Kitchen cabinat,  size 3420x 350 x 700mm high
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.1
BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.1
Code
Description
Note:
DIVISION 07 - THERMAL & MOISTURE PROTECTION
Note:
Substructure Waterproofing
Note:
Supply and apply 1000guage polyethylene separation sheet, complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Laid horizontally, under slab on grade
m2
1,288
Code
Description
Note:
Supply and apply 1 layer of 4mm THK. each waterproofing membrane torch applied, complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Laid horizontally, under and above foundation
m2
710
Code / Note Title
Laid horizontally, under ground beam
m2
201
D
Laid vertically, side foundation
m2
260
E
Laid vertically, column neck and wall below grade
m2
160
F
Laid vertically, side ground beam
m2
802
Code
Description
Note:
Protection board
Note:
Supply and install seal tight protection board complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
G
Laid vertically & horizontally, 6mm thick
m2
1,570
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.2
BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.2
Code
Description
Note:
DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D)
Note:
Wet Area Waterproofing System
Note:
Supply and apply  SBS modified bitumen Jellfied emulion, 2 coats, to wet areas, including one coat primer with 20% water,  surface preparation and all necessary works complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Laid Horizontally
m2
116
B
Laid Vertically, 150mm high
m
210
Code
Description
Note:
Supply and install 3mm heavy duty damp proof membrane including surface preparation and all necessary works complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Laid Horizontally
m2
116
Code
Description
Note:
Supply and apply Light weight concrete,70mm thk. density 500 to 700KG/m laid to slope including surface preparation and all necessary works complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
D
Laid Horizontally
m2
116
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.3
BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.3
Code
Description
Note:
DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D)
Note:
Roof Waterproofing System
Note:
Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings
Note:
Laid Horizontally
Code
Description
Remarks
Unit of Measurement
Quantity
A
Roof cement tiles, Size 300x300
m2
1,278
B
Polyflex combo-top coat (1000 mic thick), sri > 78 as per green building regulation
m2
1,278
C
SBR bonding agent
m2
1,278
D
Concrete screed (26n/mm 2-350opc, 80mm ave. thickness)
m2
1,278
E
Polyfab filter membrane (1200mic thick)
m2
1,278
F
Polytex liquid U.V. protection coat ( 600mic thick)
m2
1,278
G
Polyurethane foam of thickness 110mm with  45-50kg/m  3density
m2
1,278
H
Light weight foam concrete, 50mm mni thickness. sloped to drain 2%
m2
1,278
J
Polybond bonding agent
m2
1,278
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.4
BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.4
Code
Description
Note:
DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D)
Note:
Roof Waterproofing System ( Cont`d)
Note:
Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings (Cont`d)
Note:
Laid Vertically
Code
Description
Remarks
Unit of Measurement
Quantity
A
Brush applied polytex -hr top coat (1000mic thick) sri > 78
m
1,141
B
Fabric reinforcement
m
1,141
C
Angle Fillet, 100x100mm
m
1,141
D
Polybond bonding agent
m
1,141
E
polyfab filter membrane (1200mic thick)
m
1,141
F
Polyurethane foam of thickness 110mm with  45-50kg/m  3density
m
1,141
G
Aluminum flashing
m
1,141
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.5
BILL No. 02 - THERMAL & MOISTURE PROTECTION - Page No. 7.5
Code
Description
Note:
DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D)
Note:
Sundries
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for waterproofing dressing around rain water outlet
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - DOORS & WINDOWS - Page No. 8.1
BILL No. 02 - DOORS & WINDOWS - Page No. 8.1
Code
Description
Note:
DIVISION 08 - DOORS AND WINDOWS
Note:
External Doors
Note:
Metal Doors
Note:
Supply and install metal doors with powder coated finish including frame, ironmongeries, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. MD-01, Double flush door, size 2000 x 2200mm high
No
2
Code
Description
Note:
Aluminium Doors
Note:
Supply and install aluminium doors with powder coated finish including frame, ironmongeries, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref. MD-02, Single flush door, size 1250 x 2200mm high
No
1
Code
Description
Note:
Internal Doors
Note:
Wooden Doors
Note:
Supply and install  solid core doors, hinged flush including 18mm thick marine plywood subframe,  38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer, ironmongeries, architrave, decorations, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
C
Ref. WD-02 ; Double leaf door size 1500 x 2200mm high, with concealed door closer
No
2
D
Ref. WD-02* ; Double leaf door size 1500 x 2200mm high, with concealed door closer, 45min fire rated
No
2
E
Ref. WD-07 ; single hinged door size 1250 x 2200mm high  , 45 min fire rated
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - DOORS & WINDOWS - Page No. 8.2
BILL No. 02 - DOORS & WINDOWS - Page No. 8.2
Code
Description
Note:
DIVISION 08 - DOORS AND WINDOWS(CONT'D)
Note:
Internal Doors  ( Cont`d)
Note:
Wooden Doors  ( Cont`d)
Note:
Supply and install  solid core doors, hinged flush including 18mm thick marine plywood subframe,  38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer, brushed stainless steel kick plate, ironmongeries, architrave, decorations, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings  ( Cont`d)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. WD-04 ; single hinged door size 1300 x 2200mm high, with concealed door closer
No
2
Code
Description
Note:
Supply and install  solid core doors, hinged flush including 18mm thick marine plywood subframe,  38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer, 6mm thick clear fire rated glass ( as per CD requirement), brushed stainless steel kick plate, ironmongeries, architrave, decorations, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref. WD-06 ; single hinged door size 1300 x 2200mm high, with concealed door closer,
No
2
C
Ref. WD-06* ; single hinged door size 1300 x 2200mm high, , with concealed door closer, 45 min fire rated
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - DOORS & WINDOWS - Page No. 8.3
BILL No. 02 - DOORS & WINDOWS - Page No. 8.3
Code
Description
Note:
DIVISION 08 - DOORS AND WINDOWS(CONT'D)
Note:
Internal Doors  ( Cont`d)
Note:
Wooden Doors  ( Cont`d)
Note:
Supply and install hinged flush wooden door including 18mm thick marine plywood subframe,  38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer,  brushed stainless steel kick plate, ironmongeries, architrave, decorations, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. WD-08 ; single hinged door size 1250 x 2200mm
No
18
Code
Description
Note:
Supply and install hinged flush wooden door including 18mm thick marine plywood subframe,  38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer, ironmongeries, architrave, decorations, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref. WD-03 ; single hinged door size 1300 x 2200mm high
No
2
C
Ref. WD-03* ; single hinged door size 1300 x 2200mm high  , 45 min fire rated
No
1
D
Ref.WD-05 ; Single hinged size 1300 X 2200mm high
No
19
E
Ref. WD-05* ; single hinged door size 1300 x 2200mm high , 45 min fire rated
No
12
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - DOORS & WINDOWS - Page No. 8.4
BILL No. 02 - DOORS & WINDOWS - Page No. 8.4
Code
Description
Note:
DIVISION 08 - DOORS AND WINDOWS(CONT'D)
Note:
Internal Doors  ( Cont`d)
Note:
Aluminium Doors
Note:
Supply and install aluminium doors with powder coated finish including frame, ironmongeries, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. MD-03, Double flush door, size 1250 x 2200mm high
No
2
Code
Description
Note:
Windows
Note:
Supply and install glazed aluminum windows including powder coated aluminum frames, Ironmongery, fittings, fire rating, acoustic insulation and all necessary accessories complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Window, size 1600 x 1500mm
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - DOORS & WINDOWS - Page No. 8.5
BILL No. 02 - DOORS & WINDOWS - Page No. 8.5
Code
Description
Note:
DIVISION 08 - DOORS AND WINDOWS(CONT'D)
Note:
Curtain Walls
Note:
Supply and install curtain wall system, 24mm thick double glazed, factory finished, comprising interior aluminum transom frames, aluminum mullions, double glazed, insulation, end mullions, aluminum sheet flashing and copping, caps, additional decorative frames, automatic/manual doors within curtain wall
Note:
with all accessories, U.V. resistant structural sealing compound, window, pre-filler, structural silicone, backing rod, gasketing, fire rating, hardware sets, all fitting and fixing accessories, complete as shown on detailed drawings and as per specifications.
Code
Description
Remarks
Unit of Measurement
Quantity
A
REF; CW 01,  size 2600mm x 4050mm including sliding door size 2025 x 4050mm
No
1
B
REF; CW 02, size 5400mm x 3350mm
No
1
C
REF; CW 03, size 2200mm x 3350mm including sliding door size 1325mm x 3350mm
No
12
D
Ref. CW04, size 1860mm x 3350mm, including single hinged door size 1050mm x 2475mm
No
2
E
REF; CW 05, size 6000mm x 3350mm
No
1
F
REF; CW 06, size 3400mm x 3350mm
No
1
G
REF; CW 07,  size 2700mm x 3350mm including sliding door size 1325mm x 3350mm
No
12
H
REF; CW 08, size 4000mm x 3350mm
No
1
J
REF; CW 10, size 2510mm x 4050mm
No
1
K
REF; CW 12,  size 4610mm x 3350mm
No
4
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - DOORS & WINDOWS - Page No. 8.6
BILL No. 02 - DOORS & WINDOWS - Page No. 8.6
Code
Description
Note:
DIVISION 08 - DOORS AND WINDOWS(CONT'D)
Note:
Curtain Walls (Cont`d)
Note:
Supply and install curtain wall system, 24mm thick double glazed, factory finished, comprising interior aluminum transom frames, aluminum mullions, double glazed, insulation, end mullions, aluminum sheet flashing and copping, caps, additional decorative frames, automatic/manual doors within curtain wall
Note:
with all accessories, U.V. resistant structural sealing compound, window, pre-filler, structural silicone, backing rod, gasketing, fire rating, hardware sets, all fitting and fixing accessories, complete as shown on detailed drawings and as per specifications (Cont`d)
Code
Description
Remarks
Unit of Measurement
Quantity
A
REF; CW 13, size 5560 x3350mm, including double leaf sliding door size 2150 x 2195mm
No
2
B
Ref.CW14, size 2000mm x 3350mm, sliding
No
2
C
Ref. CW 15  ;size 1500 x 3350mm high
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - FINISHES  - Page No. 9.1
BILL No. 02 - FINISHES  - Page No. 9.1
Code
Description
Note:
DIVISION 09 - FINISHES
Note:
Internal Finishes
Note:
Backgrounds
Note:
Floor Screed
Note:
Supply and install Cement and sand screed with self levelling compound; including sand filling, surface preparation, and all necessary works; complete all in according to drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
A
To receive porcelain tiles
m2
1,170
B
To receive carpet flooring
m2
36
C
To receive epoxy paint
m2
74
Code
Description
Note:
Plaster
Note:
Supply and install 20mm thick cement and sand plaster to block or concrete walls and columns including metal lath and all necessary works complete  in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
D
To receive wall paint
m2
2,359
E
To receive wall tile
m2
521
Code
Description
Note:
Supply and install cement sand plaster to soffits including all necessary works complete  in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
F
To receive paint finish
m2
74
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - FINISHES  - Page No. 9.2
BILL No. 02 - FINISHES  - Page No. 9.2
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
Internal Finishes  (Cont'd)
Note:
Internal Finishes
Note:
Floor Finishes
Note:
Supply and apply  Heavy duty free solvent epoxy coating including all necessary works complete in accordance with specifications and drawings (Screed measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref-FF04
m2
74
Code
Description
Note:
Supply and install porcelain tiles flooring including bedding materials, matching colored grout, polished, jointing  floor transition strips and acoustic underlay (where required) and all necessary works complete in accordance with specifications and drawings  (Screed measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref-FF01, porcelain tiles, Size 600x600mm
m2
1,058
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - FINISHES  - Page No. 9.3
BILL No. 02 - FINISHES  - Page No. 9.3
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
Internal Finishes (Cont'd)
Note:
Floor Finishes (Cont'd)
Note:
Supply and install Unglazed non skid Porcelain tiles flooring including bedding materials, matching colored grout, polished, jointing  floor transition strips and acoustic underlay (where required) and all necessary works complete in accordance with specifications and drawings  (Screed measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref-FF02, porcelain tiles, Size 300x300mm
m2
112
Code
Description
Note:
Supply and install carpet roll on terrazzo tiles, including cushion, trim accessories, acoustical underlayment's, and all necessary works complete in accordance with specifications and drawings   (Screed measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref-FF03, carpet roll on terrazzo tiles, 250x250x25mm
m2
36
Code
Description
Note:
Supply and install terrazzo tiles including  grouting, jointing, control joint, bedding material and all necessary works complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
C
Terrazzo tiles
m2
36
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - FINISHES  - Page No. 9.4
BILL No. 02 - FINISHES  - Page No. 9.4
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
Internal Finishes (Cont'd)
Note:
Floor Finishes (Cont'd)
Note:
Threshold
Note:
Supply and install  marble threshold including  bedding materials, waterproofing, grouting, jointing and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
200mm wide, 30mm thick
m
69
B
300mm wide, 30mm thick
m
97
Code
Description
Note:
Skirting
Note:
Supply and install porcelain tile skirting including backing, jointing and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Ref-Sk01,  high heavy duty porcelain tiles  skirting, 100mm
m
602
Code
Description
Note:
Walls Finishes
Note:
Supply and install porcelain wall tiling fixed with approved adhesive including backing, jointing, corner trim  and all necessary works complete in accordance with specifications and drawings (Plaster measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
D
Ref-WF-02, porcelain tiles, Size 300 x 600mm
m2
450
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - FINISHES  - Page No. 9.5
BILL No. 02 - FINISHES  - Page No. 9.5
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
Internal Finishes (Cont'd)
Note:
Ceiling Finishes
Note:
Supply and install 12mm thick gypsum board ceiling including access panel, suspension system, light cove, supports, channels, shadow gap, clips, angles, fixing, fittings and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref-CL-01
m2
1,041
Code
Description
Note:
Supply and install powder coated & anti bacteria aluminium tile ceiling including access panel, suspension system, supports, channels, clips, angles, fixing, fittings and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref-CL-02, Size 600 x 600mm
m2
103
Code
Description
Note:
Supply and install 12.5mm thick suspended gypsum board bulkhead including paint finish, suspension system, supports, fixing, fittings and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Gypsum bulkhead, Ref. CL-01 , 400mm high
m
83
D
Gypsum bulkhead, Ref. CL-01 , 550mm high
m
34.59
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - FINISHES  - Page No. 9.6
BILL No. 02 - FINISHES  - Page No. 9.6
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
Internal Finishes (Cont'd)
Note:
Painting and Decoration
Note:
Supply and install emulation high quality 100 % pure anti fungal & anti microbial (bacteria) highly washable paint , Matt finish, including backing, jointing, corner trim  and all necessary works complete in accordance with specifications and drawings (Plaster measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref-WF-01, Emulation paint
m2
2,104
Code
Description
Note:
Supply and install emulation  paint including  all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref-CL-03
m2
74
Code
Description
Note:
Supply and apply paint finish including surface preparation, primer coat, final coat and all necessary works complete in accordance with specifications  and drawings (Plaster measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
C
To gypsum board ceiling, paint Ref-CL-01
m2
1,041
D
To powder coated aluminum and anti bacteria ceiling tiles ,  Ref-CL-02
m2
103
E
T o bulk heads
m2
45.625
Code
Description
Note:
Supply and install anti-fungal paint including all necessary works complete in accordance with specifications  and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
F
To walls, above false ceiling wet areas
m2
255.97
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - FINISHES  - Page No. 9.7
BILL No. 02 - FINISHES  - Page No. 9.7
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
External Finishes
Note:
Backgrounds
Note:
Floor Screed
Note:
Supply and install Cement and sand screed with self levelling compound; including sand filling, surface preparation, and all necessary works; complete all in according to drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
A
To receive porcelain tiles
m2
70
Code
Description
Note:
Plaster
Note:
Supply and install cement and sand plaster to block or concrete walls and columns including metal lath and all necessary works complete  in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
To external block or concrete walls and columns, to receive paint finish
m2
1,190
C
To parapet , 20mm thick
m2
426
Code
Description
Note:
Floor Finishes
Note:
Supply and install porcelain tiles flooring including bedding materials, matching colored grout, polished, jointing  floor transition strips and acoustic underlay (where required) and all necessary works complete in accordance with specifications and drawings (screed measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
D
Ref-FF01, porcelain tiles, Size 600x600 , main entrance
m2
18.2
E
Ref-FF01, porcelain tiles, Size 600x600 , for ramp
m2
52
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - FINISHES  - Page No. 9.8
BILL No. 02 - FINISHES  - Page No. 9.8
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
External Finishes ( Cont`d)
Note:
Painting and Decoration
Note:
Supply and apply paint finish including surface preparation,  primer coat, final coat and all necessary works complete in accordance with specifications  and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
To plastered walls, Ref. EF 01
m2
1,190
B
To parapet walls & top, Ref. EF 01
m2
384
Code
Description
Note:
GRG Panels
Note:
Supply and install of GRG wall panels, CNC  with paint, including steel frame, base plates, anchor bolts, support and  fixing, fittings, accessories and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Ref; EF-02 , size 1100 X 3950mm
No
6
D
Ref; EF-02 , size 2100 X 3950mm
No
10
E
Ref; EF-02 , overall size 3300 X 3950mm, L-shaped
No
3
F
Ref; EF-02 , overall size  4200  X 3950mm, L-shaped
No
1
G
Ref; EF-02 , overall size 4400 X 3950mm, , L-shaped
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - FINISHES  - Page No. 9.9
BILL No. 02 - FINISHES  - Page No. 9.9
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
External Finishes ( Cont`d)
Note:
GRG Canopy
Note:
Supply and install of GRG canopy, CNC  with paint, including steel frame, base plates, anchor bolts, support and  fixing, fittings, accessories and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
REF, EF02 size 2500 X 1700 mm
No
1
B
REF, EF02  size 4400 X 4490 mm
No
1
C
REF, EF02 size 2000 X 3000 mm
No
6
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ACCESSORIES  - Page No. 10.1
BILL No. 02 - ACCESSORIES  - Page No. 10.1
Code
Description
Note:
DIVISION 10 - ACCESSORIES
Note:
Sanitary Fixture & Accessories
Note:
Supply and install sanitary fixtures and accessories including fittings, fixings, connections and all necessary works complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. STB003, security clothing hook welded to 5 mm thk clothing hook welded to 5mm thick steel plate.
No
5
B
Ref. TB008, foam soap
No
22
C
Ref. BD001,  Hand spray bidet
No
18
D
Ref. TB007, Free-standing Pedal Bin With removable
insert and Softclose
No
18
E
Ref. LAV001, wash basin
No
18
F
Ref. SH-001, Wall-mounted shower set with mixer, handheld shower, and adjustable rail
No
9
G
Ref. STB001, Toilet paper holder, stain steel recessed
No
18
H
Ref. STB005, Mediclinics steel paper
No
12
J
Ref. TB004, Medicare  Grab rail for wall mountain
No
2
K
Ref. TB005, Medicare grab rail for wall mounting, for barrier-free requirements, stainless steel
No
6
L
Ref. TB006, Grab bar manufactured by Mediclinics in steel bar Ø 32 mm vertical
No
2
M
Ref. FD 03; floor drain
No
22
N
Ref. WC-002; Wall-Hung Vitreous China Water Closet with Concealed tank Connection
No
18
P
Ref.FC-001; Single-lever basin mixer tap
No
17
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ACCESSORIES  - Page No. 10.2
BILL No. 02 - ACCESSORIES  - Page No. 10.2
Code
Description
Note:
DIVISION 10 - ACCESSORIES(CONT'D)
Note:
Sanitary Fixture & Accessories(Cont'd)
Note:
Supply and install sanitary fixtures and accessories including fittings, fixings, connections and all necessary works complete in accordance with the specifications and drawings(cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref.FD 01; 800mm Stainless Steel Linear Shower Drain (AXOR Finish Set)
No
9
B
Ref. FB001, Wall-Mounted Dual Flush Actuator Plate for Concealed Cistern
No
9
C
Circular wash basin
No
2
D
Wash basin
No
2
Code
Description
Note:
Mirrors
Note:
Supply and install mirror fixed on and including backing, frame, beveled edge and groove; all in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
E
Ref. TB-002, Size 600x900x8mm thick
No
4
Code
Description
Note:
Vanity Counters
Note:
Supply and install  vanity counters including fascia panel, splash back, supports, cut-out for wash basin, fittings, fixing, accessories, sealant and all necessary works complete in accordance with the specifications and drawings (wash basin measured elsewhere)
Code
Description
Remarks
Unit of Measurement
Quantity
F
Size 1500 x 600 x 250 mm with 1 No, cut basin , drop fascia 380mm
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ACCESSORIES  - Page No. 10.3
BILL No. 02 - ACCESSORIES  - Page No. 10.3
Code
Description
Note:
DIVISION 10 - ACCESSORIES(CONT'D)
Note:
Counters
Note:
Supply and install  counters including support, side finish, top finish, fittings, fixing, accessories, sealant and all necessary works complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
To kitchen cabinet at male wing common area size 3420x 600
No
1
Code
Description
Note:
Glass partitions
Note:
Supply and install glass partitions including doors, hardware, fixings, forming, openings, all fittings and accessories complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref.GLZ-01;  size 1900 x 3350mm, including single hinged door  size 1000 x 2200mm
No
1
C
Ref; PAR-05 , Glass partition 800 x 2000mm high
No
9
D
Ref. PAR-06, Glass partition size 2710mm x 2200mm including single hinged door size 1000mm x 2200 mm
No
2
E
Ref. PAR-01, Size  2700mm x 2200mm
No
1
F
Ref. PAR-06, Glass partition size 2750mm x 2200mm
No
1
G
Ref. PAR-02, size 3220 x 3000mm high including single hinged door size 1000 x 2200 mm H
No
2
H
Ref. PAR-03, Glass partition size 3620 x 2200mm high including single hinged door size 1000 x 2200 mm
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ACCESSORIES  - Page No. 10.4
BILL No. 02 - ACCESSORIES  - Page No. 10.4
Code
Description
Note:
DIVISION 10 - ACCESSORIES(CONT'D)
Note:
Ablution Seats
Note:
Supply and install  ablution seat including marble top, 20mm thick, ceramic tiles on mortar beds, reinforcement concrete, waterproofing, fixing, accessories, sealant and all necessary works complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ablution Seat
Item
1
Code
Description
Note:
Signage
Code
Description
Remarks
Unit of Measurement
Quantity
B
Supply and install signage including all fittings, fixings, support, accessories and all in accordance with specifications and drawings
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - FURNISHINGS - Page No. 12.1
BILL No. 02 - FURNISHINGS - Page No. 12.1
Code
Description
Note:
DIVISION 12 - FURNISHINGS
Note:
Loose Furnitures
Note:
Supply and install furniture including fittings, fixing, hardware, accessories and all related works, complete in accordance with drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. BD-01, Single Wooden Bedroom (1.00x2.20)m
No
9
B
Ref. BD-02, Clinic Bedroom (1.00x2.00)m
No
1
C
Ref. BT-01, Wooden Comod 400x400mm
No
3
D
Ref. CF-LCA-01, Base cabinet with laminate doors, solid-surface countertop, and drop-in sink
No
1
E
Ref. CF-UCA-01, Wall-mounted upper kitchen cabinet with hinged laminae doors
No
1
F
Ref. CH-01, Chair high bacl wooden leg
No
8
G
Ref. CH-02, Wooden office chair (0.65x0.65)m
No
9
H
Ref. CH-04, Wooden Chair with high long back leg
No
17
J
Ref. CH-05, Wooden table for four chair
No
12
K
Ref. CH-06, Ergonomic swivel office chair with armrests and headset
No
38
L
Ref. CP-01, Carpet (4x3)m
No
2
M
Ref. DSK-01, Wooden office desk (1.75x0.75)m
No
9
N
Ref. DSK-02, Wooden office chair (2.5x0.75)m
No
1
P
Ref. DT-02, Wooden table for four chair
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - FURNISHINGS - Page No. 12.2
BILL No. 02 - FURNISHINGS - Page No. 12.2
Code
Description
Note:
DIVISION 12 - FURNISHINGS (Cont'd)
Note:
Loose Furnitures (Cont'd)
Note:
Supply and install furniture including fittings, fixing, hardware, accessories and all related works, complete in accordance with drawings and specifications. (Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. F-B01, Double bed 1800x2100mm
No
1
B
Ref. F-B02, Bed Side (0.40x0.40)m
No
7
C
Ref. F-TB02, Wooden stand stable with glass
No
7
D
Ref. SF-01, Sofa for Reception area (2.40x1.00)m
No
2
E
Ref. SF-03, Reception wooden table (1.00x0.55)m
No
1
F
Ref. TB-01, Wooden stand stable with glass
No
8
G
Ref. TB-02, Wooden bedroom table (1.50x.50)m
No
9
H
Ref. TB-03, Wooden stand stable with glass
No
2
J
Ref. TB-04, meeting room table for 6 person
No
1
K
Ref. TB-06, Wooden office for staff room
No
8
L
Ref. TB-07, Sofa (1.85x0.75) m
No
3
M
Ref. TV-01, TV Reception area
No
2
N
Ref. TV-TB-01, Reception counter (1.40x0.501)m
No
2
P
Ref. WR-01, Deskdrawer for bedroom (2.30x0.55)m
No
8
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION - Page No. 15.1
BILL No. 02 -MECH INSTALLATION - Page No. 15.1
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS
Note:
Rainwater, soil,  waste, and vent pipework installations complete in accordance with specifications and drawings
Note:
Pipework
Note:
above ground uPVC pipework including fittings, accessories, insect screen, and all necessary works complete in accordance with drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
A
82mm diameter
m
34
B
110mm diameter
m
80
Code
Description
Note:
Under ground uPVC pipework including excavation, backfilling, warning tap, fittings, accessories, and all necessary works complete in accordance with drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
C
50mm diameter
m
115
D
82mm diameter
m
33
E
110mm diameter
m
215
Code
Description
Note:
Fittings, complete in accordance with drawings and specifications
Note:
Rain Water Drain
Code
Description
Remarks
Unit of Measurement
Quantity
F
Ref. RWO, 110mm diameter
No
16
Code
Description
Note:
Floor Drain
Code
Description
Remarks
Unit of Measurement
Quantity
G
Ref. FD, 150x150mm
No
25
Code
Description
Note:
Floor Cleanout
Code
Description
Remarks
Unit of Measurement
Quantity
H
Ref. FCO 110mm diameter
No
25
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.2
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.2
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Vent Cowl
Code
Description
Remarks
Unit of Measurement
Quantity
A
Size 110mm
No
2
B
Size 82mm
No
8
Code
Description
Note:
Grating Cover
Code
Description
Remarks
Unit of Measurement
Quantity
C
Grating cover, size 1500x500mm
No
2
D
Grating cover, size 2000x500mm
No
2
E
Shower Grating, size 800x70mm
No
9
Code
Description
Note:
Domestic Hot and Cold Water Installation
Note:
Cold Water Supply System
Note:
Supply and install cold water PPR pipe works including necessary, fittings, valves and accessories, and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
F
20mm diameter
m
496
G
25mm diameter
m
41
H
32mm diameter
m
17
J
32mm diameter, circulation pipe
m
8
K
40mm diameter
m
37
L
40mm diameter, water transfer line
m
9
M
50mm diameter
m
44
N
65mm diameter
m
5
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.3
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.3
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Domestic Hot and Cold Water Installation
Note:
Hot & Return Water Supply System
Note:
Supply and install hot water PPR pipe works with insulation including necessary, fittings, valves and accessories, and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
20mm diameter
m
430
B
25mm diameter
m
37
C
32mm diameter
m
17
D
40mm diameter
m
19
Code
Description
Note:
Pumps
Note:
Supply, install test and commission water pumps set with control panels, fittings, supports, flexible connections, electrical works, vibration isolation, electronic pressure controller, pressure gauges, protections and all required components and accessories as per drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
E
Domestic water booster pump set, flow 1.60 L/S, head 2.50 Bar, (1 Duty, 1 Standby).
No
2
F
Domestic water circulation pump set, flow 1.60 L/S, head 2.50 Bar, (1 Duty, 1 Standby).
No
2
Code
Description
Note:
Hot Water Pump
Code
Description
Remarks
Unit of Measurement
Quantity
G
Hot water return pump set, capacity 1.60 L/s @ 2.50 Bar head, (1 Duty, 1 Standby)
No
2
Code
Description
Note:
Pressure Vessel
Code
Description
Remarks
Unit of Measurement
Quantity
H
Pressure vessel 100 liters
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.4
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.4
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Domestic Hot and Cold Water Installation (Cont'd)
Note:
Demotic Water Tank
Note:
GRP hot pressed panel type, sectional insulated water tank including connections, float valve, pipes, access panel, fitting, accessories  and valves and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Size 4.0 x 2.50 x 1.50 m, capacity 15.0 m3
No
1
Code
Description
Note:
Solar System
Note:
Supply, install, test and commission flat plate solar system. Including collectors, tanks, short pipes, vent, valves, complete with all fittings, supports and all required accessories as per drawings & specifications.
Code
Description
Remarks
Unit of Measurement
Quantity
B
Flat plate solar system, (3 Collectors)
No
1
Code
Description
Note:
UV Sterilization Unit
Note:
Supply, install test and commission UV Sterilization complete with  all required components and accessories as per drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
C
UV sterilization unit, 1.6 L/s
No
1
Code
Description
Note:
Domestic Cooler Unit
Note:
Supply, install test and commission domestic cooler unit complete with valves, fittings, supports, electrical works, and all required components and accessories as per drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
D
Cooler unit, cooling capacity 10.5kw
No
1
Code
Description
Note:
Estidama Water Meter
Code
Description
Remarks
Unit of Measurement
Quantity
E
Estidama water meter, ref EWM-01
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.5
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.5
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Domestic Hot and Cold Water Installation (Cont'd)
Note:
Isolating Valves
Code
Description
Remarks
Unit of Measurement
Quantity
A
15mm diameter
No
4
B
20mm diameter
No
53
C
25mm diameter
No
3
D
32mm diameter
No
7
E
40mm diameter
No
1
F
50mm diameter
No
4
G
65mm diameter
No
1
Code
Description
Note:
Bib Tap
Code
Description
Remarks
Unit of Measurement
Quantity
H
15mm diameter
No
4
Code
Description
Note:
Ball Valves
Code
Description
Remarks
Unit of Measurement
Quantity
J
20mm diameter
No
17
Code
Description
Note:
Gate Valves
Code
Description
Remarks
Unit of Measurement
Quantity
K
25mm diameter
No
3
L
40mm diameter
No
3
Code
Description
Note:
Water Hammer Arrestor
Code
Description
Remarks
Unit of Measurement
Quantity
M
20mm diameter
No
38
Code
Description
Note:
Mixing valve
Code
Description
Remarks
Unit of Measurement
Quantity
N
Thermostatic mixing valve setting temperature @ 46.0C, 32mm diameter
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.6
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.6
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Fire Fighting System
Note:
Supply and install black  steel fire fighting water pipe works including drain pipes, fittings, accessories valve and supports and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
25mm diameter
m
413
B
25mm diameter, drain pipe
m
1
C
32mm diameter
m
19
D
40mm diameter
m
29
E
50mm diameter
m
27
F
65mm diameter
m
18
G
65mm diameter, wet riser pipe
m
27
H
80mm diameter
m
35
J
80mm diameter, wet riser pipe
m
17
K
100mm diameter
m
7
L
150mm diameter
m
31
Code
Description
Note:
Fire Hose Cabinet
Note:
Supply, install, test and commission hose station consist of a 25 mm hose reel & a 65 mm diameter landing valve including but not limited to cabinets, reels, fire extinguishers, isolating valves, pressure regulating valves, pressure reducing valves hoses, nozzles, marking, fixings, supports and all required components and accessories as per drawings, specifications and civil defense regulations.
Code
Description
Remarks
Unit of Measurement
Quantity
M
Ref FHC
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.7
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.7
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Fire Fighting System (Cont'd)
Note:
Frie Extinguisher
Note:
Supply install test and commission fire extinguisher including but not limited to wall fixing frame and hanger and all required components and accessories as per drawings, specifications and civil defense regulations.
Code
Description
Remarks
Unit of Measurement
Quantity
A
5 Kg dry CO2 fire extinguisher
No
4
B
4.5 Kg dry powder fire extinguisher
No
2
C
FFP foam trolly type 33 gal.
No
1
Code
Description
Note:
Fire Blanket
Note:
Supply and fix fire blanket  including all accessories and all necessary works complete in  accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
D
Fire Blanket, ref FB
No
1
Code
Description
Note:
Automatic Air Vent
Note:
Supply and install automatic air vent  including all accessories and all necessary works complete in  accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
E
Automatic air vent ref AAV, 150mm
No
1
Code
Description
Note:
Sprinkler Heads
Note:
Supply and install Sprinkler Heads including all fittings and  accessories complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
F
Pendant sprinkler head
No
139
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.8
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.8
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Fire Fighting System (Cont'd)
Note:
Valves and other fittings complete in accordance with specification and drawings
Note:
Zone Control Valve
Code
Description
Remarks
Unit of Measurement
Quantity
A
ZCV, 150mm
No
1
Code
Description
Note:
Pressure Reducing Valve
Code
Description
Remarks
Unit of Measurement
Quantity
B
PRV, 150mm
No
1
Code
Description
Note:
Non-Return Valve
Code
Description
Remarks
Unit of Measurement
Quantity
C
NRV, 150mm
No
1
Code
Description
Note:
Breeching Inlet
Code
Description
Remarks
Unit of Measurement
Quantity
D
150mm dia X 4 Way breeching inlet for sprinkler and wet riser systems
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.9
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.9
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation
Note:
Ductwork
Note:
Design, fabrication and installation of galvanized sheet metal ductwork including circular duct work, supports,  fittings and accessories, and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Supply duct
Kg
3,524
B
Return duct
Kg
846
C
Fresh duct
Kg
568
D
Exhaust duct
Kg
412
E
Toilet extract duct
Kg
837
F
Flexible supply air duct 200mm diameter
m
17
Code
Description
Note:
Internal Duct Insulation
Note:
Supply and install internal insulation for duct and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
G
For supply duct
m2
612
H
For return duct
m2
83
J
Toilet extract duct
m2
77
Code
Description
Note:
External Duct Insulation
Note:
Supply and install insulation for external duct with aluminum cladding and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
K
Supply duct
m2
42
L
Return duct
m2
41
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.10
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.10
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation (Cont'd)
Note:
External Duct Insulation (Cont'd)
Note:
Supply and install external insulation for duct and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
For fresh duct
m2
109
B
For exhaust duct
m2
84
C
Toilet extract duct
m2
107
Code
Description
Note:
Fresh Air Handling Unit
Note:
Supply and install fresh air handling units including connections to the ducts, controls, anti vibration mountings, thermostat, smoke detectors, sensors,  filters, coil, protective devices and drain and all necessary works complete in accordance with  specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
D
FAHU-01, air flow rate 1382 L/s,  cooling capacity 11.53 kw
No
1
Code
Description
Note:
Condensate Unit
Note:
Supply and install condensate unit including connections to the pipes, controls, anti vibration mountings, thermostat, smoke detectors, sensors,  filters, coil, protective devices and drain and all necessary works complete in accordance with  specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
E
CU/01-FAHU-01
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.11
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.11
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation(Cont'd)
Note:
Package Units
Note:
Supply, install, test and commission package unit, including but not limited to insulation, electrical and control wiring, cables, thermostats, control devices, supports, fittings, vibration isolation and all required components and accessories as per drawings, specifications and according to manufacturers requirements.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. 01-PU-01, flow rate 3932 L/s
No
1
B
Ref. 01-PU-02, flow rate 2327 L/s
No
1
C
Ref. 01-PU-03, flow rate 2198 L/s
No
1
D
Ref. 01-PU-04, flow rate 2836 L/s
No
1
E
Ref. 01-PU-05, flow rate 2327 L/s
No
1
Code
Description
Note:
Fans
Note:
Supply and install fans including connections, fittings, back draft, and accessories and all necessary works complete in accordance with  specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
F
Ref. 01-EXF-01, flow rate 600 L/s
No
2
Code
Description
Note:
Sound Attenuator
Code
Description
Remarks
Unit of Measurement
Quantity
G
Sound attenuator ref. SA, size 900x500mm
No
1
H
Sound attenuator ref. SA, size 900x600mm
No
1
J
Sound attenuator ref. SA, size 950x500mm
No
2
K
Sound attenuator ref. SA, size 950x700mm
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.12
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.12
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation(Cont'd)
Note:
Variable & Constant Air Volume System
Note:
Supply and install VAV/CAV box including connections, fittings, and accessories and all necessary works complete in accordance with  specification and drawings
Note:
Variable Air Volume
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. 01-VAV-01, flow rate 239 L/s
No
1
B
Ref. 01-VAV-02, flow rate 218 L/s
No
1
C
Ref. 01-VAV-03, flow rate 207 L/s
No
1
D
Ref. 01-VAV-04, flow rate 207 L/s
No
1
E
Ref. 01-VAV-05, flow rate 352 L/s
No
1
F
Ref. 01-VAV-06, flow rate 268 L/s
No
1
G
Ref. 01-VAV-07, flow rate 289 L/s
No
1
H
Ref. 01-VAV-08, flow rate 160 L/s
No
1
J
Ref. 01-VAV-09, flow rate 136 L/s
No
1
K
Ref. 01-VAV-10, flow rate 136 L/s
No
1
L
Ref. 01-VAV-11, flow rate 136 L/s
No
1
M
Ref. 01-VAV-12, flow rate 130 L/s
No
1
N
Ref. 01-VAV-13, flow rate 61 L/s
No
1
P
Ref. 01-VAV-14, flow rate 197 L/s
No
1
Q
Ref. 01-VAV-15, flow rate 61 L/s
No
1
R
Ref. 01-VAV-16, flow rate 123 L/s
No
1
S
Ref. 01-VAV-17, flow rate 136 L/s
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.13
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.13
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation (Cont'd)
Note:
Variable & Constant Air Volume System (Cont'd)
Note:
Variable Air Volume (Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. 01-VAV-18, flow rate 141 L/s
No
1
B
Ref. 01-VAV-19, flow rate 141 L/s
No
1
C
Ref. 01-VAV-20, flow rate 158 L/s
No
1
D
Ref. 01-VAV-21, flow rate 297 L/s
No
1
E
Ref. 01-VAV-22, flow rate 269 L/s
No
2
F
Ref. 01-VAV-23, flow rate 312 L/s
No
1
G
Ref. 01-VAV-24, flow rate 107 L/s
No
1
H
Ref. 01-VAV-25, flow rate 107 L/s
No
1
J
Ref. 01-VAV-26, flow rate 111 L/s
No
1
K
Ref. 01-VAV-27, flow rate 120 L/s
No
1
L
Ref. 01-VAV-28, flow rate 212 L/s
No
1
M
Ref. 01-VAV-29, flow rate 40 L/s
No
1
N
Ref. 01-VAV-30, flow rate 38 L/s
No
1
P
Ref. 01-VAV-31, flow rate 87 L/s
No
1
Q
Ref. 01-VAV-32, flow rate 87 L/s
No
1
R
Ref. 01-VAV-33, flow rate 128 L/s
No
1
S
Ref. 01-VAV-34, flow rate 512 L/s
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.14
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.14
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation(Cont'd)
Note:
Variable & Constant Air Volume System (Cont'd)
Note:
Constant Air Volume
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. 01-CAV-01, flow rate 86 L/s
No
1
B
Ref. 01-CAV-04, flow rate 113 L/s
No
1
C
Ref. 01-CAV-03, flow rate 138 L/s
No
1
D
Ref. 01-CAV-02, flow rate 38 L/s
No
1
E
Ref. 01-CAV-05, flow rate 36 L/s
No
1
F
Ref. 01-CAV-06, flow rate 60 L/s
No
1
G
Ref. 01-CAV-07, flow rate 145 L/s
No
1
H
Ref. 01-CAV-08, flow rate 35 L/s
No
1
J
Ref. 01-CAV-09, flow rate 454 L/s
No
2
K
Ref. 01-CAV-10, flow rate 140 L/s
No
1
Code
Description
Note:
DX Unit
Note:
Supply, install, test and commission  DX unit cooling only including but not limited to indoor & outdoor units, vibration isolation, control wiring, flexible connectors, integral control, hanger, supports, filters, sleeves, condensate piping and all required accessories as per drawings and specifications.
Code
Description
Remarks
Unit of Measurement
Quantity
L
Ref. 01-SP-01 / CU/01-SP-01, air side 2700 L/s
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.15
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.15
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation(Cont'd)
Note:
Dampers
Note:
Supply and install damper including connections, fittings and accessories and all necessary works complete in accordance with specification and drawings
Note:
Volume Control Damper
Code
Description
Remarks
Unit of Measurement
Quantity
A
Volume control damper ref. VCD size 100x100mm
No
2
B
Ditto ref. VCD size 150x100mm
No
20
C
Ditto ref. VCD size 150x150mm
No
4
D
Ditto ref. VCD size 200x150mm
No
5
E
Ditto ref. VCD size 200x200mm
No
1
F
Ditto ref. VCD size 250x150mm
No
7
G
Ditto ref. VCD size 250x200mm
No
4
H
Ditto ref. VCD size 250x250mm
No
1
J
Ditto ref. VCD size 300x200mm
No
7
K
Ditto ref. VCD size 350x150mm
No
1
L
Ditto ref. VCD size 350x200mm
No
7
M
Ditto ref. VCD size 350x250mm
No
2
N
Ditto ref. VCD size 400x200mm
No
1
P
Ditto ref. VCD size 400x250mm
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.16
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.16
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation(Cont'd)
Note:
Dampers (Cont'd)
Note:
Volume Control Damper (Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Volume control damper ref. VCD size 450x200mm
No
1
B
Ditto ref. VCD size 450x250mm
No
1
C
Ditto ref. VCD size 500x300mm
No
1
D
Ditto ref. VCD size 600x300mm
No
1
E
Ditto ref. VCD size 600x500mm
No
6
F
Ditto ref. VCD size 700x350mm
No
1
G
Ditto ref. VCD size 750x400mm
No
1
H
Ditto ref. VCD size 800x550mm
No
1
J
Ditto ref. VCD size 200mm diameter
No
37
Code
Description
Note:
Fire Damper
Code
Description
Remarks
Unit of Measurement
Quantity
K
Fire damper ref. FD, size 150x100mm
No
4
L
Ditto ref. FD, size 200x150mm
No
1
M
Ditto ref. FD, size 250x150mm
No
7
N
Ditto ref. FD, size 250x200mm
No
1
P
Ditto ref. FD, size 350x250mm
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.17
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.17
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation(Cont'd)
Note:
Dampers (Cont'd)
Note:
Fire Damper (Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Fire damper ref. FD, size 600x500mm
No
3
B
Ditto ref. FD, size 700x350mm
No
1
C
Ditto ref. FD, size 750x400mm
No
1
Code
Description
Note:
Motorized Damper
Code
Description
Remarks
Unit of Measurement
Quantity
D
Motorized damper ref. MD, size 200x150mm
No
1
E
Ditto ref. MD, size 250x150mm
No
1
F
Ditto ref. MD, size 300x200mm
No
1
G
Ditto ref. MD, size 350x150mm
No
2
H
Ditto ref. MD, size 350x200mm
No
2
J
Ditto ref. MD, size 350x250mm
No
1
K
Ditto ref. MD, size 450x200mm
No
1
L
Ditto ref. MD, size 450x250mm
No
1
M
Ditto ref. MD, size 450x350mm (NC)
No
1
N
Ditto ref. MD, size 450x350mm (NO)
No
1
P
Ditto ref. MD, size 700x400mm
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.18
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.18
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation(Cont'd)
Note:
Diffusers, Grills, Dampers, Liner diffusers
Note:
Supply and return air slot diffuser with integrated opposed blades volume damper and with adjustable deflection blades with 25mm thick acoustic one plenum box.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. SLD, 1000mm length, 1-slot
No
26
B
Ref. SLD, 1000mm length, 2-slots
No
11
C
Ref. RLD, 1000mm length, 1-slot
No
26
D
Ref. RLD, 1000mm length, 2-slots
No
11
Code
Description
Note:
Supply and return air diffuser
Code
Description
Remarks
Unit of Measurement
Quantity
E
Ref. SD 150x100mm
No
6
F
Ref. SD 150x150mm
No
3
G
Ref. SD 225x225mm
No
27
H
Ref. SD 300x300mm
No
16
J
Ref. RD 150x100mm
No
6
K
Ref. RD 150x150mm
No
3
L
Ref. RD 225x225mm
No
27
M
Ref. RD 300x300mm
No
16
Code
Description
Note:
Disk Valve
Code
Description
Remarks
Unit of Measurement
Quantity
N
Ref. DV 150mm diameter
No
20
Code
Description
Note:
Exhaust Diffuser
Code
Description
Remarks
Unit of Measurement
Quantity
P
Ref. EAD 150x150mm
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.19
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.19
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation(Cont'd)
Note:
Diffusers, Grills, Dampers, Liner diffusers(Cont'd)
Note:
Round supply and return air diffuser with adjustable butter fly control dampers(CONT'D)
Note:
Supply Grille
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. SG 150x100mm
No
2
B
Ref. SG 200x150mm
No
1
C
Ref. SG 250x150mm
No
3
D
Ref. SG 300x200mm
No
1
Code
Description
Note:
Return Grille
Code
Description
Remarks
Unit of Measurement
Quantity
E
Ref. RG 150x100mm
No
2
F
Ref. RG 200x150mm
No
1
G
Ref. RG 250x150mm
No
3
H
Ref. RG 300x200mm
No
1
Code
Description
Note:
Exhaust Air Louver
Code
Description
Remarks
Unit of Measurement
Quantity
J
EAL, with bird screen, 1245 L/s, face area 1.1m2
No
1
K
EAL, with bird screen, 575 L/s, face area 0.51m2
No
1
Code
Description
Note:
Fresh Air Louver
Code
Description
Remarks
Unit of Measurement
Quantity
L
FAL, with sand trap and insect screen, 1382 L/s, face area 1.5m2
No
1
Code
Description
Note:
Building Management System (BMS)
Code
Description
Remarks
Unit of Measurement
Quantity
M
Supply, install, test and commissioning  of Building management system including points, wires, conduits, and  all necessary works complete in accordance with specifications and drawings
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.20
BILL No. 02 -MECH INSTALLATION (Cont'd) - Page No. 15.20
Code
Description
Note:
Sundry / General Items
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for permits, connection and inspection fees associated with mechanical installations by utility and statutory authorities
Item
1
B
Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings
Item
1
C
Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment
Item
1
D
Allow for setting out the works, marking positions of holes, mortises, chases or the like
Item
1
E
Allow for testing and commissioning and submission of test certificates
Item
1
F
Allow for all identification labels, plates, charts and identification of plant, equipment, cable, isolators and the like
Item
1
G
Allow for preparing schedule of manufacturers recommended tools and spare parts for each piece of equipment
Item
1
H
Allow for the provision of operating/maintenance manuals
Item
1
J
Allow for providing shop and coordination drawings
Item
1
K
Allow for domestic water piping, sterilization and disinfections after commissioning
Item
1
L
Allow for flushing chilled water system pipe work  with water and establishment of rust inhibitor before commissioning
Item
1
M
Allow for fire stopping in accordance with the drawings, specification and local authorities requirements
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS
Note:
Power System installations
Note:
Automatic Transfer Switch (ATS)
Note:
Supply and  install automatic transfer switch including fixing, fittings, terminations, accessories and all necessary works  complete in accordance  with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
ATS 63A
No
1
Code
Description
Note:
Generator
Note:
Supply, install, test, commission and maintain, prime rated  generator including, but not limited to, lubrication system, control panels, fuel system and all associated devices and equipment, earthing, and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Standby diesel generator 24KW/30KVA
No
1
Code
Description
Note:
Main &Sub Main Distribution Boards
Note:
Supply, install, test, commission, and maintain main and sub-main distribution boards and terminations, including bus bars, breakers, indicators,  meters, all interconnecting cables, wires termination, energy monitoring meters, and trays from the main board,  and all necessary works complete in accordance with specification and drawings
Note:
Main Distribution Boards
Code
Description
Remarks
Unit of Measurement
Quantity
C
Main distribution boards, ref MDB-ELD
No
1
D
Ditto, ref MDB-ELD-AC
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Power System Installations (Cont'd)
Note:
Main &Sub Main Distribution Boards (Cont'd)
Note:
Supply, install, test, commission, and maintain main and sub-main distribution boards and terminations, including bus bars, breakers, indicators,  meters, all interconnecting cables, wires termination, energy monitoring meters, and trays from the main board,  and all necessary works complete in accordance with specification and drawings
Note:
Sub Main Distribution Boards
Code
Description
Remarks
Unit of Measurement
Quantity
A
Sub main distribution boards, ref ESMDB-ELD
No
1
Code
Description
Note:
Final Distribution Boards
Note:
Supply, install, test, commission and maintain Final Distribution boards and terminations including bus bars, breakers, indicators, all interconnecting cables, wires termination and trays from main board,  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Final distribution boards, DB-P1
No
1
C
Ditto, ref DB-P2
No
1
D
Ditto, ref DB-P3
No
1
E
Ditto, ref DB-L1
No
1
F
Ditto, ref EDB-L1
No
1
G
Lighting control panel, ref LCP
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Cable Tray
Note:
Supply and  install Cable trunk including fixing, fittings, accessories and all necessary works  complete in accordance  with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
200x100mm cable trunk
m
681
B
100x50mm cable trunk with cover
m
71
C
300x50mm cable trunk with cover
m
17
D
600x100mm cable trunk with cover
m
36
Code
Description
Note:
Cables
Note:
Low Voltage cables including ducts, glands, connections, conduits, termination, trays  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
E
2C.6 mm2 XLPE/SWA/PVC  +1C.6 mm2 PVC/ECC/CU
m
155
F
2C.6mm2 fire rated XLPE/SWA/PVC  +1C.6 mm2 fire rated PVC/ECC/CU
m
60
G
4C.10 mm2 XLPE/SWA/PVC  +1C.10 mm2 PVC/ECC/CU
m
189
H
4C.10 mm2 fire rated XLPE/SWA/PVC  +1C.10 mm2 fire rated PVC/ECC/CU
m
25
J
4C.16mm2 XLPE/SWA/PVC  +1C.16 mm2 PVC/ECC/CU
m
55
K
4C.16 mm2 fire rated XLPE/SWA/PVC  +1C.16 mm2 fire rated PVC/ECC/CU
m
12
L
4C.25mm2 XLPE/SWA/PVC  +1C.16 mm2 PVC/ECC/CU
m
213
M
4C.25 mm2 fire rated XLPE/SWA/PVC  +1C.16 mm2 fire rated PVC/ECC/CU
m
9
N
4C.50mm2 XLPE/SWA/PVC  +1C.25 mm2 PVC/ECC/CU
m
10
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Power Distribution
Note:
Supply and install the following power fittings including all necessary accessories and connections to wiring  and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
13A Single switched socket
No
56
B
13A Twin switched socket
No
49
C
13A Twin switched socket inside floor box
No
31
D
15A Switched socket
No
1
E
15A Switched socket inside floor box
No
3
F
13A Switched spur outlet
No
45
G
13A Unswitched spur outlet
No
19
H
20A double pole switch
No
17
Code
Description
Note:
Power point
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trucking, access box with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
J
Power points
No
221
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Power System Installations (Cont'd)
Note:
Floor Boxes
Note:
Supply, and install, floor boxes, including fixing, fitting, with all necessary works complete all in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Floor box with one compartment
No
3
B
Floor box with two compartments
No
31
Code
Description
Note:
Isolating Switch
Note:
Supply and install isolating switch  including all interconnecting and terminations  and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Isolator single phase 32A
No
2
D
Isolator single phase 32A IP65
No
3
E
Isolator three phase 32A IP65
No
5
F
Isolator three phase 40A
No
1
G
Isolator three phase 40A IP65
No
1
H
Isolator three phase 63A IP65
No
5
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Power System Installations (Cont'd)
Note:
Internal Lighting
Note:
Supply and install lighting including all necessary accessories  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Lighting fixture,  type S1
No
46
B
Ditto,  type S2
No
28
C
Ditto,  type S3
No
18
D
Ditto,  type S4
No
89
E
Ditto,  type S5
No
29
F
Ditto,  type S6
No
23
G
Ditto,  type S7
No
13
H
Ditto,  type S8
No
1
J
Ditto,  type W1
No
10
K
Ditto,  type L1
No
15
Code
Description
Note:
Internal Lighting Points
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
L
Internal Lighting points
No
272
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.7
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.7
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Power System Installations (Cont'd)
Note:
Switches
Note:
Supply, install, test, commission switches including all necessary accessories  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
One gang, one way lighting switch 20A
No
8
B
One gang, one way lighting switch 20A, W/P
No
3
C
Two gang, one way lighting switch 20A
No
15
D
Three gang, two way lighting switch 20A
No
18
E
One gang, one way override switch 20A
No
1
F
Two gang, one way override switch 20A
No
19
G
One gang, two way override switch 20A
No
6
H
Two gang, two way override switch 20A
No
6
J
Three gang, two way override switch 20A
No
2
K
Lux and absence multi sensor
No
12
L
Presence sensor
No
24
M
Motion sensor
No
24
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.8
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.8
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Power System Installations (Cont'd)
Note:
Switches (Cont'd)
Note:
Supply, install, test, commission switches including all necessary accessories  and all necessary works complete in accordance with specifications and drawings
Note:
Lighting switch Point
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Lighting switch points
No
78
B
Sensors points
No
60
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.9
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.9
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Emergency and Exit Lighting System
Note:
Supply, install, test, commission  the following emergency and exit light fittings, including  ceiling rose, heat resistance, flexible cable, lamps, electronic control gear, suspensions, connections to permanent wiring system in accordance with Specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Self-contained 1x8w emergency light with built-in battery (3h duration ), surface-mounted, non-maintained
No
5
B
Self-contained 1x8w emergency light with built-in battery (3h duration ), recessed mounted, non-maintained
No
36
C
Self-contained 1x8w  exit light maintained with a built-in battery (3h duration )
No
13
D
Self-contained 1x8w  exit light double-sided, maintained with a built-in battery (3h duration )
No
4
Code
Description
Note:
Emergency lighting points
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trunking, with all accessories,  and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
E
Emergency lighting points
No
58
Code
Description
Note:
Central Battery System
Note:
Supply and install central battery system including , pull boxes, junction boxes, wires,  and connections to relevant panel complete as shown on drawings and as per specifications
Code
Description
Remarks
Unit of Measurement
Quantity
F
Emergency light monitoring panel, ref EMP-ELD
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.10
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.10
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Fire Alarm System
Note:
Supply, install, test, commission and maintain  the complete Analogue addressable fire Alarm & evacuation system including cabling, wiring conduit, cable tray, trunking, termination and power connections  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Intelligent optical smoke detector and standard base
No
53
B
Smoke detector above ceiling void area
No
54
C
Intelligent heat detector with standard base
No
2
D
Intelligent optical smoke detector with sounder base
No
9
E
Manual call point
No
5
F
Fire alarm sounder with flasher
No
4
G
Fire alarm sounder or horn, W/P
No
6
H
Voice evacuation, ceiling mounted speaker
No
20
J
Desk type microphone for emergency voice broadcast
No
5
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.11
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.11
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Fire Alarm System (Cont'd)
Note:
Disabled Alarm System
Note:
Supply, install, test, commission and maintain  the complete Analogue addressable Disabled Alarm System including cabling, wiring conduit, cable tray, trunking, termination and power connections  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Reset point
No
2
B
Over light door & sounder unit above the door with WC sticker
No
2
C
disabled toilet alarm pull cord
No
2
D
standalone alarm controller & power supply
No
2
Code
Description
Note:
Supply, install, test, commission fire alarm control panel with charger and batteries, power supply, fire fighter two way communication, amplifiers, voice evac., alarm system, AUX. output, PC monitor and control, software, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
E
Fire alarm and voice evacuation integrated control panel, ref FACP-ELD, two loops
No
1
F
24/7 DCD monitoring panel
No
1
G
Voice evacuation control system, VECP-ELD
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.12
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.12
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Telecommunication System
Note:
Supply, install, test, commission  complete telecommunication system,  including cabling, wiring, conduits, cables, terminations and power connections  and all necessary works complete all in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Voice outlet (RJ45) wall mounted
No
18
B
Data outlet for wireless access point outlet ceiling based
No
9
C
Single data outlet (RJ45) wall mounted for IPTV
No
10
D
Dual (RJ45) data&voice socket outlet wall mounted
No
25
E
Dual data outlet inside floor box
No
31
F
Telephone outlet inside floor box
No
31
Code
Description
Note:
Communications Equipment
Note:
Supply and install of data and communication equipment and racks; including all kinds of cable, wires, cable trays,  and all required components, internal connections, all necessary support, fixings and accessories;  and all necessary works complete all in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
G
42U telephone rack
No
1
H
Proposed server rack at main server room
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.13
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.13
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
CCTV System
Note:
Supply install, test and commission complete CCTV system including rack, monitors, controllers , cabling, wiring, conduit and power connections, and all necessary works complete all in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
IP based identification dome camera
No
6
B
IP based recognition dome camera
No
23
C
IP based wall mounted weather proof bullet camera detection level
No
13
D
Future IP dome camera containment includes conduit and CAT6A cable
No
23
E
Provision for camera
No
12
Code
Description
Note:
CCTV Work Station
Note:
Supply and install CCTV works station, including, computer, screens, printers, and all necessary works complete all in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
F
CCTV work stations
No
2
Code
Description
Note:
Security Equipment
Note:
Supply and install of data and security equipment and racks; including all kinds of cable, wires, cable trays,  and all required components, internal connections, all necessary support, fixings and accessories;  and all necessary works complete all in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
G
Security rack 24U, ref MDF-SC-ELD
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.14
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.14
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Access Control System
Note:
Supply install, test and commission complete access control system including cabling, cable tray, wiring, conduit and power connections, and all necessary works complete all in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Master door control panel
No
1
B
Door control panel
No
11
C
Door contact
No
23
D
Electric mortise lock
No
15
E
Electro magnetic lock
No
7
F
Card reader
No
17
G
Exit push button
No
16
H
Break glass unit
No
16
Code
Description
Note:
Cable Tray
Note:
Supply and  install Cable trays including fixing, fittings, accessories and all necessary works  complete in accordance  with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
J
150x50mm HDGI cable tray for GSM
m
110
K
200x50mm HDGI cable tray for ICT
m
110
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.15
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.15
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Earthing protection system
Note:
Supply, install, test and commissioning of earthing protection system including earth pits, conductors, bars ,bonds and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Earthing protection
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.16
BILL No. 02 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.16
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Sundry / General Items
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for permits, connection and inspection fees associated with electrical installations by utility and statutory authorities
Item
1
B
Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings
Item
1
C
Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment
Item
1
D
Allow for setting out the works, marking positions of holes, mortises, chases or the like
Item
1
E
Allow for testing and commissioning and production of test certificates
Item
1
F
Allow for all identification labels, plates, charts and identification of plant, equipment, cable, switches and the like
Item
1
G
Allow for the provision of operating / maintenance manuals
Item
1
H
Allow for providing shop and coordination drawings
Item
1
J
Allow for instructing selected employer's personnel on all aspects of the operation of systems and equipment
Item
1
K
Supply and handover to the client all tools and equipment in accordance with the specification
Item
1
L
Allow for fire stopping in accordance with the drawings specification and local authorities requirements
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - SITE WORK - Page No. 2.1
BILL NO. 03 - SITE WORK - Page No. 2.1
Code
Description
Note:
DIVISION 02 - SITE WORKS
Note:
Site Preparation
Code
Description
Remarks
Unit of Measurement
Quantity
A
Site Clearance, including removal of rubbish, debris, vegetation, within the designated work area complete accordance with the specifications and drawings
m2
1,748
Code
Description
Note:
Excavation
Note:
Excavation from existing level to bottom of foundation levels complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Bulk Excavation
m3
437
C
Pit Excavation
m3
628
D
Trench Excavation
m3
62
Code
Description
Note:
Backfilling
Code
Description
Remarks
Unit of Measurement
Quantity
E
Backfilling, including compaction in layer complete in accordance with specifications and drawings
m3
366
Code
Description
Note:
Disposal of Material Arising From Excavations
Code
Description
Remarks
Unit of Measurement
Quantity
F
Remove surplus excavated material from site to approved location complete in accordance with specifications and drawings
m3
761
Code
Description
Note:
Road base
Code
Description
Remarks
Unit of Measurement
Quantity
G
Road base, including compaction in layer complete in accordance with specifications and drawings
m3
95
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - SITE WORK (CONT'D) - Page No. 2.2
BILL NO. 03 - SITE WORK (CONT'D) - Page No. 2.2
Code
Description
Note:
DIVISION 02 - SITE WORKS(CONT'D)
Note:
Anti - Termite Treatment
Note:
Allow for anti termite treatment under blinding and around building complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Laid horizontally
m2
1,748
B
Laid vertically
m2
1,485
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - CONCRETE WORK - Page No. 3.1
BILL NO. 03 - CONCRETE WORK - Page No. 3.1
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS
Note:
IN ACCORDANCE WITH SPECIFICATIONS AND DRAWINGS
Note:
Sub Structure
Note:
Plain concrete, C20/25 compressive strength with ordinary Portland cement, GGBS,  including shuttering,  additives, plasticizers, curing, vibrating,  and all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
100 mm thick Blinding
m3
201
Code
Description
Note:
Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating,   and all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Foundation
m3
128
C
Neck column
m3
12
D
Wall below grade
m3
1
E
Slab on grade
m3
217
F
Ground beam
m3
106
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - CONCRETE WORKS (Cont'd)- Page No. 3.2
BILL NO. 03 - CONCRETE WORKS (Cont'd)- Page No. 3.2
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS ( CONT`D)
Note:
Sub Structure (Cont`d)
Note:
Steel reinforcement
Note:
High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420  N/mm2 for shear design  complete in accordance with specification and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
A
8 mm diameter
kg
1
B
10 mm diameter
kg
4,685
C
12 mm diameter
kg
25,735
D
16 mm diameter
kg
14,121
E
20 mm diameter
kg
2,421
Code
Description
Note:
Shuttering
Note:
Temporary shuttering, standard finish complete in accordance with specifications and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
F
To sides of foundation
m2
230
G
To sides of neck columns
m2
137
H
To sides of wall below grade
m2
4
J
To sides of ground beams
m2
793
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - CONCRETE WORKS (Cont'd)- Page No. 3.3
BILL NO. 03 - CONCRETE WORKS (Cont'd)- Page No. 3.3
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS ( CONT`D)
Note:
Super Structure
Note:
Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating,   and all necessary works, complete in accordance with specifications and drawings (Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Columns
m3
45
B
Walls
m3
2
C
Slabs
m3
403
D
Beams
m3
25
E
Drop panel
m3
27
F
Parapet
m3
50
Code
Description
Note:
Steel reinforcement
Note:
High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420  N/mm2 for shear design complete in accordance with specification and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
G
8 mm diameter
kg
2
H
10 mm diameter
kg
15,059
J
12 mm diameter
kg
51,132
K
16 mm diameter
kg
9,650
L
20 mm diameter
kg
2,945
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - CONCRETE WORKS (Cont'd)- Page No. 3.4
BILL NO. 03 - CONCRETE WORKS (Cont'd)- Page No. 3.4
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS ( CONT`D)
Note:
Super Structure (Cont'd)
Note:
Shuttering
Note:
Temporary shuttering, standard finish complete in accordance with specifications and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
A
To sides of columns
m2
489
B
To sides of walls
m2
14
C
To sides and soffits of slabs
m2
1,476
D
To sides and soffits of drop panel
m2
184
E
To sides and soffits of beams
m2
253
F
To sides of parapet
m2
500
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - CONCRETE WORKS (Cont'd)- Page No. 3.5
BILL NO. 03 - CONCRETE WORKS (Cont'd)- Page No. 3.5
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS ( CONT`D)
A
CONCRETE SUNDRIES
Code
Description
Remarks
Unit of Measurement
Quantity
B
Allow for all joints including isolation, control, construction and contraction  joints or the like as required all in accordance with the specifications and drawings
Item
1
C
Allow for equipment base concrete as required all in accordance with the specifications and drawings
Item
1
D
Allow for concrete shaft cover as required all in accordance with the specifications and drawings
Item
1
D
Allow for structural opening for MEP services and networks throw slabs, beams, columns and foundations all in accordance with the specifications and drawings
Item
1
E
Allow for all builders work in connection with the whole of MEP works including all manholes, sumps, pits, etc.
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - MASONARY WORKS - Page No. 4.1
BILL NO. 03 - MASONARY WORKS - Page No. 4.1
Code
Description
Note:
DIVISION 04 - MASONRY WORKS
Note:
External Block Work
Note:
External CMU hollow normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref.W-04, 300mm thick
m2
367
Code
Description
Note:
External CMU solid block normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref.W-01, cavity Block 100mm thick including 60mm polystyrene insulation
m2
164
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - MASONARY WORKS - Page No. 4.2
BILL NO. 03 - MASONARY WORKS - Page No. 4.2
Code
Description
Note:
DIVISION 04 - MASONRY WORKS (CONT`D)
Note:
Internal Block Work
Note:
Internal hollow block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref.W-02, 150mm thick
m2
109
Code
Description
Note:
Thermo solid normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref.W-03, 200mm thick
m2
1,314
C
Ref.W-03*, 200mm thick, 1hr fire rated
m2
270
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - MASONARY WORKS - Page No. 4.3
BILL NO. 03 - MASONARY WORKS - Page No. 4.3
Code
Description
Note:
DIVISION 04 - MASONRY WORKS (CONT`D)
Note:
Masonry Sundries
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for control joint complete in accordance with specification and drawing
Item
1
B
Allow for fire sealant complete in accordance with specification and drawing
Item
1
C
Allow for all opening and builder works for all MEP services in connection with masonry works all complete in accordance with specification and drawing
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - METAL WORK - Page No. 5.1
BILL NO. 03 - METAL WORK - Page No. 5.1
Code
Description
Note:
DIVISION 05 - METAL WORKS
Note:
Non Structural Metal Work
Note:
Ladders
Note:
Supply and install galvanized steel ladder including rungs, side rails, safety cage, frame, steel brackets, supports, anchors, bolts, fixing, fittings, accessories and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. EF-10, Access cat ladder, 800 mm diameter x 5640 mm height
No
1
Code
Description
Note:
Handrails and Balustrades
Note:
Supply and install  stainless steel balustrade pipe hand rail, grade 316,  including 30mm diameter stainless steel hand rail,  40mm diameter stainless steel top & bottom rails, base plate, fixing in position, fittings, accessories and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
900mm high, for entrance ramp and step
m
102
Code
Description
Note:
Stainless Steel Grating
Note:
Supply and install stainless tell grating including fixing in position, fittings, accessories and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
To Ablution, size-1800x200mm
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - METAL WORK - Page No. 5.2
BILL NO. 03 - METAL WORK - Page No. 5.2
Code
Description
Note:
DIVISION 05 - METAL WORKS (CONT'D)
Note:
Non Structural Metal Work
Note:
Aluminum Powder Coated Cladding
Note:
Supply and install Aluminium powder coated cladding including frame, support, fixing in position, fittings, accessories and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref EF-07, 280x4000mm
No
1
B
Ref EF-07, 5360x1050mm
No
1
Code
Description
Note:
Aluminum Louvers
Note:
Supply and install aluminum louvers decorative powder coated aluminum screens, decorative powder coated aluminum frame and steel support  including   all fittings, accessories and fixings complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Ref. EF-08, Aluminum louvers, size 1600mm x 3350mm
No
1
D
Ditto, size 2000mm x 3350mm
No
1
E
Ditto, size 2010mm x 600mm
No
2
Code
Description
Note:
Supply and install powder coated aluminium louver panels including aluminum frame and steel support, fixing in position, fittings, accessories and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
F
Aluminum louver Panels, ref. EF-06, size 1000mm x 5200mm
No
3
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - METAL WORK - Page No. 5.3
BILL NO. 03 - METAL WORK - Page No. 5.3
Code
Description
Note:
DIVISION 05 - METAL WORKS (CONT'D)
Note:
Non Structural Metal Work (Cont'd)
Note:
Aluminium Powder Coated Canopy
Note:
Supply and install Aluminium powder coated canopy, including  steel box, galvanized beams supportive system, finishes, all fittings, accessories and fixings complete in accordance with specifications and drawings (Design by specialist)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Aluminium Canopy, size 1828x1810mm
No
1
B
Aluminium Canopy, size 9470x1510mm
No
1
C
Aluminium Canopy, L shaped  size 7080x650mm
No
1
D
Aluminium Canopy, L shaped  size 7520x1650mm
No
1
E
Aluminium Canopy, L shaped  size 7430x1650mm
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - WOOD WORKS - Page No. 6.1
BILL NO. 03 - WOOD WORKS - Page No. 6.1
Code
Description
Note:
DIVISION 06 - WOOD WORKS
Note:
Cabinets
Note:
Supply and install wood cabinet, including hard board back panels, shelves, hinges, back splash, skirting, counter top, drawers, ironmongery, fittings, accessories, fixing and all necessary works complete in accordance with specifications and drawings ( counter top measured elsewhere)
Note:
Base unit
Code
Description
Remarks
Unit of Measurement
Quantity
A
Base cabinet, size 3400x600x900mm high
No
3
B
L-shaped pantry cabinet, size 5000x600x900mm high
No
1
Code
Description
Note:
Wall unit
Code
Description
Remarks
Unit of Measurement
Quantity
C
Wall cabinet,  size 3400x 350 x 700mm high
No
1
D
L-shaped wall unit, size 5000x350x700mm high
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.1
BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.1
Code
Description
Note:
DIVISION 07 - THERMAL & MOISTURE PROTECTION
Note:
Substructure Waterproofing
Note:
Supply and apply 1000guage polyethylene separation sheet, complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Laid horizontally, under slab on grade
m2
1,443
Code
Description
Note:
Supply and apply 1 layer of 4mm THK. each waterproofing membrane torch applied, complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Laid horizontally, under and above foundation
m2
629
Code / Note Title
Laid horizontally, under ground beam
m2
195
D
Laid vertically, side foundation
m2
230
E
Laid vertically, column neck and wall below grade
m2
141
F
Laid vertically, side ground beam
m2
793
Code
Description
Note:
Protection board
Note:
Supply and install seal tight protection board complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
G
Laid vertically & horizontally, 6mm thick
m2
1,473
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.2
BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.2
Code
Description
Note:
DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D)
Note:
Wet Area Waterproofing System
Note:
Supply and apply  SBS modified bitumen Jellified emulsion, 2 coats, to wet areas, including one coat primer with 20% water,  surface preparation and all necessary works complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Laid Horizontally
m2
117
B
Laid Vertically, 150mm high
m
203
Code
Description
Note:
Supply and install 3mm heavy duty damp proof membrane including surface preparation and all necessary works complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Laid Horizontally
m2
112
Code
Description
Note:
Supply and apply Light weight concrete,70mm thk. density 500 to 700KG/m laid to slope including surface preparation and all necessary works complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
D
Laid Horizontally
m2
112
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.3
BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.3
Code
Description
Note:
DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D)
Note:
Roof Waterproofing System
Note:
Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings
Note:
Laid Horizontally
Code
Description
Remarks
Unit of Measurement
Quantity
A
Roof cement tiles, Size 300x300
m2
1,560
B
Polyflex combo-top coat (1000 mic thick), sri > 78 as per green building regulation
m2
1,560
C
SBR bonding agent
m2
1,560
D
Concrete screed (26n/mm 2-350opc, 80mm ave. thickness)
m2
1,560
E
Polyfab filter membrane (  1200mic thick)
m2
1,560
F
Polytex liquid U.V. protection coat ( 600mic thick)
m2
1,560
G
Polyurethane foam of thickness 110mm with  45-50kg/m  3density
m2
1,560
H
Light weight foam concrete, 50mm mni thickness. sloped to drain 2%
m2
1,560
J
Polybond bonding agent
m2
1,560
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.4
BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.4
Code
Description
Note:
DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D)
Note:
Roof Waterproofing System ( Cont`d)
Note:
Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings (Cont`d)
Note:
Laid Vertically
Code
Description
Remarks
Unit of Measurement
Quantity
A
Brush applied polytex -hr top coat ( 1000mic thick) sri > 78
m
286
B
Fabric reinforcement
m
286
C
Angle Fillet, 100x100mm
m
286
D
Polybond bonding agent
m
286
E
polyfab filter membrane (  1200mic thick)
m
286
F
Polyurethane foam of thickness 110mm with  45-50kg/m  3density
m
286
G
Aluminum flashing
m
286
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.5
BILL NO. 03 - THERMAL & MOISTURE PROTECTION - Page No. 7.5
Code
Description
Note:
DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D)
Note:
Sundries
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for waterproofing dressing around rain water outlet
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - DOORS & WINDOWS - Page No. 8.1
BILL NO. 03 - DOORS & WINDOWS - Page No. 8.1
Code
Description
Note:
DIVISION 08 - DOORS AND WINDOWS
Note:
External Doors
Note:
Metal Doors
Note:
Supply and install metal doors with powder coated finish including frame, ironmongeries, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. MD-01, Double flush door, size 2000 x 2200mm high
No
1
Code
Description
Note:
Aluminium Doors
Note:
Supply and install aluminium doors with powder coated finish including frame, ironmongeries, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref. MD-02, Single flush door, size 1250 x 2200mm high
No
1
Code
Description
Note:
Internal Doors
Note:
Wooden Doors
Note:
Supply and install  solid core doors, hinged flush including 18mm thick marine plywood subframe,  38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer, ironmongeries, architrave, decorations, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
C
Ref. WD-01 ; Double leaf door size 2000 x 2200mm high, with concealed door closer
No
1
D
Ref. WD-02 ; Double leaf door size 1500 x 2200mm high, with concealed door closer
No
7
E
Ref. WD-07 ; single hinged door size 1250 x 2200mm high  , 45 min fire rated
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - DOORS & WINDOWS - Page No. 8.2
BILL NO. 03 - DOORS & WINDOWS - Page No. 8.2
Code
Description
Note:
DIVISION 08 - DOORS AND WINDOWS(CONT'D)
Note:
Internal Doors  ( Cont`d)
Note:
Wooden Doors  ( Cont`d)
Note:
Supply and install  solid core doors, hinged flush including 18mm thick marine plywood subframe,  38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer, brushed stainless steel kick plate, ironmongeries, architrave, decorations, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings  ( Cont`d)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. WD-04 ; single hinged door size 1300 x 2200mm high, with concealed door closer
No
12
Code
Description
Note:
Supply and install  solid core doors, hinged flush including 18mm thick marine plywood subframe,  38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer, 6mm thick clear fire rated glass ( as per CD requirement), brushed stainless steel kick plate, ironmongeries, architrave, decorations, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref. WD-06 ; single hinged door size 1300 x 2200mm high, with concealed door closer,
No
2
C
Ref. WD-06* ; single hinged door size 1300 x 2200mm high, , with concealed door closer, 45 min fire rated
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - DOORS & WINDOWS - Page No. 8.3
BILL NO. 03 - DOORS & WINDOWS - Page No. 8.3
Code
Description
Note:
DIVISION 08 - DOORS AND WINDOWS(CONT'D)
Note:
Internal Doors  ( Cont`d)
Note:
Wooden Doors  ( Cont`d)
Note:
Supply and install hinged flush wooden door including 18mm thick marine plywood subframe,  38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer,  brushed stainless steel kick plate, ironmongeries, architrave, decorations, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. WD-08 ; single hinged door size 1250 x 2200mm high
No
6
Code
Description
Note:
Supply and install hinged flush wooden door including 18mm thick marine plywood subframe,  38mm thick semi-solid meranti wood frame with 4mm meranti wood veneer, ironmongeries, architrave, decorations, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref. WD-03 ; single hinged door size 1300 x 2200mm high
No
7
C
Ref. WD-03* ; single hinged door size 1300 x 2200mm high  , 45 min fire rated
No
3
D
Ref.WD-05 ; Single hinged size 1300 X 2200mm high
No
21
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - DOORS & WINDOWS - Page No. 8.4
BILL NO. 03 - DOORS & WINDOWS - Page No. 8.4
Code
Description
Note:
DIVISION 08 - DOORS AND WINDOWS(CONT'D)
Note:
Internal Doors  ( Cont`d)
Note:
Aluminium Doors
Note:
Supply and install aluminium doors with powder coated finish including frame, ironmongeries, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. MD-03, Double flush door, size 1250 x 2200mm high
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - DOORS & WINDOWS - Page No. 8.5
BILL NO. 03 - DOORS & WINDOWS - Page No. 8.5
Code
Description
Note:
DIVISION 08 - DOORS AND WINDOWS(CONT'D)
Note:
Curtain Walls
Note:
Supply and install curtain wall system, 24mm thick double glazed, factory finished, comprising interior aluminum transom frames, aluminum mullions, double glazed, insulation, end mullions, aluminum sheet flashing and copping, caps, additional decorative frames, automatic/manual doors within curtain wall
Note:
with all accessories, U.V. resistant structural sealing compound, window, pre-filler, structural silicone, backing rod, gasketing, fire rating, hardware sets, all fitting and fixing accessories, complete as shown on detailed drawings and as per specifications.
Code
Description
Remarks
Unit of Measurement
Quantity
A
REF; CW 01,  size 2600mm x 4000mm including sliding door size 2025 x 4050mm
No
1
B
REF; CW 02, size 5400mm x 3350mm
No
1
C
REF; CW 03, size 2200mm x 3350mm including sliding door size 1325mm x 3350mm
No
12
D
Ref. CW04, size 1860mm x 3350mm, including single hinged door size 1050mm x 2475mm
No
2
E
REF; CW 05, size 6000mm x 3350mm
No
1
F
REF; CW 06, size 3400mm x 3350mm
No
3
G
REF; CW 07,  size 2700mm x 3350mm including sliding door size 1325mm x 3350mm
No
6
H
REF; CW 08, size 4000mm x 3350mm
No
2
J
Ref. CW 09, size 2700x3350mm
No
2
K
REF; CW 10, size 2510mm x 4050mm
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - DOORS & WINDOWS - Page No. 8.6
BILL NO. 03 - DOORS & WINDOWS - Page No. 8.6
Code
Description
Note:
DIVISION 08 - DOORS AND WINDOWS(CONT'D)
Note:
Curtain Walls (Cont`d)
Note:
Supply and install curtain wall system, 24mm thick double glazed, factory finished, comprising interior aluminum transom frames, aluminum mullions, double glazed, insulation, end mullions, aluminum sheet flashing and copping, caps, additional decorative frames, automatic/manual doors within curtain wall
Note:
with all accessories, U.V. resistant structural sealing compound, window, pre-filler, structural silicone, backing rod, gasketing, fire rating, hardware sets, all fitting and fixing accessories, complete as shown on detailed drawings and as per specifications (Cont`d)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. CW 11, size 1900x3350mm
No
1
B
REF; CW 12,  size 4610mm x 3350mm
No
4
C
REF; CW 13, size 5560 x3350mm, including double leaf sliding door size 2150 x 2195mm
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - FINISHES  - Page No. 9.1
BILL NO. 03 - FINISHES  - Page No. 9.1
Code
Description
Note:
DIVISION 09 - FINISHES
Note:
Internal Finishes
Note:
Backgrounds
Note:
Floor Screed
Note:
Supply and install Cement and sand screed with self levelling compound; including sand filling, surface preparation, and all necessary works; complete all in according to drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
A
To receive porcelain tiles
m2
1,121
B
To receive carpet flooring
m2
138
C
To receive epoxy paint
m2
69
Code
Description
Note:
Plaster
Note:
Supply and install 20mm thick cement and sand plaster to block or concrete walls and columns including metal lath and all necessary works complete  in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
D
To receive wall paint
m2
2,824
E
To receive wall tile
m2
487
Code
Description
Note:
Supply and install cement sand plaster to soffits including all necessary works complete  in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
F
To receive paint finish
m2
67
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - FINISHES  - Page No. 9.2
BILL NO. 03 - FINISHES  - Page No. 9.2
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
Internal Finishes  (Cont'd)
Note:
Internal Finishes
Note:
Floor Finishes
Note:
Supply and apply  Heavy duty free solvent epoxy coating including all necessary works complete in accordance with specifications and drawings (Screed measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref-FF04
m2
69
Code
Description
Note:
Supply and install porcelain tiles flooring including bedding materials, matching colored grout, polished, jointing  floor transition strips and acoustic underlay (where required) and all necessary works complete in accordance with specifications and drawings  (Screed measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref-FF01, porcelain tiles, Size 600x600mm
m2
1,107
Code
Description
Note:
Supply and install Unglazed non skid Porcelain tiles flooring including bedding materials, matching colored grout, polished, jointing  floor transition strips and acoustic underlay (where required) and all necessary works complete in accordance with specifications and drawings  (Screed measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
C
Ref-FF02, porcelain tiles, Size 300x300mm
m2
104
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - FINISHES  - Page No. 9.3
BILL NO. 03 - FINISHES  - Page No. 9.3
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
Internal Finishes (Cont'd)
Note:
Floor Finishes (Cont'd)
Note:
Supply and install carpet roll on terrazzo tiles, including cushion, trim accessories, acoustical underlayment's, and all necessary works complete in accordance with specifications and drawings   (Screed measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref-FF03, carpet roll on terrazzo tiles, 250x250x25mm
m2
138
Code
Description
Note:
Supply and install terrazzo tiles including  grouting, jointing, control joint, bedding material and all necessary works complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
B
Terrazzo tiles
m2
138
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - FINISHES  - Page No. 9.4
BILL NO. 03 - FINISHES  - Page No. 9.4
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
Internal Finishes (Cont'd)
Note:
Threshold
Note:
Supply and install  marble threshold including  bedding materials, waterproofing, grouting, jointing and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
200mm wide, 30mm thick
m
4
B
300mm wide, 30mm thick
m
44
Code
Description
Note:
Skirting
Note:
Supply and install porcelain tile skirting including backing, jointing and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Ref-Sk01,  high heavy duty porcelain tiles  skirting, 100mm
m
796
Code
Description
Note:
Walls Finishes
Note:
Supply and install porcelain wall tiling fixed with approved adhesive including backing, jointing, corner trim  and all necessary works complete in accordance with specifications and drawings (Plaster measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
D
Ref-WF-02, porcelain tiles, Size 300 x 600mm
m2
467
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - FINISHES  - Page No. 9.5
BILL NO. 03 - FINISHES  - Page No. 9.5
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
Internal Finishes (Cont'd)
Note:
Ceiling Finishes
Note:
Supply and install 12mm thick gypsum board ceiling including access panel, suspension system, light cove, supports, channels, shadow gap, clips, angles, fixing, fittings and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref-CL-01
m2
1,210
Code
Description
Note:
Supply and install powder coated & anti bacteria aluminium tile ceiling including access panel, suspension system, supports, channels, clips, angles, fixing, fittings and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref-CL-02, Size 600 x 600mm
m2
102
Code
Description
Note:
Supply and install 12.5mm thick suspended gypsum board bulkhead including paint finish, suspension system, supports, fixing, fittings and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Gypsum bulkhead, Ref. CL-01 , 350mm high
m
3
C
Gypsum bulkhead, Ref. CL-01 , 400mm high
m
100
D
Gypsum bulkhead, Ref. CL-01 , 550mm high
m
35
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - FINISHES  - Page No. 9.6
BILL NO. 03 - FINISHES  - Page No. 9.6
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
Internal Finishes (Cont'd)
Note:
Painting and Decoration
Note:
Supply and install emulation high quality 100 % pure anti fungal & anti microbial (bacteria) highly washable paint , Matt finish, including backing, jointing, corner trim  and all necessary works complete in accordance with specifications and drawings (Plaster measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref-WF-01, Emulation paint
m2
2,789
Code
Description
Note:
Supply and install emulation  paint including  all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref-CL-03
m2
67
Code
Description
Note:
Supply and apply paint finish including surface preparation, primer coat, final coat and all necessary works complete in accordance with specifications  and drawings (Plaster measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
C
To gypsum board ceiling, paint Ref-CL-01
m2
1,210
D
To powder coated aluminum and anti bacteria ceiling tiles ,  Ref-CL-02
m2
102
E
T o bulk heads
m2
60
Code
Description
Note:
Supply and install anti-fungal paint including  all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
F
To walls, above false ceiling wet areas
m2
179
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - FINISHES  - Page No. 9.7
BILL NO. 03 - FINISHES  - Page No. 9.7
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
External Finishes
Note:
Backgrounds
Note:
Floor Screed
Note:
Supply and install Cement and sand screed with self levelling compound; including sand filling, surface preparation, and all necessary works; complete all in according to drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
A
To receive granite tiles
m2
103
Code
Description
Note:
Plaster
Note:
Supply and install cement and sand plaster to block or concrete walls and columns including metal lath and all necessary works complete  in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
To external block or concrete walls and columns, to receive paint finish
m2
1,641
C
To external block or concrete walls and columns, to receive Ribbed stone Tiles
m2
240
Code
Description
Note:
Floor Finishes
Note:
Supply and install granite tiles flooring including bedding materials, matching colored grout, polished, jointing  floor transition strips and acoustic underlay (where required) and all necessary works complete in accordance with specifications and drawings (screed measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
D
Ref-FF05, Granite tiles
m2
103
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - FINISHES  - Page No. 9.8
BILL NO. 03 - FINISHES  - Page No. 9.8
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
External Finishes (Cont`d))
Note:
Skirting
Note:
Supply and install  granite skirting including backing, adhesive and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref-SK-02, 100x600x20mm granite
m
5
Code
Description
Note:
Painting and Decoration
Note:
Supply and apply paint finish including surface preparation,  primer coat, final coat and all necessary works complete in accordance with specifications  and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
To plastered walls, Ref. EF 01
m2
1,641
Code
Description
Note:
Stone Cladding
Note:
Supply and install Ribbed stone tiles including backing, fixing, fittings and all necessary work, complete in accordance with specifications  and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
To external elevation, ref.EF 02, Ribbed stone tiles
m2
240
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - ACCESSORIES  - Page No. 10.1
BILL NO. 03 - ACCESSORIES  - Page No. 10.1
Code
Description
Note:
DIVISION 10 - ACCESSORIES
Note:
Sanitary Fixture & Accessories
Note:
Supply and install sanitary fixtures and accessories including fittings, fixings, connections and all necessary works complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. BD-001, Hand Spray Bidet
No
9
B
Ref. FB-001, Wall-mounted dual flush actuator plate for concealed cistern
No
14
C
Ref. FC-001, Single-lever basin mixer tap
No
14
D
Ref. FD01, 800mm Stainless steel linear shower drain(Axor finish set)
No
6
E
Ref. FD03, Floor drain
No
20
F
Ref. LAV-001, Wash basin
No
14
G
Ref. LAV-003, Wash basin 450x450
No
1
H
Ref. SH-001, Wall-mounted shower set with mixer handheld shower, and adjustable rail
No
6
J
Ref. STB-001, Toilet paper holder, stain steel recessed
No
14
K
Ref. STB-003, Security clothing hook
No
2
L
Ref. STB-005, Mediclinic steel paper
No
17
M
Ref. TB-004, Medicare grab rail for wall mountain
No
21
N
Ref. TB-005, Vertical grab rail for Toilet Handicap
No
27
P
Ref. TB-006, Grab bar manufactured by mediclinics in steel bar
No
6
Q
Ref. TB-007, Free-standing pedal bin with removable insert and softclose
No
14
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - ACCESSORIES  - Page No. 10.2
BILL NO. 03 - ACCESSORIES  - Page No. 10.2
Code
Description
Note:
DIVISION 10 - ACCESSORIES(CONT'D)
Note:
Sanitary Fixture & Accessories(Cont'd)
Note:
Supply and install sanitary fixtures and accessories including fittings, fixings, connections and all necessary works complete in accordance with the specifications and drawings(cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. TB-008, Foam soap
No
18
B
Ref. TB-009, Sanitary tap mixer
No
7
C
Ref. WC-002, wall hung vitreous china water closet with concealed tank connection
No
14
D
Sink
No
3
E
Circular Wash Basin
No
1
F
Vanity with counter
No
1
Code
Description
Note:
Mirrors
Note:
Supply and install mirror fixed on and including backing, frame, beveled edge and groove; all in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
G
Ref. TB-002, Size 600x900x8mm thick
Item
1
Code
Description
Note:
Vanity Counters
Note:
Supply and install  vanity counters including fascia panel, splash back, supports, cut-out for wash basin, fittings, fixing, accessories, sealant and all necessary works complete in accordance with the specifications and drawings (wash basin measured elsewhere)
Code
Description
Remarks
Unit of Measurement
Quantity
H
Size 1500 x 600 mm with 1 No, cut basin, 380mm drop fascia
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - ACCESSORIES  - Page No. 10.3
BILL NO. 03 - ACCESSORIES  - Page No. 10.3
Code
Description
Note:
DIVISION 10 - ACCESSORIES(CONT'D)
Note:
Glass partitions
Note:
Supply and install glass partitions including doors, hardware, fixings, forming, openings, all fittings and accessories complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. PAR-01, size 4305 x 3000 mm, including 1 No. door size 1100 x 2000 mm
No
1
B
Ref. PAR-02, size 4360 x 3000 mm, including 1 No. door size 1100 x 2000 mm
No
1
C
Ref. PAR-03, size 4255 x 3000 mm, including 1 No. door size 1100 x 2200 mm
No
1
D
Ref. PAR-04, size 3655 x 2200 mm, including 1 No. door size 1100 x 2200 mm
No
1
E
Ref. PAR-06, size 2710 x 2200 mm, including 1 No. door size 1210 x 2200 mm
No
2
F
Ref. PAR-07, size 2360 x 2200 mm, including 1 No. door size 1190 x 2200 mm
No
1
G
Ref. PAR-08, size 4350 x 3000 mm, including 1 No. door size 1185 x 2220 mm
No
1
Code
Description
Note:
Ablution Seats
Note:
Supply and install  ablution seat including marble top, 20mm thick, ceramic tiles on mortar beds, reinforcement concrete, waterproofing, fixing, accessories, sealant and all necessary works complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
H
Ablution Seat
Item
1
Code
Description
Note:
Signage
Code
Description
Remarks
Unit of Measurement
Quantity
J
Supply and install signage including all fittings, fixings, support, accessories and all in accordance with specifications and drawings
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - FURNISHINGS - Page No. 12.1
BILL NO. 03 - FURNISHINGS - Page No. 12.1
Code
Description
Note:
DIVISION 12 - FURNISHINGS
Note:
Loose Furnitures
Note:
Supply and install furniture including fittings, fixing, hardware, accessories and all related works, complete in accordance with drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. BD-01, Single Wooden Bedroom (1.00x2.20)m
No
12
B
Ref. BD-02, Clinic Bedroom (1.00x2.00)m
No
1
C
Ref. BT-01, Wooden Comod 400x400mm
No
12
D
Ref. CF-LCA-01, Base cabinet with laminate doors, solid-surface countertop, and drop-in sink
No
3
E
Ref. CF-UCA-01, Wall-mounted upper kitchen cabinet with hinged laminate doors
No
3
F
Ref. CH-01, Chair high back wooden leg
No
13
G
Ref. CH-02, Wooden office chair (0.65x0.65)m
No
6
H
Ref. CH-03, 5 Star base fully upholstered with arms
No
36
J
Ref. CH-04, Wooden Chair with high long back leg
No
17
K
Ref. CH-05, Wooden table for four chair
No
16
L
Ref. CH-06, Ergonomic swivel office chair with armrests and headset
No
12
M
Ref. CP-01, Carpet (4x3)m
No
3
N
Ref. DSK-01, Wooden office desk (1.75x0.75)m
No
14
P
Ref. DSK-02, Wooden office desk (2.5x0.75)m
No
3
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - FURNISHINGS - Page No. 12.2
BILL NO. 03 - FURNISHINGS - Page No. 12.2
Code
Description
Note:
DIVISION 12 - FURNISHINGS (Cont'd)
Note:
Loose Furnitures (Cont'd)
Note:
Supply and install furniture including fittings, fixing, hardware, accessories and all related works, complete in accordance with drawings and specifications. (Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. DT-01, Wooden table for six chair
No
3
B
Ref. DT-02, Wooden table for four chair
No
1
C
Ref. KC-01, Base cabinet unit with laminate doors, solid-surface countertop- and drop-in sink
No
1
D
Ref. MR-01, Bathroom Mirror
No
2
E
Ref. SF-01, Sofa for Reception area (2.40x1.00)m
No
3
F
Ref. SF-02, Sofa arm chair for Reception area (2.40x1.00)m
No
3
G
Ref. SF-03, Reception wooden table (1.00x0.55)m
No
1
H
Ref. TB-01, Wooden stand stable with glass
No
11
J
Ref. TB-02, Wooden bedroom table (1.50x.50)m
No
6
K
Ref. TB-03, Wooden stand stable with glass
No
3
L
Ref. TB-04, meeting room table for 6 person
No
2
M
Ref. TB-04, meeting room table for 6 person
No
5
N
Ref. TB-06, Wooden office for staff room
No
12
P
Ref. TB-07, Wooden office for staff room
No
3
Q
Ref. TV-01, TV Reception area
No
3
R
Ref. TV-TB-01, Reception counter (1.40x0.501)m
No
3
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - FURNISHINGS - Page No. 12.3
BILL NO. 03 - FURNISHINGS - Page No. 12.3
Code
Description
Note:
DIVISION 12 - FURNISHINGS (Cont'd)
Note:
Loose Furnitures (Cont'd)
Note:
Supply and install furniture including fittings, fixing, hardware, accessories and all related works, complete in accordance with drawings and specifications. (Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. WR-01, Deskdrawer for bedroom (2.30x0.55)m
No
6
B
Ref. WR-02, Deskdrawer for gem (4.00x0.55)m
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION - Page No. 15.1
BILL NO. 03 -MECH INSTALLATION - Page No. 15.1
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS
Note:
Rainwater, soil,  waste, and vent pipework installations complete in accordance with specifications and drawings
Note:
Pipework
Note:
Above ground uPVC pipework including fittings, accessories, insect screen, and all necessary works complete in accordance with drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
A
50mm diameter
m
16
B
82mm diameter
m
34
C
110mm diameter
m
88
Code
Description
Note:
Under ground uPVC pipework including excavation, backfilling, warning tap, fittings, accessories, and all necessary works complete in accordance with drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
D
50mm diameter
m
90
E
82mm diameter
m
25
F
110mm diameter
m
197
Code
Description
Note:
Fittings, complete in accordance with drawings and specifications
Note:
Rain Water Drain
Code
Description
Remarks
Unit of Measurement
Quantity
G
Ref. RWO, 110mm diameter
No
16
Code
Description
Note:
Floor Drain
Code
Description
Remarks
Unit of Measurement
Quantity
H
Ref. FD, 150x150mm
No
21
Code
Description
Note:
Floor Cleanout
Code
Description
Remarks
Unit of Measurement
Quantity
J
Ref. FCO 110mm diameter
No
28
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.2
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.2
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Vent Cowl
Code
Description
Remarks
Unit of Measurement
Quantity
A
Size 82mm
No
7
B
Size 110mm
No
3
Code
Description
Note:
Grating Cover
Code
Description
Remarks
Unit of Measurement
Quantity
C
Grating cover, size 1800x200mm
No
3
D
Grating cover, size 2000x500mm
No
2
E
Shower Grating, size 800x70mm
No
6
Code
Description
Note:
Domestic Hot and Cold Water Installation
Note:
Cold Water Supply System
Note:
Supply and install cold water PPR pipe works including necessary, fittings, valves and accessories, and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
F
20mm diameter
m
331
G
25mm diameter
m
21
H
32mm diameter
m
37
J
32mm diameter, circulation pipe
m
8
K
40mm diameter
m
8
L
40mm diameter, water transfer line
m
31
M
50mm diameter
m
44
N
65mm diameter
m
1
P
100mm diameter
m
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.3
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.3
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Domestic Hot and Cold Water Installation
Note:
Hot Water Supply System
Note:
Supply and install hot water PPR pipe works with insulation including necessary, fittings, valves and accessories, and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
20mm diameter
m
242
B
25mm diameter
m
113
C
32mm diameter
m
49
Code
Description
Note:
Pumps
Note:
Supply, install test and commission domestic water pumps set with control panels, valves, check valves, fittings, supports, flexible connections, electrical works, vibration isolation, electronic pressure controller, pressure gauges, protections and all required components and accessories as per drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
D
Domestic water booster pump set, flow 1.60 L/S, head 2.50 Bar, (1 Duty, 1 Standby).
No
2
E
Domestic water circulation pump set, flow 1.60 L/S, head 2.50 Bar, (1 Duty, 1 Standby).
No
2
Code
Description
Note:
Hot Water Pump
Code
Description
Remarks
Unit of Measurement
Quantity
F
Hot water return pump set, flow 1.60 L/S, head 2.50 Bar, (1 Duty, 1 Standby).
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.4
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.4
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Domestic Hot and Cold Water Installation (Cont'd)
Note:
Demotic Water Tank
Note:
GRP hot pressed panel type, sectional insulated water tank including connections, float valve, pipes, access panel, fitting, accessories  and valves and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Size 4.0 x 2.50 x 1.50 m, capacity 15.0 m3
No
1
Code
Description
Note:
Solar System
Note:
Supply, install, test and commission flat plate solar system. Including collectors, tanks, short pipes, vent, valves, complete with all fittings, supports and all required accessories as per drawings & specifications.
Code
Description
Remarks
Unit of Measurement
Quantity
B
Flat plate solar system, (3 Collectors)
No
1
Code
Description
Note:
Pressure Vessel
Code
Description
Remarks
Unit of Measurement
Quantity
C
Pressure vessel, capacity 100 L
No
1
Code
Description
Note:
UV Sterilization Unit
Note:
Supply, install test and commission UV Sterilization complete with  all required components and accessories as per drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
D
UV sterilization unit, 1.6 L/s
No
1
Code
Description
Note:
Domestic Cooler Unit
Note:
Supply, install test and commission domestic cooler unit complete with valves, fittings, supports, electrical works, and all required components and accessories as per drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
E
Cooler unit, cooling capacity 10.5 kw
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.5
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.5
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Domestic Hot and Cold Water Installation (Cont'd)
Note:
Estidama Water Meter
Note:
Supply and install estidama water meter including valves, fitting with all required accessories as per drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
A
Estidama water meter, ref EWM-01
No
1
B
Estidama water meter, ref EWM-02
No
1
Code
Description
Note:
Isolating Valves
Code
Description
Remarks
Unit of Measurement
Quantity
C
15mm diameter
No
4
D
20mm diameter
No
52
E
32mm diameter
No
5
F
40mm diameter
No
1
G
50mm diameter
No
3
H
50mm diameter (NC)
No
1
Code
Description
Note:
Bib Tap
Code
Description
Remarks
Unit of Measurement
Quantity
J
15mm diameter
No
4
K
20mm diameter
No
1
Code
Description
Note:
Ball Valves
Code
Description
Remarks
Unit of Measurement
Quantity
L
20mm diameter
No
15
Code
Description
Note:
Gate Valves
Code
Description
Remarks
Unit of Measurement
Quantity
M
25mm diameter
No
3
N
32mm diameter
No
3
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.6
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.6
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Domestic Hot and Cold Water Installation (Cont'd)
Note:
Water Hammer Arrestor
Code
Description
Remarks
Unit of Measurement
Quantity
A
20mm diameter
No
36
Code
Description
Note:
Fire Fighting System
Note:
Supply and install black  steel fire fighting water pipe works including drain pipes, fittings, accessories valve and supports and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
25mm diameter
m
454
C
25mm diameter, drain pipe
m
2
D
32mm diameter
m
30
E
40mm diameter
m
46
F
50mm diameter
m
31
G
65mm diameter
m
35
H
65mm diameter, wet riser pipe
m
24
J
80mm diameter
m
30
K
80mm diameter, wet riser pipe
m
9
L
100mm diameter
m
31
M
150mm diameter
m
20
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.7
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.7
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Fire Fighting System (Cont'd)
Note:
Fire Hose Cabinet
Note:
Supply, install, test and commission hose station consist of a 25 mm hose reel & a 65 mm diameter landing valve including but not limited to cabinets, reels, fire extinguishers, isolating valves, pressure regulating valves, pressure reducing valves hoses, nozzles, marking, fixings, supports and all required components and accessories as per drawings, specifications and civil defense regulations.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref FHC
No
2
Code
Description
Note:
Frie Extinguisher
Note:
Supply install test and commission fire extinguisher including but not limited to wall fixing frame and hanger and all required components and accessories as per drawings, specifications and civil defense regulations.
Code
Description
Remarks
Unit of Measurement
Quantity
B
5 Kg dry CO2 fire extinguisher
No
4
C
4.5 Kg dry powder fire extinguisher
No
2
D
FFP foam trolly type 33 gal.
No
1
Code
Description
Note:
Fire Blanket
Note:
Supply and fix fire blanket  including all accessories and all necessary works complete in  accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
E
Fire Blanket, ref FB
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.8
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.8
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Fire Fighting System (Cont'd)
Note:
Automatic Air Vent
Note:
Supply and install automatic air vent  including all accessories and all necessary works complete in  accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Automatic air vent, ref AAV, 150mm
No
1
Code
Description
Note:
Sprinkler Heads
Note:
Supply and install Sprinkler Heads including all fittings and  accessories complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Pendant sprinkler head
No
156
Code
Description
Note:
Valves and other fittings complete in accordance with specification and drawings
Note:
Zone Control Valve
Code
Description
Remarks
Unit of Measurement
Quantity
C
ZCV, 150mm
No
1
Code
Description
Note:
Pressure Reducing Valve
Code
Description
Remarks
Unit of Measurement
Quantity
D
PRV, 150mm
No
1
Code
Description
Note:
Non-Return Valve
Code
Description
Remarks
Unit of Measurement
Quantity
E
NRV, 150mm
No
1
Code
Description
Note:
Breeching Inlet
Code
Description
Remarks
Unit of Measurement
Quantity
F
150mm diaX 4 Way breeching inlet for sprinkler and wet riser systems
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.9
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.9
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation
Note:
Ductwork
Note:
Design, fabrication and installation of galvanized sheet metal ductwork including circular duct work, supports,  fittings and accessories, and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Supply duct
Kg
4,255
B
Return duct
Kg
579
C
Fresh duct
Kg
900
D
Exhaust duct
Kg
683
E
Toilet extract duct
Kg
771
F
Flexible supply air duct 200mm diameter
m
17
Code
Description
Note:
Internal Duct Insulation
Note:
Supply and install internal insulation for duct and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
G
For supply duct
m2
743
H
For return duct
m2
62
J
Toilet extract duct
m2
75
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.10
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.10
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation (Cont'd)
Note:
External Duct Insulation
Note:
Supply and install insulation for external duct with aluminum cladding and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Supply duct
m2
37
B
Return duct
m2
36
C
For fresh duct
m2
147
D
For exhaust duct
m2
123
E
Toilet extract duct
m2
89
Code
Description
Note:
Fresh Air Handling Units
Note:
Supply and install fresh air handling units including connections to the ducts, controls, anti vibration mountings, thermostat, smoke detectors, sensors,  filters, coil, protective devices and drain and all necessary works complete in accordance with  specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
F
FAHU-01 air flow rate 2700 L/s, cooling capacity 22.52 kw
No
1
Code
Description
Note:
Condensate Unit
Note:
Supply and install condensate unit including connections to the pipes, controls, anti vibration mountings, thermostat, smoke detectors, sensors,  filters, coil, protective devices and drain and all necessary works complete in accordance with  specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
G
CU/01-FAHU-01
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.11
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.11
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation(Cont'd)
Note:
Package Units
Note:
Supply, install, test and commission package unit, including but not limited to insulation, electrical and control wiring, cables, thermostats, control devices, supports, fittings, vibration isolation and all required components and accessories as per drawings, specifications and according to manufacturers requirements.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. GF-PU-01, flow rate 3505 L/s
No
1
B
Ref. GF-PU-02, flow rate 1830 L/s
No
1
C
Ref. GF-PU-03, flow rate 2275 L/s
No
1
D
Ref. GF-PU-04, flow rate 1516 L/s
No
1
E
Ref. GF-PU-05, flow rate 2275 L/s
No
1
Code
Description
Note:
Fans
Note:
Supply and install fans including connections, fittings, back draft, and accessories and all necessary works complete in accordance with  specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
F
Ref. 02-EXF-01, flow rate 57 L/s
No
3
Code
Description
Note:
Sound Attenuator
Code
Description
Remarks
Unit of Measurement
Quantity
G
Sound attenuator ref. SA, size 600x550mm
No
1
H
Ditto ref. SA, size 650x600mm
No
1
J
Ditto ref. SA, size 650x650mm
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.12
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.12
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation(Cont'd)
Note:
Sound Attenuator (Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ditto ref. SA, size 800x500mm
No
1
B
Ditto ref. SA, size 850x750mm
No
1
C
Ditto ref. SA, size 900x500mm
No
1
Code
Description
Note:
Variable & Constant Air Volume System
Note:
Supply and install VAV/CAV box including connections, fittings, and accessories and all necessary works complete in accordance with  specification and drawings
Note:
Variable Air Volume
Code
Description
Remarks
Unit of Measurement
Quantity
D
Ref. 01-VAV-01, flow rate 337 L/s
No
1
E
Ref. 01-VAV-02, flow rate 242 L/s
No
1
F
Ref. 01-VAV-03, flow rate 245 L/s
No
1
G
Ref. 01-VAV-04, flow rate 228 L/s
No
1
H
Ref. 01-VAV-05, flow rate 295 L/s
No
1
J
Ref. 01-VAV-06, flow rate 233 L/s
No
1
K
Ref. 01-VAV-07, flow rate 127 L/s
No
1
L
Ref. 01-VAV-08, flow rate 63 L/s
No
1
M
Ref. 01-VAV-09, flow rate 63 L/s
No
1
N
Ref. 01-VAV-10, flow rate 144 L/s
No
1
P
Ref. 01-VAV-11, flow rate 125 L/s
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.13
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.13
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation(Cont'd)
Note:
Variable & Constant Air Volume System (Cont'd)
Note:
Variable Air Volume (Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. 01-VAV-12, flow rate 837 L/s
No
1
B
Ref. 01-VAV-13, flow rate 319 L/s
No
1
C
Ref. 01-VAV-14, flow rate 195 L/s
No
1
D
Ref. 01-VAV-15, flow rate 195 L/s
No
1
E
Ref. 01-VAV-16, flow rate 195 L/s
No
1
F
Ref. 01-VAV-17, flow rate 414 L/s
No
1
G
Ref. 01-VAV-18, flow rate 249 L/s
No
1
H
Ref. 01-VAV-19, flow rate 60 L/s
No
1
J
Ref. 01-VAV-20, flow rate 158 L/s
No
1
K
Ref. 01-VAV-21, flow rate 517 L/s
No
1
L
Ref. 01-VAV-22, flow rate 202 L/s
No
1
M
Ref. 01-VAV-23, flow rate 225 L/s
No
1
N
Ref. 01-VAV-24, flow rate 125 L/s
No
1
P
Ref. 01-VAV-25, flow rate 219 L/s
No
1
Q
Ref. 01-VAV-26, flow rate 353 L/s
No
2
R
Ref. 01-VAV-27, flow rate 399 L/s
No
1
S
Ref. 01-VAV-28, flow rate 18 L/s
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.14
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.14
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation(Cont'd)
Note:
Variable & Constant Air Volume System (Cont'd)
Note:
Variable Air Volume (Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. 01-VAV-29, flow rate 65 L/s
No
1
B
Ref. 01-VAV-30, flow rate 91 L/s
No
1
C
Ref. 01-VAV-31, flow rate 397 L/s
No
1
D
Ref. 01-VAV-32, flow rate 267 L/s
No
1
E
Ref. 01-VAV-33, flow rate 267 L/s
No
1
F
Ref. 01-VAV-34, flow rate 267 L/s
No
1
G
Ref. 01-VAV-35, flow rate 287 L/s
No
1
H
Ref. 01-VAV-36, flow rate 477 L/s
No
1
J
Ref. 01-VAV-37, flow rate 95 L/s
No
1
K
Ref. 01-VAV-38, flow rate 65 L/s
No
1
Code
Description
Note:
Constant Air Volume
Code
Description
Remarks
Unit of Measurement
Quantity
M
Ref. 01-CAV-01, flow rate 132 L/s
No
1
N
Ref. 01-CAV-02, flow rate 250 L/s
No
1
P
Ref. 01-CAV-03, flow rate 188 L/s
No
1
Q
Ref. 01-CAV-04, flow rate 140 L/s
No
1
R
Ref. 01-CAV-05, flow rate 122 L/s
No
1
S
Ref. 01-CAV-06, flow rate 542 L/s
No
2
T
Ref. 01-CAV-07, flow rate 50 L/s
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.15
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.15
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation(Cont'd)
Note:
DX Unit
Note:
Supply, install, test and commission  DX unit cooling only including but not limited to indoor & outdoor units, vibration isolation, control wiring, flexible connectors, integral control, hanger, supports, filters, sleeves, condensate piping and all required accessories as per drawings and specifications.
Code
Description
Remarks
Unit of Measurement
Quantity
A
02-SP-01 / CU/02-SP-01, air side 133 L/s
No
1
Code
Description
Note:
Dampers
Note:
Supply and install damper including connections, fittings and accessories and all necessary works complete in accordance with specification and drawings
Note:
Volume Control Damper
Code
Description
Remarks
Unit of Measurement
Quantity
B
Volume control damper ref. VCD size 100X100mm
No
1
C
Ditto ref. VCD size 150X100mm
No
10
D
Ditto ref. VCD size 200x150mm
No
10
E
Ditto ref. VCD size 250x150mm
No
1
F
Ditto ref. VCD size 300x150mm
No
2
G
Ditto ref. VCD size 300x200mm
No
1
H
Ditto ref. VCD size 300x250mm
No
3
J
Ditto ref. VCD size 350x150mm
No
1
K
Ditto ref. VCD size 350x250mm
No
3
L
Ditto ref. VCD size 350x300mm
No
1
M
Ditto ref. VCD size 350x350mm
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.16
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.16
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Volume Control Damper (Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Volume control damper ref. VCD size 400x150mm
No
1
B
Ditto ref. VCD size 400x250mm
No
4
C
Ditto ref. VCD size 400x300mm
No
1
D
Ditto ref. VCD size 450x150mm
No
1
E
Ditto ref. VCD size 450x200mm
No
4
F
Ditto ref. VCD size 500x150mm
No
2
G
Ditto ref. VCD size 500x250mm
No
1
H
Ditto ref. VCD size 500x550mm
No
1
J
Ditto ref. VCD size 600x250mm
No
2
K
Ditto ref. VCD size 600x400mm
No
1
L
Ditto ref. VCD size 600x450mm
No
1
M
Ditto ref. VCD size 650x150mm
No
1
N
Ditto ref. VCD size 650x200mm
No
2
P
Ditto ref. VCD size 650x300mm
No
3
Q
Ditto ref. VCD size 650x650mm
No
6
R
Ditto ref. VCD size 750x300mm
No
1
S
Ditto ref. VCD size 850x700mm
No
1
T
Ditto ref. VCD size 200mm diameter
No
36
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.17
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.17
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Volume Control Damper (Cont'd)
Note:
Dampers (Cont'd)
Note:
Fire Damper
Code
Description
Remarks
Unit of Measurement
Quantity
A
Fire damper ref. FD, size 150x100mm
No
9
B
Ditto ref. FD, size 400x250mm
No
2
C
Ditto ref. FD, size 500x5500mm
No
1
D
Ditto ref. FD, size 650x300mm
No
2
E
Ditto ref. FD, size 650x650mm
No
3
F
Ditto ref. FD, size 850x700mm
No
1
Code
Description
Note:
Motorized Damper
Code
Description
Remarks
Unit of Measurement
Quantity
G
Motorized damper ref. MD, size35x350mm
No
1
H
Ditto ref. MD, size 400x300mm
No
1
J
Ditto ref. MD, size 400x350mm
No
1
K
Ditto ref. MD, size 400x350mm (NC)
No
1
L
Ditto ref. MD, size 550x400mm
No
3
M
Ditto ref. MD, size 600x250mm
No
1
N
Ditto ref. MD, size 650x300mm
No
1
P
Ditto ref. MD, size 650x400mm
No
1
Q
Ditto ref. MD, size 700x400
No
1
Code
Description
Note:
Non-Return Damper
Code
Description
Remarks
Unit of Measurement
Quantity
R
Ditto ref. NRD, size 150x100mm
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.18
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.18
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation(Cont'd)
Note:
Diffusers, Grills, Dampers, Liner diffusers
Note:
Supply and return air slot diffuser with integrated opposed blades volume damper and with adjustable deflection blades with 25mm thick acoustic one plenum box.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. SLD, 1000mm length, 1-slot
No
38
B
Ref. RLD, 1000mm length, 1-slot
No
38
Code
Description
Note:
Supply and return air diffuser
Code
Description
Remarks
Unit of Measurement
Quantity
C
Ref. SD 150x100mm
No
2
D
Ref. SD 150x150mm
No
6
E
Ref. SD 225x225mm
No
17
F
Ref. SD 300x300mm
No
23
G
Ref. SD 375x375mm
No
20
H
Ref. RD 150x100mm
No
2
J
Ref. RD 150x150mm
No
6
K
Ref. RD 225x225mm
No
17
L
Ref. RD 300x300mm
No
23
M
Ref. RD 375x375mm
No
19
Code
Description
Note:
Disk Valve
Code
Description
Remarks
Unit of Measurement
Quantity
N
Ref. DV 150mm diameter
No
18
Code
Description
Note:
Exhaust Diffuser
Code
Description
Remarks
Unit of Measurement
Quantity
P
Ref. EAD 150x150mm
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.19
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.19
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation(Cont'd)
Note:
Diffusers, Grills, Dampers, Liner diffusers(Cont'd)
Note:
Round supply and return air diffuser with adjustable butter fly control dampers(CONT'D)
Note:
Supply Grille
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. SG 100x100mm
No
1
B
Ref. SG 300x300mm
No
1
C
Ref. SG 350x150mm
No
1
D
Ref. SG 500x200mm
No
2
Code
Description
Note:
Return Grille
Code
Description
Remarks
Unit of Measurement
Quantity
E
Ref. RG 100x100mm
No
1
F
Ref. RG 300x300mm
No
1
G
Ref. RG 350x150mm
No
1
H
Ref. RG 500x200mm
No
2
Code
Description
Note:
Exhaust Air Louver
Code
Description
Remarks
Unit of Measurement
Quantity
J
EAL, with bird screen, 2700 L/s, face area 1.35m2
No
1
K
EAL, with bird screen, 570 L/s, face area 0.50m2
No
1
Code
Description
Note:
Fresh Air Louver
Code
Description
Remarks
Unit of Measurement
Quantity
L
FAL, with sand trap and insect screen, 2195 L/s, face area 1.95m2
No
1
Code
Description
Note:
Building Management System (BMS)
Code
Description
Remarks
Unit of Measurement
Quantity
M
Supply, install, test and commissioning  of Building management system including points, wires, conduits, and  all necessary works complete in accordance with specifications and drawings
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.20
BILL NO. 03 -MECH INSTALLATION (Cont'd) - Page No. 15.20
Code
Description
Note:
Sundry / General Items
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for permits, connection and inspection fees associated with mechanical installations by utility and statutory authorities
Item
1
B
Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings
Item
1
C
Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment
Item
1
D
Allow for setting out the works, marking positions of holes, mortises, chases or the like
Item
1
E
Allow for testing and commissioning and submission of test certificates
Item
1
F
Allow for all identification labels, plates, charts and identification of plant, equipment, cable, isolators and the like
Item
1
G
Allow for preparing schedule of manufacturers recommended tools and spare parts for each piece of equipment
Item
1
H
Allow for the provision of operating/maintenance manuals
Item
1
J
Allow for providing shop and coordination drawings
Item
1
K
Allow for domestic water piping, sterilization and disinfections after commissioning
Item
1
L
Allow for flushing chilled water system pipe work  with water and establishment of rust inhibitor before commissioning
Item
1
M
Allow for fire stopping in accordance with the drawings, specification and local authorities requirements
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS
Note:
Power System installations
Note:
Automatic Transfer Switch (ATS)
Note:
Supply and  install automatic transfer switch including fixing, fittings, terminations, accessories and all necessary works  complete in accordance  with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
ATS 63A
No
1
Code
Description
Note:
Generator
Note:
Supply, install, test, commission and maintain, prime rated  generator including, but not limited to, lubrication system, control panels, fuel system and all associated devices and equipment, earthing, and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Standby diesel generator 18KW/22KVA
No
1
Code
Description
Note:
Main &Sub Main Distribution Boards
Note:
Supply, install, test, commission, and maintain main and sub-main distribution boards and terminations, including bus bars, breakers, indicators,  meters, all interconnecting cables, wires termination, energy monitoring meters, and trays from the main board,  and all necessary works complete in accordance with specification and drawings
Note:
Main Distribution Boards
Code
Description
Remarks
Unit of Measurement
Quantity
C
Main distribution boards, ref MDB-PD
No
1
D
Ditto, ref MDB-PD-AC
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Power System Installations (Cont'd)
Note:
Main &Sub Main Distribution Boards (Cont'd)
Note:
Supply, install, test, commission, and maintain main and sub-main distribution boards and terminations, including bus bars, breakers, indicators,  meters, all interconnecting cables, wires termination, energy monitoring meters, and trays from the main board,  and all necessary works complete in accordance with specification and drawings
Note:
Sub Main Distribution Boards
Code
Description
Remarks
Unit of Measurement
Quantity
A
Sub main distribution boards, ref ESMDB-PD
No
1
Code
Description
Note:
Final Distribution Boards
Note:
Supply, install, test, commission and maintain Final Distribution boards and terminations including bus bars, breakers, indicators, all interconnecting cables, wires termination and trays from main board,  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Final distribution boards, DB-P4
No
1
C
Ditto, ref DB-P5
No
1
D
Ditto, ref DB-P6
No
1
E
Ditto, ref DB-L2
No
1
F
Ditto, ref EDB-L2
No
1
G
Lighting control panel, ref LCP
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Cable Tray
Note:
Supply and  install Cable trunk including fixing, fittings, accessories and all necessary works  complete in accordance  with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
200x100mm cable trunk
m
888
B
100x50mm cable trunk with cover
m
29
C
400x100mm cable trunk with cover
m
55
D
600x100mm cable trunk with cover
m
60
Code
Description
Note:
Cables
Note:
Low Voltage cables including ducts, glands, connections, conduits, termination, trays  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
E
2C.6 mm2 XLPE/SWA/PVC  +1C.6 mm2 PVC/ECC/CU
m
282
F
2C.6 mm2 fire rated XLPE/SWA/PVC  +1C.6 mm2 fire rated PVC/ECC/CU
m
95
G
4C.10 mm2 XLPE/SWA/PVC  +1C.10 mm2 PVC/ECC/CU
m
361
H
4C.10 mm2 fire rated XLPE/SWA/PVC  +1C.10 mm2 fire rated PVC/ECC/CU
m
58
J
4C.16mm2 XLPE/SWA/PVC  +1C.16 mm2 PVC/ECC/CU
m
89
K
4C.25mm2 XLPE/SWA/PVC  +1C.16 mm2 PVC/ECC/CU
m
179
L
4C.25 mm2 fire rated XLPE/SWA/PVC  +1C.16 mm2 fire rated PVC/ECC/CU
m
17
M
4C.35mm2 XLPE/SWA/PVC  +1C.16 mm2 PVC/ECC/CU
m
47
N
4C.50mm2 XLPE/SWA/PVC  +1C.25 mm2 PVC/ECC/CU
m
12
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Power Distribution
Note:
Supply and install the following power fittings including all necessary accessories and connections to wiring  and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
13A Single switched socket
No
67
B
13A Twin switched socket
No
63
C
13A switched socket inside floor box
No
64
D
15A Switched socket
No
4
E
13A Switched spur outlet
No
48
F
13A Unswitched spur outlet
No
3
Code
Description
Note:
Power point
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trucking, access box with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
G
Power points
No
249
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Power System Installations (Cont'd)
Note:
Floor Boxes
Note:
Supply, and install, floor boxes, including fixing, fitting, with all necessary works complete all in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Floor box with two compartments
No
32
Code
Description
Note:
Isolating Switch
Note:
Supply and install isolating switch  including all interconnecting and terminations  and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Isolator single phase 32A
No
2
C
Isolator single phase 32A IP65
No
5
D
Isolator three phase 32A IP65
No
4
E
Isolator three phase 40A
No
1
F
Isolator three phase 40A IP65
No
1
G
Isolator three phase 63A IP65
No
4
H
Isolator three phase 80A IP65
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Power System Installations (Cont'd)
Note:
Internal Lighting
Note:
Supply and install lighting including all necessary accessories  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Lighting fixture,  type S1
No
26
B
Ditto,  type S2
No
32
C
Ditto,  type S3
No
17
D
Ditto,  type S4
No
134
E
Ditto,  type S5
No
30
F
Ditto,  type S6
No
33
G
Ditto,  type S7
No
12
H
Ditto,  type W1
No
9
J
Ditto,  type L1
No
15
Code
Description
Note:
Internal Lighting Points
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
K
Internal Lighting points
No
308
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.7
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.7
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Power System Installations (Cont'd)
Note:
Switches
Note:
Supply, install, test, commission switches including all necessary accessories  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
One gang, one way lighting switch 20A
No
4
B
One gang, one way lighting switch 20A, W/P
No
3
C
Two gang, one way lighting switch 20A
No
11
D
Three gang, two way lighting switch 20A
No
12
E
Two gang, one way override switch 20A
No
32
F
Three gang, one way override switch 20A
No
2
G
Two gang, two way override switch 20A
No
4
H
Lux and absence multi sensor
No
13
J
Presence sensor
No
31
K
Motion sensor
No
21
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.8
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.8
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Power System Installations (Cont'd)
Note:
Switches (Cont'd)
Note:
Supply, install, test, commission switches including all necessary accessories  and all necessary works complete in accordance with specifications and drawings
Note:
Lighting switch Point
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Lighting switch points
No
68
B
Sensors points
No
65
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.9
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.9
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Emergency and Exit Lighting System
Note:
Supply, install, test, commission  the following emergency and exit light fittings, including  ceiling rose, heat resistance, flexible cable, lamps, electronic control gear, suspensions, connections to permanent wiring system in accordance with Specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Self-contained 1x8w emergency light with built-in battery (3h duration ), surface-mounted, non-maintained
No
5
B
Self-contained 1x8w emergency light with built-in battery (3h duration ), recessed mounted, non-maintained
No
46
C
Self-contained 1x8w  exit light maintained with a built-in battery (3h duration )
No
13
D
Self-contained 1x8w  exit light double-sided, maintained with a built-in battery (3h duration )
No
1
Code
Description
Note:
Emergency lighting points
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trunking, with all accessories,  and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
E
Emergency lighting points
No
65
Code
Description
Note:
Central Battery System
Note:
Supply and install central battery system including , pull boxes, junction boxes, wires,  and connections to relevant panel complete as shown on drawings and as per specifications
Code
Description
Remarks
Unit of Measurement
Quantity
F
Emergency light monitoring panel, ref EMP-POD
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.10
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.10
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Fire Alarm System
Note:
Supply, install, test, commission and maintain  the complete Analogue addressable fire Alarm & evacuation system including cabling, wiring conduit, cable tray, trunking, termination and power connections  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Intelligent optical smoke detector and standard base
No
56
B
Smoke detector above ceiling void area
No
57
C
Intelligent heat detector with standard base
No
2
D
Intelligent optical smoke detector with sounder base
No
6
E
Manual call point
No
6
F
Fire alarm sounder with flasher
No
4
G
Fire alarm sounder or horn, W/P
No
4
H
Voice evacuation, ceiling mounted speaker
No
24
J
Desk type microphone for emergency voice broadcast
No
5
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.11
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.11
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Fire Alarm System (Cont'd)
Note:
Disabled Alarm System
Note:
Supply, install, test, commission and maintain  the complete Analogue addressable Disabled Alarm System including cabling, wiring conduit, cable tray, trunking, termination and power connections  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Reset point
No
2
B
Over light door & sounder unit above the door with WC sticker
No
2
C
Disabled toilet alarm pull cord
No
2
D
standalone alarm controller & power supply
No
2
Code
Description
Note:
Supply, install, test, commission fire alarm control panel with charger and batteries, power supply, fire fighter two way communication, amplifiers, voice evac., alarm system, AUX. output, PC monitor and control, software, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
E
Fire alarm and voice evacuation integrated control panel, ref FACP-POD, two loops
No
1
F
24/7 DCD monitoring panel
No
1
G
Voice evacuation control system, VECP-POD
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.12
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.12
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Telecommunication System
Note:
Supply, install, test, commission  complete telecommunication system,  including cabling, wiring, conduits, cables, terminations and power connections  and all necessary works complete all in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Single data outlet (RJ45) above ceiling
No
1
B
Voice outlet (RJ45) wall mounted
No
15
C
Data outlet for wireless access point outlet ceiling based
No
11
D
Single data outlet (RJ45) wall mounted for IPTV
No
11
E
Dual (RJ45) data&voice socket outlet wall mounted
No
26
F
Data outlet inside floor box
No
32
G
Telephone outlet inside floor box
No
32
Code
Description
Note:
Communications Equipment
Note:
Supply and install of data and communication equipment and racks; including all kinds of cable, wires, cable trays,  and all required components, internal connections, all necessary support, fixings and accessories;  and all necessary works complete all in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
H
42U telephone rack
No
1
J
Proposed server rack at main server room
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.13
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.13
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
CCTV System
Note:
Supply install, test and commission complete CCTV system including rack, monitors, controllers , cabling, wiring, conduit and power connections, and all necessary works complete all in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
IP based identification dome camera
No
6
B
IP based recognition dome camera
No
20
C
IP based wall mounted weather proof bullet camera detection level
No
13
D
Future IP dome camera containment includes conduit and CAT6A cable
No
20
E
Provision for camera
No
14
Code
Description
Note:
CCTV Work Station
Note:
Supply and install CCTV works station, including, computer, screens, printers, and all necessary works complete all in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
F
CCTV work stations
No
2
Code
Description
Note:
Security Equipment
Note:
Supply and install of data and security equipment and racks; including all kinds of cable, wires, cable trays,  and all required components, internal connections, all necessary support, fixings and accessories;  and all necessary works complete all in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
G
Security rack 24U, ref MDF-SC-POD
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.14
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.14
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Access Control System
Note:
Supply install, test and commission complete access control system including cabling, cable tray, wiring, conduit and power connections, and all necessary works complete all in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Master door control panel
No
1
B
Door control panel
No
7
C
Door contact
No
27
D
Electric mortise lock
No
12
E
Electro magnetic lock
No
15
F
Card reader
No
18
G
Exit push button
No
18
H
Break glass unit
No
18
Code
Description
Note:
Cable Tray
Note:
Supply and  install Cable trays including fixing, fittings, accessories and all necessary works  complete in accordance  with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
J
150x50mm HDGI cable tray for GSM
m
131
K
200x50mm HDGI cable tray for ICT
m
131
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.15
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.15
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Earthing protection system
Note:
Supply, install, test and commissioning of earthing protection system including earth pits, conductors, bars ,bonds and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Earthing protection
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.16
BILL NO. 03 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.16
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Sundry / General Items
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for permits, connection and inspection fees associated with electrical installations by utility and statutory authorities
Item
1
B
Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings
Item
1
C
Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment
Item
1
D
Allow for setting out the works, marking positions of holes, mortises, chases or the like
Item
1
E
Allow for testing and commissioning and production of test certificates
Item
1
F
Allow for all identification labels, plates, charts and identification of plant, equipment, cable, switches and the like
Item
1
G
Allow for the provision of operating / maintenance manuals
Item
1
H
Allow for providing shop and coordination drawings
Item
1
J
Allow for instructing selected employer's personnel on all aspects of the operation of systems and equipment
Item
1
K
Supply and handover to the client all tools and equipment in accordance with the specification
Item
1
L
Allow for fire stopping in accordance with the drawings specification and local authorities requirements
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - SITE WORK - Page No. 2.1
BILL NO. 04 - SITE WORK - Page No. 2.1
Code
Description
Note:
DIVISION 02 - SITE WORKS
Note:
Site Preparation
Code
Description
Remarks
Unit of Measurement
Quantity
A
Site Clearance, including removal of rubbish, debris, vegetation, within the designated work area complete accordance with the specifications and drawings
m2
25
Code
Description
Note:
Excavation
Note:
Excavation from existing level to bottom of foundation levels complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Bulk Excavation
m3
6
C
Pit Excavation
m3
16
D
Trench Excavation
m3
2
Code
Description
Note:
Backfilling
Code
Description
Remarks
Unit of Measurement
Quantity
E
Backfilling, including compaction in layer complete in accordance with specifications and drawings
m3
10
Code
Description
Note:
Disposal of Material Arising From Excavations
Code
Description
Remarks
Unit of Measurement
Quantity
F
Remove surplus excavated material from site to approved location complete in accordance with specifications and drawings
m3
14
Code
Description
Note:
Road base
Code
Description
Remarks
Unit of Measurement
Quantity
G
Road base, including compaction in layer complete in accordance with specifications and drawings
m3
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - SITE WORK (CONT'D) - Page No. 2.2
BILL NO. 04 - SITE WORK (CONT'D) - Page No. 2.2
Code
Description
Note:
DIVISION 02 - SITE WORKS(CONT'D)
Note:
Anti - Termite Treatment
Note:
Allow for anti termite treatment under blinding and around building complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Laid horizontally
m2
25
B
Laid vertically
m2
55
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - CONCRETE WORK - Page No. 3.1
BILL NO. 04 - CONCRETE WORK - Page No. 3.1
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS
Note:
IN ACCORDANCE WITH SPECIFICATIONS AND DRAWINGS
Note:
Sub Structure
Note:
Plain concrete, C20/25 compressive strength with ordinary Portland cement, GGBS,  including shuttering,  additives, plasticizers, curing, vibrating,  and all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
100 mm thick Blinding
m3
4
Code
Description
Note:
Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating,   and all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Foundation
m3
3
C
Neck column
m3
1
D
Slab on grade
m3
3
E
Ground beam
m3
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - CONCRETE WORKS (Cont'd)- Page No. 3.2
BILL NO. 04 - CONCRETE WORKS (Cont'd)- Page No. 3.2
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS ( CONT`D)
Note:
Sub Structure (Cont`d)
Note:
Steel reinforcement
Note:
High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420  N/mm2 for shear design  complete in accordance with specification and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
A
10 mm diameter
kg
253
B
12 mm diameter
kg
145
C
16 mm diameter
kg
427
Code
Description
Note:
Shuttering
Note:
Temporary shuttering, standard finish complete in accordance with specifications and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
D
To sides of foundation
m2
9
E
To sides of neck columns
m2
7
F
To sides of ground beams
m2
18
Code
Description
Note:
Super Structure
Note:
Reinforced concrete, C45 fc' =36Mpa at 28 days cylinder compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating,   and all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
G
Columns
m3
2
H
Slabs
m3
3
J
Beams
m3
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - CONCRETE WORKS (Cont'd)- Page No. 3.3
BILL NO. 04 - CONCRETE WORKS (Cont'd)- Page No. 3.3
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS ( CONT`D)
Note:
Super Structure (Cont'd)
Note:
Steel reinforcement
Note:
High grade steel deformed bar reinforcement 460 Mpa according to BS 4449 complete in accordance with specification and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
A
10 mm diameter
kg
225
B
12 mm diameter
kg
615
C
16 mm diameter
kg
397
Code
Description
Note:
Shuttering
Note:
Temporary shuttering, standard finish complete in accordance with specifications and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
D
To sides of columns
m2
21
E
To sides and soffits of slabs
m2
47
F
To sides and soffits of beams
m2
17
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - CONCRETE WORKS (Cont'd)- Page No. 3.5
BILL NO. 04 - CONCRETE WORKS (Cont'd)- Page No. 3.5
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS ( CONT`D)
Note:
CONCRETE SUNDRIES
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for all joints including isolation, control, construction and contraction  joints or the like as required all in accordance with the specifications and drawings
Item
1
B
Allow for equipment base concrete as required all in accordance with the specifications and drawings
Item
1
C
Allow for structural opening for MEP services and networks throw slabs, beams, columns and foundations all in accordance with the specifications and drawings
Item
1
D
Allow for all builders work in connection with the whole of MEP works including all manholes, sumps, pits, etc.
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - MASONARY WORKS - Page No. 4.1
BILL NO. 04 - MASONARY WORKS - Page No. 4.1
Code
Description
Note:
DIVISION 04 - MASONRY WORKS
Note:
External Block Work
Note:
External concrete block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref.W-05, 200mm thick
m2
50
B
Ref.W-04, 300mm thick
m2
26
Code
Description
Note:
Internal Block Work
Note:
Internal concrete block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Ref.W-06, 100mm thick
m2
9
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - MASONARY WORKS - Page No. 4.2
BILL NO. 04 - MASONARY WORKS - Page No. 4.2
Code
Description
Note:
DIVISION 04 - MASONRY WORKS (CONT`D)
Note:
Masonry Sundries
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for control joint complete in accordance with specification and drawing
Item
1
B
Allow for fire sealant complete in accordance with specification and drawing
Item
1
C
Allow for all opening and builder works for all MEP services in connection with masonry works all complete in accordance with specification and drawing
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - METAL WORK - Page No. 5.1
BILL NO. 04 - METAL WORK - Page No. 5.1
Code
Description
Note:
DIVISION 05 - METAL WORKS
Note:
Non Structural Metal Work
Note:
Aluminium Powder Coated Canopy
Note:
Supply and install Aluminium powder coated canopy, including  steel box, galvanized beams supportive system, finishes, all fittings, accessories and fixings complete in accordance with specifications and drawings (Design by specialist)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Aluminium Canopy, L shaped  size 8200x1325mm
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - THERMAL & MOISTURE PROTECTION - Page No. 7.1
BILL NO. 04 - THERMAL & MOISTURE PROTECTION - Page No. 7.1
Code
Description
Note:
DIVISION 07 - THERMAL & MOISTURE PROTECTION
Note:
Substructure Waterproofing
Note:
Supply and apply 1000guage polyethylene separation sheet, complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Laid horizontally, under slab on grade
m2
20
Code
Description
Note:
Supply and apply 1 layer of 4mm THK. each waterproofing membrane torch applied, complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Laid horizontally, under and above foundation
m2
14
C
Laid horizontally, under ground beam
m2
5
D
Laid vertically, side foundation
m2
9
E
Laid vertically, column neck
m2
7
F
Laid vertically, side ground beam
m2
18
Code
Description
Note:
Protection
Note:
Supply and install seal tight protection board complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
G
Laid vertically & horizontally, 6mm thick
m2
41
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - THERMAL & MOISTURE PROTECTION - Page No. 7.2
BILL NO. 04 - THERMAL & MOISTURE PROTECTION - Page No. 7.2
Code
Description
Note:
DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D)
Note:
Roof Waterproofing System
Note:
Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings
Note:
Laid Horizontally
Code
Description
Remarks
Unit of Measurement
Quantity
A
Roof cement tiles, Size 300x300
m2
12
B
Polyflex combo-top coat (1000 mic thick), sri > 78 as per green building regulation
m2
12
C
SBR bonding agent
m2
12
D
Concrete screed (26n/mm 2-350opc, 80mm ave. thickness)
m2
12
E
Polyfab filter membrane (  1200mic thick)
m2
12
F
Polytex liquid U.V. protection coat ( 600mic thick)
m2
12
G
Polyurethane foam of thickness 110mm with  45-50kg/m  3density
m2
12
H
Light weight foam concrete, 50mm mni thickness. sloped to drain 2%
m2
12
J
Polybond bonding agent
m2
12
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - THERMAL & MOISTURE PROTECTION - Page No. 7.3
BILL NO. 04 - THERMAL & MOISTURE PROTECTION - Page No. 7.3
Code
Description
Note:
DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT`D)
Note:
Roof Waterproofing System ( Cont`d)
Note:
Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings (Cont`d)
Note:
Laid Vertically
Code
Description
Remarks
Unit of Measurement
Quantity
A
Brush applied polytex -hr top coat ( 1000mic thick) sri > 78
m
14
B
Fabric reinforcement
m
14
C
Angle Fillet, 100x100mm
m
14
D
Polybond bonding agent
m
14
E
polyfab filter membrane (1200mic thick)
m
14
F
Polyurethane foam of thickness 110mm with  45-50kg/m  3density
m
14
G
Aluminum flashing
m
14
Code
Description
Note:
Sundries
Code
Description
Remarks
Unit of Measurement
Quantity
H
Allow for waterproofing dressing around rain water outlet
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - DOORS & WINDOWS - Page No. 8.1
BILL NO. 04 - DOORS & WINDOWS - Page No. 8.1
Code
Description
Note:
DIVISION 08 - DOORS AND WINDOWS
Note:
External Doors
Note:
Wooden Doors
Note:
Supply and install wooden doors including solid wood frame with plastic laminated finish, ironmongeries, architrave, decorations, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref.WD-05, single leaf door, size 1250 x 2200mm
No
1
Code
Description
Note:
Aluminium Gate
Note:
Supply and install aluminium gate with powder coated finish  included finish, frame, ironmongeries, decorations, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref. MD-01, size 7200 x 2800mm high, Sliding
No
1
C
Ref. MD-02, size 1250 x 2800mm high
No
1
Code
Description
Note:
Aluminum Windows
Note:
Supply and install glazing aluminum windows with powder coated finish  including, sub-frame, ironmongeries, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
D
Ref-WN01, Size 2400 x 1200 mm
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - DOORS & WINDOWS - Page No. 8.2
BILL NO. 04 - DOORS & WINDOWS - Page No. 8.2
Code
Description
Note:
DIVISION 08 - DOORS AND WINDOWS
Note:
Internal Doors
Note:
Wooden Doors
Note:
Supply and install wooden doors including solid wood frame with plastic laminated finish, ironmongeries, architrave, decorations, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref.WD-08, single leaf door, size 1250 x 2200mm
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - FINISHES  - Page No. 9.1
BILL NO. 04 - FINISHES  - Page No. 9.1
Code
Description
Note:
DIVISION 09 - FINISHES
Note:
Internal Finishes
Note:
Backgrounds
Note:
Floor Screed
Note:
Supply and install Cement and sand screed with self levelling compound; including sand filling, surface preparation, and all necessary works; complete all in according to drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
A
To receive porcelain tiles
m2
16
Code
Description
Note:
Plaster
Note:
Supply and install 20mm thick cement and sand plaster to block or concrete walls and columns including metal lath and all necessary works complete  in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
To receive wall paint
m2
47
C
To receive wall tile
m2
19
Code
Description
Note:
Supply and install cement sand plaster to soffits including all necessary works complete  in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
D
To receive paint finish
m2
15
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - FINISHES  - Page No. 9.2
BILL NO. 04 - FINISHES  - Page No. 9.2
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
Internal Finishes
Note:
Supply and install porcelain tiles flooring including bedding materials, matching colored grout, polished, jointing  floor transition strips and acoustic underlay (where required) and all necessary works complete in accordance with specifications and drawings  (Screed measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref-FF01, porcelain tiles, Size 600x600mm
m2
13
Code
Description
Note:
Supply and install Unglazed non skid Porcelain tiles flooring including bedding materials, matching colored grout, polished, jointing  floor transition strips and acoustic underlay (where required) and all necessary works complete in accordance with specifications and drawings  (Screed measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref-FF02, porcelain tiles, Size 300x300mm
m2
3
Code
Description
Note:
Threshold
Note:
Supply and install  marble threshold including  bedding materials, waterproofing, grouting, jointing and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
200mm wide, 30mm thick
m
1
D
300mm wide, 30mm thick
m
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - FINISHES  - Page No. 9.3
BILL NO. 04 - FINISHES  - Page No. 9.3
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
Internal Finishes (Cont'd)
Note:
Skirting
Note:
Supply and install porcelain tile skirting including backing, jointing and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref-Sk01,  high heavy duty porcelain tiles  skirting, 100mm
m
16
Code
Description
Note:
Walls Finishes
Note:
Supply and install porcelain wall tiling fixed with approved adhesive including backing, jointing, corner trim  and all necessary works complete in accordance with specifications and drawings (Plaster measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref-WF-02, porcelain tiles, Size 300 x 600mm
m2
19
Code
Description
Note:
Painting and Decoration
Note:
Supply and install emulation high quality 100 % pure anti fungal & anti microbial (bacteria) highly washable paint , Matt finish, including backing, jointing, corner trim  and all necessary works complete in accordance with specifications and drawings (Plaster measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
C
Ref-WF-01, Emulation paint
m2
47
Code
Description
Note:
Supply and install emulation  paint over including  all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
D
Ref-CL-03
m2
15
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - FINISHES  - Page No. 9.4
BILL NO. 04 - FINISHES  - Page No. 9.4
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
External Finishes
Note:
Backgrounds
Note:
Plaster
Note:
Supply and install cement and sand plaster to block or concrete walls and columns including metal lath and all necessary works complete  in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
To external block or concrete walls and columns, to receive paint finish
m2
146
Code
Description
Note:
Painting and Decoration
Note:
Supply and apply paint finish including surface preparation,  primer coat, final coat and all necessary works complete in accordance with specifications  and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
To plastered walls, Ref. EF 01
m2
146
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - ACCESSORIES  - Page No. 10.1
BILL NO. 04 - ACCESSORIES  - Page No. 10.1
Code
Description
Note:
DIVISION 10 - ACCESSORIES
Note:
Sanitary Fixture & Accessories
Note:
Supply and install sanitary fixtures and accessories including fittings, fixings, connections and all necessary works complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. TB-009, Wall mounted soap dispenser
No.
1
B
Ref. FC-001
No.
1
C
Ref. LAV-003
No.
1
D
Ref. WC-003, Wall mounted water closet
No.
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 -MECH INSTALLATION - Page No. 15.1
BILL NO. 04 -MECH INSTALLATION - Page No. 15.1
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS
Note:
Rainwater, soil,  waste, and vent pipework installations complete in accordance with specifications and drawings
Note:
Pipework
Note:
Above ground uPVC pipework including fittings, accessories, insect screen, and all necessary works complete in accordance with drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
A
50mm diameter
m
1
B
82mm diameter
m
4
C
110mm diameter
m
1
Code
Description
Note:
Under ground uPVC pipework including excavation, backfilling, warning tap, fittings, accessories, and all necessary works complete in accordance with drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
D
50mm diameter
m
3
E
82mm diameter
m
1
F
110mm diameter
m
2
Code
Description
Note:
Fittings, complete in accordance with drawings and specifications
Note:
Rain Water Drain
Code
Description
Remarks
Unit of Measurement
Quantity
G
Ref. RWO, 110mm diameter
No
1
Code
Description
Note:
Floor Drain
Code
Description
Remarks
Unit of Measurement
Quantity
H
Ref. FD, 150x150mm
No
1
Code
Description
Note:
Floor Cleanout
Code
Description
Remarks
Unit of Measurement
Quantity
J
Ref. FCO 110mm diameter
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 -MECH INSTALLATION (Cont'd) - Page No. 15.2
BILL NO. 04 -MECH INSTALLATION (Cont'd) - Page No. 15.2
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Fittings, complete in accordance with drawings and specifications (Cont'd)
Note:
Vent Cowl
Code
Description
Remarks
Unit of Measurement
Quantity
A
Size 82mm
No
1
B
Size 110mm
No
1
Code
Description
Note:
Domestic Hot and Cold Water Installation
Note:
Cold Water Supply System
Note:
Supply and install cold water PPR pipe works including necessary, fittings, valves and accessories, and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
20mm diameter
m
23
Code
Description
Note:
Hot Water Supply System
Note:
Supply and install hot water PPR pipe works with insulation including necessary, fittings, valves and accessories, and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
D
20mm diameter
m
3
Code
Description
Note:
Isolating Valves
Code
Description
Remarks
Unit of Measurement
Quantity
E
20mm diameter
No
2
Code
Description
Note:
Water Hammer Arrestor
Code
Description
Remarks
Unit of Measurement
Quantity
F
20mm diameter
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 -MECH INSTALLATION (Cont'd) - Page No. 15.3
BILL NO. 04 -MECH INSTALLATION (Cont'd) - Page No. 15.3
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Domestic Hot and Cold Water Installation (Cont'd)
Note:
Electrical Water Heater
Note:
Supply, install, test and commission electrical water heater complete including all fittings and  accessories complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. EWH 30l liters
No
1
Code
Description
Note:
Fire Fighting System
Note:
Fire Extinguisher
Note:
Supply install test and commission fire extinguisher including but not limited to wall fixing frame and hanger and all required components and accessories as per drawings, specifications and civil defense regulations.
Code
Description
Remarks
Unit of Measurement
Quantity
B
5 Kg dry CO2 fire extinguisher
No
1
Code
Description
Note:
Air Conditioning System and Ventilation Installation
Note:
Ductwork
Note:
Design, fabrication and installation of galvanized sheet metal ductwork including circular duct work, supports,  fittings and accessories, and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Supply duct
Kg
25
Code
Description
Note:
Internal Duct Insulation
Note:
Supply and install internal insulation for duct and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
D
For supply duct
m2
4
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 -MECH INSTALLATION (Cont'd) - Page No. 15.4
BILL NO. 04 -MECH INSTALLATION (Cont'd) - Page No. 15.4
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Air Conditioning System and Ventilation Installation (Cont'd)
Note:
DX Unit
Note:
Supply, install, test and commission  DX unit cooling only including but not limited to indoor & outdoor units, vibration isolation, control wiring, flexible connectors, integral control, hanger, supports, filters, sleeves, condensate piping and all required accessories as per drawings and specifications.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. 03-FCU-01 / CU/03-FCU-01, air side 224 L/s
No
1
Code
Description
Note:
Diffusers, Grills, Dampers, Liner diffusers
Note:
Supply and return air diffuser
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref. SD 375x375mm
No
1
C
Ref. RD 375x375mm
No
1
Code
Description
Note:
Building Management System (BMS)
Code
Description
Remarks
Unit of Measurement
Quantity
D
Supply, install, test and commissioning  of Building management system including points, wires, conduits, and  all necessary works complete in accordance with specifications and drawings
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 -MECH INSTALLATION (Cont'd) - Page No. 15.5
BILL NO. 04 -MECH INSTALLATION (Cont'd) - Page No. 15.5
Code
Description
Note:
Sundry / General Items
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for permits, connection and inspection fees associated with mechanical installations by utility and statutory authorities
Item
1
B
Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings
Item
1
C
Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment
Item
1
D
Allow for setting out the works, marking positions of holes, mortises, chases or the like
Item
1
E
Allow for testing and commissioning and submission of test certificates
Item
1
F
Allow for all identification labels, plates, charts and identification of plant, equipment, cable, isolators and the like
Item
1
G
Allow for preparing schedule of manufacturers recommended tools and spare parts for each piece of equipment
Item
1
H
Allow for the provision of operating/maintenance manuals
Item
1
J
Allow for providing shop and coordination drawings
Item
1
K
Allow for domestic water piping, sterilization and disinfections after commissioning
Item
1
L
Allow for flushing chilled water system pipe work  with water and establishment of rust inhibitor before commissioning
Item
1
M
Allow for fire stopping in accordance with the drawings, specification and local authorities requirements
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1
BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS
Note:
Power System installations
Note:
Final Distribution Boards
Note:
Supply, install, test, commission and maintain Final Distribution boards and terminations including bus bars, breakers, indicators, all interconnecting cables, wires termination and trays from main board,  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Final distribution boards, DB-GU
No
1
Code
Description
Note:
Power Distribution
Note:
Supply and install the following power fittings including all necessary accessories and connections to wiring  and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
13A Twin switched socket
No
3
C
13A Switched spur outlet
No
1
D
13A Unswitched spur outlet
No
1
E
20A double pole switch
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2
BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Power System Installations (Cont'd)
Note:
Power point
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trucking, access box with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Power points
No
6
Code
Description
Note:
Isolating Switch
Note:
Supply and install isolating switch  including all interconnecting and terminations  and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Isolator three phase 32A IP65
No
1
Code
Description
Note:
Internal Lighting
Note:
Supply and install lighting including all necessary accessories  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Lighting fixture,  type S2
No
1
D
Ditto,  type S3
No
1
E
Ditto,  type W1
No
1
F
Ditto,  type L1
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3
BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Power System Installations (Cont'd)
Note:
Internal Lighting Points
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Internal Lighting points
No
5
Code
Description
Note:
Switches
Note:
Supply, install, test, commission switches including all necessary accessories  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Two gang, one way lighting switch 20A
No
1
C
Three gang, two way lighting switch 20A, W/P
No
1
Code
Description
Note:
Lighting switch Point
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
D
Lighting switch points
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4
BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Emergency and Exit Lighting System
Note:
Supply, install, test, commission  the following emergency and exit light fittings, including  ceiling rose, heat resistance, flexible cable, lamps, electronic control gear, suspensions, connections to permanent wiring system in accordance with Specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Self-contained 1x8w emergency light with built-in battery (3h duration ), surface-mounted, non-maintained
No
1
Code
Description
Note:
Emergency lighting points
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trunking, with all accessories,  and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Emergency lighting points
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5
BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Fire Alarm System
Note:
Supply, install, test, commission and maintain  the complete Analogue addressable fire Alarm & evacuation system including cabling, wiring conduit, cable tray, trunking, termination and power connections  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Intelligent optical smoke detector and standard base
No
1
B
Fire alarm sounder or horn W/P
No
1
C
Fire alarm junction box
No
1
D
Dual input module
No
1
E
Monitoring module
No
1
Code
Description
Note:
Earthing protection system
Note:
Supply, install, test and commissioning of earthing protection system including earth pits, conductors, bars ,bonds and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
F
Earthing protection
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6
BILL NO. 04 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Sundry / General Items
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for permits, connection and inspection fees associated with electrical installations by utility and statutory authorities
Item
1
B
Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings
Item
1
C
Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment
Item
1
D
Allow for setting out the works, marking positions of holes, mortises, chases or the like
Item
1
E
Allow for testing and commissioning and production of test certificates
Item
1
F
Allow for all identification labels, plates, charts and identification of plant, equipment, cable, switches and the like
Item
1
G
Allow for the provision of operating / maintenance manuals
Item
1
H
Allow for providing shop and coordination drawings
Item
1
J
Allow for instructing selected employer's personnel on all aspects of the operation of systems and equipment
Item
1
K
Supply and handover to the client all tools and equipment in accordance with the specification
Item
1
L
Allow for fire stopping in accordance with the drawings specification and local authorities requirements
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - SITE WORK - Page No. 2.1
BILL NO. 05 - SITE WORK - Page No. 2.1
Code
Description
Note:
DIVISION 02 - SITE WORKS
Note:
Site Preparation
Code
Description
Remarks
Unit of Measurement
Quantity
A
Site Clearance, including removal of rubbish, debris, vegetation, within the designated work area complete accordance with the specifications and drawings
m2
102
Code
Description
Note:
Excavation
Note:
Excavation from existing level to bottom of foundation levels complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Bulk Excavation
m3
40
C
Pit Excavation
m3
39
D
Trench Excavation
m3
59
Code
Description
Note:
Backfilling
Code
Description
Remarks
Unit of Measurement
Quantity
E
Backfilling, including compaction in layer complete in accordance with specifications and drawings
m3
83
Code
Description
Note:
Disposal of Material Arising From Excavations
Code
Description
Remarks
Unit of Measurement
Quantity
F
Remove surplus excavated material from site to approved location complete in accordance with specifications and drawings
m3
55
Code
Description
Note:
Road base
Code
Description
Remarks
Unit of Measurement
Quantity
G
Road base, including compaction in layer complete in accordance with specifications and drawings
m3
6
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - SITE WORK (CONT'D) - Page No. 2.2
BILL NO. 05 - SITE WORK (CONT'D) - Page No. 2.2
Code
Description
Note:
DIVISION 02 - SITE WORKS(CONT'D)
Note:
Anti - Termite Treatment
Note:
Allow for anti termite treatment under blinding and around building complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Laid horizontally
m2
102
B
Laid vertically
m2
128
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - CONCRETE WORK - Page No. 3.1
BILL NO. 05 - CONCRETE WORK - Page No. 3.1
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS
Note:
IN ACCORDANCE WITH SPECIFICATIONS AND DRAWINGS
Note:
Sub Structure
Note:
Plain concrete, C20/25 compressive strength with ordinary Portland cement, GGBS,  including shuttering,  additives, plasticizers, curing, vibrating,  and all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
100 mm thick Blinding
m3
11
Code
Description
Note:
Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating,   and all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Foundation
m3
8
C
Columns neck
m3
1
D
Slab on grade
m3
13
E
Ground beams
m3
9
F
Trench wall
m3
3
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - CONCRETE WORKS (Cont'd)- Page No. 3.2
BILL NO. 05 - CONCRETE WORKS (Cont'd)- Page No. 3.2
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS ( CONT`D)
Note:
Sub Structure (Cont`d)
Note:
Steel reinforcement
Note:
High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420  N/mm2 for shear design  complete in accordance with specification and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
A
10 mm diameter
kg
1,506.28
B
12 mm diameter
kg
1,318.7
C
16 mm diameter
kg
659
Code
Description
Note:
Shuttering
Note:
Temporary shuttering, standard finish complete in accordance with specifications and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
D
To sides of foundation
m2
17
E
To sides of columns neck
m2
13
F
To side of ground beam
m2
76
G
To side of trench wall
m2
79
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - CONCRETE WORKS (Cont'd)- Page No. 3.3
BILL NO. 05 - CONCRETE WORKS (Cont'd)- Page No. 3.3
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS ( CONT`D)
Note:
Super Structure
Note:
Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating,   and all necessary works, complete in accordance with specifications and drawings (Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Columns
m3
4
B
Slabs
m3
22
C
Beams
m3
5
Code
Description
Note:
Steel reinforcement
Note:
High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420  N/mm2 for shear design  complete in accordance with specification and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
D
10 mm diameter
kg
573.85
E
12 mm diameter
kg
2,531.49
F
16 mm diameter
kg
1,095.08
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - CONCRETE WORKS (Cont'd)- Page No. 3.4
BILL NO. 05 - CONCRETE WORKS (Cont'd)- Page No. 3.4
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS ( CONT`D)
Note:
Super Structure
Note:
Shuttering
Note:
Temporary shuttering, standard finish complete in accordance with specifications and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
A
To sides of columns
m2
44
B
To sides and soffits of slabs
m2
86
C
To sides and soffits of beams
m2
53
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - CONCRETE WORKS (Cont'd)- Page No. 3.5
BILL NO. 05 - CONCRETE WORKS (Cont'd)- Page No. 3.5
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS ( CONT`D)
Note:
CONCRETE SUNDRIES
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for all joints including isolation, control, construction and contraction  joints or the like as required all in accordance with the specifications and drawings
Item
1
B
Allow for equipment base concrete as required all in accordance with the specifications and drawings
Item
1
C
Allow for structural opening for MEP services and networks throw slabs, beams, columns and foundations all in accordance with the specifications and drawings
Item
1
D
Allow for all builders work in connection with the whole of MEP works including all manholes, sumps, pits, etc.
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - MASONARY WORKS - Page No. 4.1
BILL NO. 05 - MASONARY WORKS - Page No. 4.1
Code
Description
Note:
DIVISION 04 - MASONRY WORKS
Note:
External Block Work
Note:
External CMU hollow normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref.W-04, 200mm thick
m2
130
Code
Description
Note:
Internal CMU hollow normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref.W-04, 200mm thick
m2
16
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - MASONARY WORKS - Page No. 4.2
BILL NO. 05 - MASONARY WORKS - Page No. 4.2
Code
Description
Note:
DIVISION 04 - MASONRY WORKS
Note:
Masonry Sundries
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for control joint complete in accordance with specification and drawing
Item
1
B
Allow for fire sealant complete in accordance with specification and drawing
Item
1
C
Allow for all opening and builder works for all MEP services in connection with masonry works all complete in accordance with specification and drawing
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - METAL WORK - Page No. 5.1
BILL NO. 05 - METAL WORK - Page No. 5.1
Code
Description
Note:
DIVISION 05 - METAL WORKS
Note:
Non Structural Metal Work
Note:
Ladders
Note:
Supply and install galvanized steel ladder including rungs, side rails, safety cage, frame, steel brackets, supports, anchors, bolts, fixing, fittings, accessories and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Access cat ladder, 800x5560 mm height
No
1
Code
Description
Note:
Aluminum Louvers
Note:
Supply and install aluminum louvers decorative powder coated aluminum screens, decorative powder coated aluminum frame and steel support  including   all fittings, accessories and fixings complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref. AL-03, Aluminum louvers, size 3900mm x 2150mm
No
1
Code
Description
Note:
Trench Grating
Note:
Supply and install trench grating including fixing in position, fittings, accessories and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Trench Grating
m2
22
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - THERMAL & MOISTURE PROTECTION - Page No. 7.1
BILL NO. 05 - THERMAL & MOISTURE PROTECTION - Page No. 7.1
Code
Description
Note:
DIVISION 07 - THERMAL & MOISTURE PROTECTION
Note:
Substructure Waterproofing
Note:
Supply and apply 1000guage polyethylene separation sheet, complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Laid horizontally, under slab on grade
m2
87
Code
Description
Note:
Supply and apply 1 layer of 4mm THK. each waterproofing membrane torch applied, complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Laid horizontally, under and above foundation
m2
38
C
Laid horizontally, under ground beam
m2
18
D
Laid vertically, side foundation
m2
17
E
Laid vertically, column neck
m2
13
F
Laid vertically, side ground beam
m2
76
G
Laid vertically, side trench wall
m2
39
Code
Description
Note:
Protection board
Note:
Supply and install seal tight protection board complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
H
Laid vertically & horizontally, 6mm thick
m2
145
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - THERMAL & MOISTURE PROTECTION - Page No. 7.2
BILL NO. 05 - THERMAL & MOISTURE PROTECTION - Page No. 7.2
Code
Description
Note:
DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT'D)
Note:
Roof Waterproofing System
Note:
Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings
Note:
Laid Horizontally
Code
Description
Remarks
Unit of Measurement
Quantity
A
Roof cement tiles, Size 300x300
m2
78
B
Polyflex combo-top coat (1000 mic thick), sri > 78 as per green building regulation
m2
78
C
SBR bonding agent
m2
78
D
Concrete screed (26n/mm 2-350opc, 80mm ave. thickness)
m2
78
E
Polyfab filter membrane (  1200mic thick)
m2
78
F
Polytex liquid U.V. protection coat ( 600mic thick)
m2
78
G
Polyurethane foam of thickness 110mm with  45-50kg/m  3density
m2
78
H
Light weight foam concrete, 50mm mni thickness. sloped to drain 2%
m2
78
J
Polybond bonding agent
m2
78
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - THERMAL & MOISTURE PROTECTION - Page No. 7.3
BILL NO. 05 - THERMAL & MOISTURE PROTECTION - Page No. 7.3
Code
Description
Note:
DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT'D)
Note:
Roof Waterproofing System ( Cont`d)
Note:
Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings (Cont`d)
Note:
Laid Vertically
Code
Description
Remarks
Unit of Measurement
Quantity
A
Brush applied polytex -hr top coat ( 1000mic thick) sri > 78
m
78
B
Fabric reinforcement
m
39
C
Angle Fillet, 100x100mm
m
39
D
Polybond bonding agent
m
39
E
polyfab filter membrane (  1200mic thick)
m
39
F
Polyurethane foam of thickness 110mm with  45-50kg/m  3density
m
39
G
Aluminum flashing
m
39
Code
Description
Note:
Sundries
Code
Description
Remarks
Unit of Measurement
Quantity
H
Allow for waterproofing dressing around rain water outlet
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - DOORS & WINDOWS - Page No. 8.1
BILL NO. 05 - DOORS & WINDOWS - Page No. 8.1
Code
Description
Note:
DIVISION 08 - DOORS AND WINDOWS
Note:
External Hollow Metal Doors
Note:
Aluminium Louver Doors
Note:
Supply and install aluminium louver doors with powder coated finish including frame, ironmongeries, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref AL01, size 3050x2750mm
No
1
B
Ref AL02, size 1500x2490mm
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - FINISHES  - Page No. 9.1
BILL NO. 05 - FINISHES  - Page No. 9.1
Code
Description
Note:
DIVISION 09 - FINISHES
Note:
Internal Finishes
Note:
Backgrounds
Note:
Floor Screed
Note:
Supply and install cement and sand screed with self levelling compound; including sand filling, surface preparation, and all necessary works; all in according to drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
A
To receive Epoxy Paint
m2
78
Code
Description
Note:
Plaster
Note:
Supply and install 20mm thick cement and sand plaster to block or concrete walls and columns including metal lath and all necessary works complete  in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
To receive paint finish
m2
53
Code
Description
Note:
Supply and install cement sand plaster to soffits including all necessary works complete  in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
To receive paint finish
m2
78
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - FINISHES  - Page No. 9.2
BILL NO. 05 - FINISHES  - Page No. 9.2
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
Internal Finishes (Cont'd)
Note:
Floor Finishes
Note:
Supply and apply  Heavy duty free solvent epoxy coating including all necessary works complete in accordance with specifications and drawings (Screed measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref-FF04
m2
78
Code
Description
Note:
Skirting
Note:
Supply and apply epoxy skirting including surface preparation,  primer coat, final coat and all necessary works complete in accordance with specifications  and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref-Sk02
m
46
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - FINISHES  - Page No. 9.3
BILL NO. 05 - FINISHES  - Page No. 9.3
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
Internal Finishes (Cont'd)
Note:
Painting and Decoration
Note:
Supply and apply paint finish including surface preparation, primer coat, final coat and all necessary works complete in accordance with specifications  and drawings (Plaster measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
A
To walls,  paint, Ref-WF01
m2
127
B
To plastered soffits, paint, Ref-CL03
m2
78
Code
Description
Note:
External Finishes
Note:
Plaster
Note:
Supply and install cement and sand plaster to block or concrete walls and columns including metal lath, grooves and all necessary works complete  in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
To external block or concrete walls and columns, to receive paint finish
m2
229
Code
Description
Note:
Painting and Decoration
Note:
Supply and apply paint finish including surface preparation,  primer coat, final coat and all necessary works complete in accordance with specifications  and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
D
To plastered walls, paint
m2
229
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 -MECH INSTALLATION - Page No. 15.1
BILL NO. 05 -MECH INSTALLATION - Page No. 15.1
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS
Note:
Rainwater, soil,  waste, and vent pipework installations complete in accordance with specifications and drawings
Note:
Pipework
Note:
Above ground uPVC pipework including fittings, accessories, insect screen, and all necessary works complete in accordance with drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
A
110mm diameter
m
9
Code
Description
Note:
Fittings, complete in accordance with drawings and specifications
Note:
Rain Water Drain
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref. RWO, 110mm diameter
No
2
Code
Description
Note:
Fire Fighting System
Note:
Fire Extinguisher
Note:
Supply install test and commission fire extinguisher including but not limited to wall fixing frame and hanger and all required components and accessories as per drawings, specifications and civil defense regulations.
Code
Description
Remarks
Unit of Measurement
Quantity
C
2 Kg dry CO2 fire extinguisher
No
1
D
12 Kg dry CO2 trolly type
No
1
Code
Description
Note:
Building Management System (BMS)
Code
Description
Remarks
Unit of Measurement
Quantity
E
Supply, install, test and commissioning  of Building management system including points, wires, conduits, and  all necessary works complete in accordance with specifications and drawings
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 -MECH INSTALLATION (Cont'd) - Page No. 15.2
BILL NO. 05 -MECH INSTALLATION (Cont'd) - Page No. 15.2
Code
Description
Note:
Sundry / General Items
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for permits, connection and inspection fees associated with mechanical installations by utility and statutory authorities
Item
1
B
Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings
Item
1
C
Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment
Item
1
D
Allow for setting out the works, marking positions of holes, mortises, chases or the like
Item
1
E
Allow for testing and commissioning and submission of test certificates
Item
1
F
Allow for all identification labels, plates, charts and identification of plant, equipment, cable, isolators and the like
Item
1
G
Allow for preparing schedule of manufacturers recommended tools and spare parts for each piece of equipment
Item
1
H
Allow for the provision of operating/maintenance manuals
Item
1
J
Allow for providing shop and coordination drawings
Item
1
K
Allow for domestic water piping, sterilization and disinfections after commissioning
Item
1
L
Allow for fire stopping in accordance with the drawings, specification and local authorities requirements
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1
BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS
Note:
Capacitor Bank Panel
Note:
Supply, install, test and commission Multi step automatic switching capacitor bank with reactive power regulator including ,MCCB's, terminations, supports, accessories,  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Capacitor bank panel, 300 KVAR
No
1
Code
Description
Note:
Main &Sub Main Distribution Boards
Note:
Supply, install, test, commission, and maintain main and sub-main distribution boards and terminations, including bus bars, breakers, indicators,  meters, all interconnecting cables, wires termination, energy monitoring meters, and trays from the main board,  and all necessary works complete in accordance with specification and drawings
Note:
Main Distribution Boards
Code
Description
Remarks
Unit of Measurement
Quantity
B
Main distribution boards, ref LVP-03
No
1
Code
Description
Note:
Sub Main Distribution Boards
Code
Description
Remarks
Unit of Measurement
Quantity
C
Sub main distribution boards, ref SMDB-SERV
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2
BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Power System Installations (Cont'd)
Note:
Final Distribution Boards
Note:
Supply, install, test, commission and maintain Final Distribution boards and terminations including bus bars, breakers, indicators, all interconnecting cables, wires termination and trays from main board,  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Final distribution boards, DB-SS
No
1
B
Ditto, DB-LV
No
1
Code
Description
Note:
Cables
B
Low Voltage cables including ducts, glands, connections, conduits, termination, trays  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
2C 6mm2 XLPE/SWA/CU/PVC+ 1C.6mm2 ECC
m
15
B
4C 6mm2 XLPE/SWA/PVC+ 1C.6mm2 PVC/ECC/CU
m
11
C
4C 70mm2 XLPE/SWA/PVC+ 1C.35mm2 CPC
m
15
D
2x4C 300mm2 XLPE/SWA/PVC+ 2x1C.150mm2 CPC
m
9
Code
Description
Note:
Power Distribution
Note:
Supply and install the following power fittings including all necessary accessories and connections to wiring  and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
E
13A Single switched socket
No
2
F
13A Twin switched socket
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3
BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Power System Installations (Cont'd)
Note:
Power point
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trucking, access box with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Power points
No
4
Code
Description
Note:
Isolating Switch
Note:
Supply and install isolating switch  including all interconnecting and terminations  and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Isolator single phase 32A, weather proof
No
2
Code
Description
Note:
Internal Lighting
Note:
Supply and install lighting including all necessary accessories  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Lighting fixture,  type W1
No
2
D
Ditto,  type B1
No
15
Code
Description
Note:
Internal Lighting Points
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
E
Internal Lighting points
No
17
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4
BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Power System Installations (Cont'd)
Note:
Switches
Note:
Supply, install, test, commission switches including all necessary accessories  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Two gang, one way lighting switch 20A
No
1
B
Three gang, one way lighting switch 20A
No
1
Code
Description
Note:
Lighting switch Point
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
Code / Note Title
Lighting switch points
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5
BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Emergency and Exit Lighting System
Note:
Supply, install, test, commission  the following emergency and exit light fittings, including  ceiling rose, heat resistance, flexible cable, lamps, electronic control gear, suspensions, connections to permanent wiring system in accordance with Specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
1x4w LED, self-contained non-maintained type with monitoring module, 3-hour duration back-up battery, IP-54 (type-EL-1) surface mounted
No
1
B
1x3w LED, self-contained, maintained exit light, wall-mounted, 3-hour duration back-up battery, IP-54
No
2
Code
Description
Note:
Emergency lighting points
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trunking, with all accessories,  and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Emergency lighting points
No
3
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6
BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Fire Alarm System
Note:
Supply, install, test, commission and maintain  the complete Analogue addressable fire Alarm & evacuation system including cabling, wiring conduit, cable tray, trunking, termination and power connections  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Addressable optical smoke detector
No
1
B
Fire alarm junction box
No
1
C
Multi sensor detector
No
2
D
Fire alarm sounder with flasher, weather proof
No
1
E
Manual call point, weather proof
No
1
Code
Description
Note:
Earthing protection system
Note:
Supply, install, test and commissioning of earthing protection system including earth pits, conductors, bars ,bonds and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
F
Earthing protection
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.7
BILL NO. 05 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.7
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Sundry / General Items
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for permits, connection and inspection fees associated with electrical installations by utility and statutory authorities
Item
1
B
Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings
Item
1
C
Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment
Item
1
D
Allow for setting out the works, marking positions of holes, mortises, chases or the like
Item
1
E
Allow for testing and commissioning and production of test certificates
Item
1
F
Allow for all identification labels, plates, charts and identification of plant, equipment, cable, switches and the like
Item
1
G
Allow for the provision of operating / maintenance manuals
Item
1
H
Allow for providing shop and coordination drawings
Item
1
J
Allow for instructing selected employer's personnel on all aspects of the operation of systems and equipment
Item
1
K
Supply and handover to the client all tools and equipment in accordance with the specification
Item
1
L
Allow for fire stopping in accordance with the drawings specification and local authorities requirements
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - SITE WORK - Page No. 2.1
BILL NO. 06 - SITE WORK - Page No. 2.1
Code
Description
Note:
DIVISION 02 - SITE WORKS
Note:
Site Preparation
Code
Description
Remarks
Unit of Measurement
Quantity
A
Site Clearance, including removal of rubbish, debris, vegetation, within the designated work area complete accordance with the specifications and drawings
m2
17
Code
Description
Note:
Excavation
Note:
Excavation from existing level to bottom of foundation levels complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Bulk Excavation
m3
11
C
Pit Excavation
m3
3
D
Trench Excavation
m3
13
Code
Description
Note:
Backfilling
Code
Description
Remarks
Unit of Measurement
Quantity
E
Backfilling, including compaction in layer complete in accordance with specifications and drawings
m3
17
Code
Description
Note:
Disposal of Material Arising From Excavations
Code
Description
Remarks
Unit of Measurement
Quantity
F
Remove surplus excavated material from site to approved location complete in accordance with specifications and drawings
m3
10
Code
Description
Note:
Road base
Code
Description
Remarks
Unit of Measurement
Quantity
G
Road base, including compaction in layer complete in accordance with specifications and drawings
m3
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - SITE WORK (CONT'D) - Page No. 2.2
BILL NO. 06 - SITE WORK (CONT'D) - Page No. 2.2
Code
Description
Note:
DIVISION 02 - SITE WORKS(CONT'D)
Note:
Anti - Termite Treatment
Note:
Allow for anti termite treatment under blinding and around building complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Laid horizontally
m2
17
B
Laid vertically
m2
42
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - CONCRETE WORK - Page No. 3.1
BILL NO. 06 - CONCRETE WORK - Page No. 3.1
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS
Note:
IN ACCORDANCE WITH SPECIFICATIONS AND DRAWINGS
Note:
Sub Structure
Note:
Plain concrete, C20/25 compressive strength with ordinary Portland cement, GGBS,  including shuttering,  additives, plasticizers, curing, vibrating,  and all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
100 mm thick Blinding
m3
3
Code
Description
Note:
Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating,   and all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Foundation
m3
2
C
Columns neck
m3
1
D
Slab on grade
m3
2
E
Ground beams
m3
2
F
Trench wall
m3
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - CONCRETE WORKS (Cont'd)- Page No. 3.2
BILL NO. 06 - CONCRETE WORKS (Cont'd)- Page No. 3.2
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS ( CONT`D)
Note:
Sub Structure (Cont`d)
Note:
Steel reinforcement
Note:
High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420  N/mm2 for shear design  complete in accordance with specification and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
A
10 mm diameter
kg
307.76
B
12 mm diameter
kg
336.94
C
16 mm diameter
kg
241
Code
Description
Note:
Shuttering
Note:
Temporary shuttering, standard finish complete in accordance with specifications and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
D
To sides of foundation
m2
7
E
To sides of columns neck
m2
13
F
To side of ground beam
m2
22
G
To side of trench wall
m2
12
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - CONCRETE WORKS (Cont'd)- Page No. 3.3
BILL NO. 06 - CONCRETE WORKS (Cont'd)- Page No. 3.3
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS ( CONT`D)
Note:
Super Structure
Note:
Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating,   and all necessary works, complete in accordance with specifications and drawings (Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Columns
m3
1
B
Slabs
m3
2
C
Beams
m3
1
Code
Description
Note:
Steel reinforcement
Note:
High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420  N/mm2 for shear design  complete in accordance with specification and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
D
10 mm diameter
kg
175.48
E
12 mm diameter
kg
352.77
F
16 mm diameter
kg
337
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - CONCRETE WORKS (Cont'd)- Page No. 3.4
BILL NO. 06 - CONCRETE WORKS (Cont'd)- Page No. 3.4
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS ( CONT`D)
Note:
Super Structure
Note:
Shuttering
Note:
Temporary shuttering, standard finish complete in accordance with specifications and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
A
To sides of columns
m2
19
B
To sides and soffits of slabs
m2
12
C
To sides and soffits of beams
m2
13
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - CONCRETE WORKS (Cont'd)- Page No. 3.5
BILL NO. 06 - CONCRETE WORKS (Cont'd)- Page No. 3.5
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS ( CONT`D)
Note:
CONCRETE SUNDRIES
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for all joints including isolation, control, construction and contraction  joints or the like as required all in accordance with the specifications and drawings
Item
1
B
Allow for equipment base concrete as required all in accordance with the specifications and drawings
Item
1
C
Allow for structural opening for MEP services and networks throw slabs, beams, columns and foundations all in accordance with the specifications and drawings
Item
1
D
Allow for all builders work in connection with the whole of MEP works including all manholes, sumps, pits, etc.
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - MASONARY WORKS - Page No. 4.1
BILL NO. 06 - MASONARY WORKS - Page No. 4.1
Code
Description
Note:
DIVISION 04 - MASONRY WORKS
Note:
External Block Work
Note:
External CMU hollow normal weight block walls, bedded, jointed and pointed in cement sand mortar including metal lath, solid jambs at openings, reinforcement, stiffener beams, stiffener columns, lintels, sills and capping beams all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref.W-04, 200mm thick
m2
36
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - MASONARY WORKS - Page No. 4.2
BILL NO. 06 - MASONARY WORKS - Page No. 4.2
Code
Description
Note:
DIVISION 04 - MASONRY WORKS
Note:
Masonry Sundries
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for control joint complete in accordance with specification and drawing
Item
1
B
Allow for fire sealant complete in accordance with specification and drawing
Item
1
C
Allow for all opening and builder works for all MEP services in connection with masonry works all complete in accordance with specification and drawing
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - METAL WORK - Page No. 5.1
BILL NO. 06 - METAL WORK - Page No. 5.1
Code
Description
Note:
DIVISION 05 - METAL WORKS
Note:
Non Structural Metal Work
Note:
Aluminum Louvers
Note:
Supply and install aluminum louvers decorative powder coated aluminum screens, decorative powder coated aluminum frame and steel support  including   all fittings, accessories and fixings complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Aluminum louvers, size 2650mm x 2150mm
No
1
Code
Description
Note:
Trench Grating
Note:
Supply and install trench grating including fixing in position, fittings, accessories and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Trench Grating
m2
3
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - THERMAL & MOISTURE PROTECTION - Page No. 7.1
BILL NO. 06 - THERMAL & MOISTURE PROTECTION - Page No. 7.1
Code
Description
Note:
DIVISION 07 - THERMAL & MOISTURE PROTECTION
Note:
Substructure Waterproofing
Note:
Supply and apply 1000guage polyethylene separation sheet, complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Laid horizontally, under slab on grade
m2
12
Code
Description
Note:
Supply and apply 1 layer of 4mm THK. each waterproofing membrane torch applied, complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Laid horizontally, under and above foundation
m2
9
C
Laid horizontally, under ground beam
m2
24
D
Laid vertically, side foundation
m2
7
E
Laid vertically, column neck
m2
13
F
Laid vertically, side ground beam
m2
22
G
Laid vertically, side trench wall
m2
6
Code
Description
Note:
Protection board
Note:
Supply and install seal tight protection board complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
H
Laid vertically & horizontally, 6mm thick
m2
48
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - THERMAL & MOISTURE PROTECTION - Page No. 7.2
BILL NO. 06 - THERMAL & MOISTURE PROTECTION - Page No. 7.2
Code
Description
Note:
DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT'D)
Note:
Roof Waterproofing System
Note:
Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings
Note:
Laid Horizontally
Code
Description
Remarks
Unit of Measurement
Quantity
A
Roof cement tiles, Size 300x300
m2
9
B
Polyflex combo-top coat (1000 mic thick), sri > 78 as per green building regulation
m2
9
C
SBR bonding agent
m2
9
D
Concrete screed (26n/mm 2-350opc, 80mm ave. thickness)
m2
9
E
Polyfab filter membrane (  1200mic thick)
m2
9
F
Polytex liquid U.V. protection coat ( 600mic thick)
m2
9
G
Polyurethane foam of thickness 110mm with  45-50kg/m  3density
m2
9
H
Light weight foam concrete, 50mm mni thickness. sloped to drain 2%
m2
9
J
Polybond bonding agent
m2
9
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - THERMAL & MOISTURE PROTECTION - Page No. 7.3
BILL NO. 06 - THERMAL & MOISTURE PROTECTION - Page No. 7.3
Code
Description
Note:
DIVISION 07 - THERMAL & MOISTURE PROTECTION (CONT'D)
Note:
Roof Waterproofing System ( Cont`d)
Note:
Roof waterproofing system including surface preparation, backing, sealant and all necessary works complete in accordance with the specifications and drawings (Cont`d)
Note:
Laid Vertically
Code
Description
Remarks
Unit of Measurement
Quantity
A
Brush applied polytex -hr top coat ( 1000mic thick) sri > 78
m
12
B
Fabric reinforcement
m
12
C
Angle Fillet, 100x100mm
m
12
D
Polybond bonding agent
m
12
E
polyfab filter membrane (  1200mic thick)
m
12
F
Polyurethane foam of thickness 110mm with  45-50kg/m  3density
m
12
G
Aluminum flashing
m
12
Code
Description
Note:
Sundries
Code
Description
Remarks
Unit of Measurement
Quantity
H
Allow for waterproofing dressing around rain water outlet
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - DOORS & WINDOWS - Page No. 8.1
BILL NO. 06 - DOORS & WINDOWS - Page No. 8.1
Code
Description
Note:
DIVISION 08 - DOORS AND WINDOWS
Note:
External Hollow Metal Doors
Note:
Aluminium Louver Doors
Note:
Supply and install aluminium louver doors with powder coated finish including frame, ironmongeries, fixing,  fittings and all necessary works  complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref AL01, size 3040x2750mm
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - FINISHES  - Page No. 9.1
BILL NO. 06 - FINISHES  - Page No. 9.1
Code
Description
Note:
DIVISION 09 - FINISHES
Note:
Internal Finishes
Note:
Backgrounds
Note:
Floor Screed
Note:
Supply and install cement and sand screed with self levelling compound; including sand filling, surface preparation, and all necessary works; all in according to drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
A
To receive Epoxy Paint
m2
10
Code
Description
Note:
Plaster
Note:
Supply and install 20mm thick cement and sand plaster to block or concrete walls and columns including metal lath and all necessary works complete  in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
To receive paint finish
m2
33
Code
Description
Note:
Supply and install cement sand plaster to soffits including all necessary works complete  in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
To receive paint finish
m2
10
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - FINISHES  - Page No. 9.2
BILL NO. 06 - FINISHES  - Page No. 9.2
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
Internal Finishes (Cont'd)
Note:
Floor Finishes
Note:
Supply and apply  Heavy duty free solvent epoxy coating including all necessary works complete in accordance with specifications and drawings (Screed measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref-FF04
m2
10
Code
Description
Note:
Skirting
Note:
Supply and apply epoxy skirting including surface preparation,  primer coat, final coat and all necessary works complete in accordance with specifications  and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref-Sk02
m
10
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - FINISHES  - Page No. 9.3
BILL NO. 06 - FINISHES  - Page No. 9.3
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
Internal Finishes (Cont'd)
Note:
Painting and Decoration
Note:
Supply and apply paint finish including surface preparation, primer coat, final coat and all necessary works complete in accordance with specifications  and drawings (Plaster measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
A
To walls,  paint, Ref-WF01
m2
33
B
To plastered soffits, paint, Ref-CL03
m2
10
Code
Description
Note:
External Finishes
Note:
Floor Screed
Note:
Supply and install cement and sand screed with self levelling compound; including sand filling, surface preparation, and all necessary works; all in according to drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
C
To receive Terrazo Tiles
m2
9
Code
Description
Note:
Plaster
Note:
Supply and install cement and sand plaster to block or concrete walls and columns including metal lath and all necessary works complete  in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
D
To external block or concrete walls and columns, to receive paint finish
m2
85
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - FINISHES  - Page No. 9.4
BILL NO. 06 - FINISHES  - Page No. 9.4
Code
Description
Note:
DIVISION 09 - FINISHES(CONT'D)
Note:
External Finishes(Cont'd)
Note:
Supply and Install terrazo roofing including bedding materials, grouting, jointing and all necessary works complete in accordance with specifications and drawings (Screed measured separately)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Terrazo roofing
m2
10
Code
Description
Note:
Painting and Decoration
Note:
Supply and apply paint finish including surface preparation,  primer coat, final coat and all necessary works complete in accordance with specifications  and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
To plastered walls, paint
m2
85
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 -MECH INSTALLATION - Page No. 15.1
BILL NO. 06 -MECH INSTALLATION - Page No. 15.1
Code
Description
Note:
DIVISION 15 - MECHANICAL INSTALLATIONS
Note:
Rainwater, soil,  waste, and vent pipework installations complete in accordance with specifications and drawings
Note:
Pipework
Note:
Above ground uPVC pipework including fittings, accessories, insect screen, and all necessary works complete in accordance with drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
A
110mm diameter
m
4
Code
Description
Note:
Fittings, complete in accordance with drawings and specifications
Note:
Rain Water Drain
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref. RWO, 110mm diameter
No
1
Code
Description
Note:
Fire Fighting System
Note:
Fire Extinguisher
Note:
Supply install test and commission fire extinguisher including but not limited to wall fixing frame and hanger and all required components and accessories as per drawings, specifications and civil defense regulations.
Code
Description
Remarks
Unit of Measurement
Quantity
C
5 Kg dry CO2 fire extinguisher
No
1
Code
Description
Note:
Building Management System (BMS)
Code
Description
Remarks
Unit of Measurement
Quantity
D
Supply, install, test and commissioning  of Building management system including points, wires, conduits, and  all necessary works complete in accordance with specifications and drawings
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 -MECH INSTALLATION (Cont'd) - Page No. 15.2
BILL NO. 06 -MECH INSTALLATION (Cont'd) - Page No. 15.2
Code
Description
Note:
Sundry / General Items
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for permits, connection and inspection fees associated with mechanical installations by utility and statutory authorities
Item
1
B
Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings
Item
1
C
Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment
Item
1
D
Allow for setting out the works, marking positions of holes, mortises, chases or the like
Item
1
E
Allow for testing and commissioning and submission of test certificates
Item
1
F
Allow for all identification labels, plates, charts and identification of plant, equipment, cable, isolators and the like
Item
1
G
Allow for preparing schedule of manufacturers recommended tools and spare parts for each piece of equipment
Item
1
H
Allow for the provision of operating/maintenance manuals
Item
1
J
Allow for providing shop and coordination drawings
Item
1
K
Allow for domestic water piping, sterilization and disinfections after commissioning
Item
1
L
Allow for fire stopping in accordance with the drawings, specification and local authorities requirements
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1
BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS
Note:
Final Distribution Boards
Note:
Supply, install, test, commission and maintain Final Distribution boards and terminations including bus bars, breakers, indicators, all interconnecting cables, wires termination and trays from main board,  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Final distribution boards, DB-RMU
No
1
Code
Description
Note:
Power Distribution
Note:
Supply and install the following power fittings including all necessary accessories and connections to wiring  and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
13A Single switched socket
No
1
Code
Description
Note:
Power point
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trucking, access box with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Power points
No
1
Code
Description
Note:
Internal Lighting
Note:
Supply and install lighting including all necessary accessories  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
D
Lighting fixture,  type W1
No
1
E
Ditto,  type B1
No
3
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2
BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Power System Installations (Cont'd)
Note:
Internal Lighting Points
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Internal Lighting points
No
4
Code
Description
Note:
Switches
Note:
Supply, install, test, commission switches including all necessary accessories  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Two gang, one way lighting switch 20A
No
1
Code
Description
Note:
Lighting switch Point
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Lighting switch points
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3
BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Emergency and Exit Lighting System
Note:
Supply, install, test, commission  the following emergency and exit light fittings, including  ceiling rose, heat resistance, flexible cable, lamps, electronic control gear, suspensions, connections to permanent wiring system in accordance with Specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Self-contained 1x8w emergency light with built-in battery (3h duration ), surface-mounted, non-maintained
No
1
Code
Description
Note:
Emergency lighting points
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trunking, with all accessories,  and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Emergency lighting points
No
1
Code
Description
Note:
Fire Alarm System
Note:
Supply, install, test, commission and maintain  the complete Analogue addressable fire Alarm & evacuation system including cabling, wiring conduit, cable tray, trunking, termination and power connections  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
Intelligent optical smoke detector and standard base
No
1
D
Fire alarm junction box
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4
BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Earthing protection system
Note:
Supply, install, test and commissioning of earthing protection system including earth pits, conductors, bars ,bonds and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Earthing protection
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5
BILL NO. 06 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Sundry / General Items
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for permits, connection and inspection fees associated with electrical installations by utility and statutory authorities
Item
1
B
Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings
Item
1
C
Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment
Item
1
D
Allow for setting out the works, marking positions of holes, mortises, chases or the like
Item
1
E
Allow for testing and commissioning and production of test certificates
Item
1
F
Allow for all identification labels, plates, charts and identification of plant, equipment, cable, switches and the like
Item
1
G
Allow for the provision of operating / maintenance manuals
Item
1
H
Allow for providing shop and coordination drawings
Item
1
J
Allow for instructing selected employer's personnel on all aspects of the operation of systems and equipment
Item
1
K
Supply and handover to the client all tools and equipment in accordance with the specification
Item
1
L
Allow for fire stopping in accordance with the drawings specification and local authorities requirements
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 - SITE WORK - Page No. 2.1
BILL NO. 07 - SITE WORK - Page No. 2.1
Code
Description
Note:
DIVISION 02 - SITE WORKS
Note:
Site Preparation
Code
Description
Remarks
Unit of Measurement
Quantity
A
Site Clearance, including removal of rubbish, debris, vegetation, within the designated work area complete accordance with the specifications and drawings
m2
258
Code
Description
Note:
Excavation
Note:
Excavation from existing level to bottom of foundation levels complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Bulk Excavation
m3
1,034
Code
Description
Note:
Backfilling
Code
Description
Remarks
Unit of Measurement
Quantity
C
Backfilling, including compaction in layer complete in accordance with specifications and drawings
m3
26
Code
Description
Note:
Disposal of Material Arising From Excavations
Code
Description
Remarks
Unit of Measurement
Quantity
D
Remove surplus excavated material from site to approved location complete in accordance with specifications and drawings
m3
1,008
Code
Description
Note:
Road base
Code
Description
Remarks
Unit of Measurement
Quantity
E
Road base, including compaction in layer complete in accordance with specifications and drawings
m3
64
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 - SITE WORK (CONT'D) - Page No. 2.2
BILL NO. 07 - SITE WORK (CONT'D) - Page No. 2.2
Code
Description
Note:
DIVISION 02 - SITE WORKS(CONT'D)
Note:
Anti - Termite Treatment
Note:
Allow for anti termite treatment under blinding and around building complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Laid horizontally
m2
258
B
Laid vertically
m2
282
Code
Description
Note:
Dewatering
Code
Description
Remarks
Unit of Measurement
Quantity
C
Allow for the provision, maintenance and removal on completion of the dewatering system in accordance with specification and drawing
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 - CONCRETE WORK - Page No. 3.1
BILL NO. 07 - CONCRETE WORK - Page No. 3.1
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS
Note:
IN ACCORDANCE WITH SPECIFICATIONS AND DRAWINGS
Note:
Sub Structure
Note:
Plain concrete, C20/25 compressive strength with ordinary Portland cement, GGBS,  including shuttering,  additives, plasticizers, curing, vibrating,  and all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
100 mm thick Blinding
m3
26
Code
Description
Note:
Reinforced concrete, C40/50 compressive strength with ordinary Portland cement, GGBS, including additives, plasticizers, curing, vibrating,   and all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Raft
m3
100
C
Wall below grade
m3
77
D
Slab
m3
74
Code
Description
Note:
Steel Reinforcement
Note:
High grade steel deformed bar reinforcement 460 N/mm2 for flexural design & 420  N/mm2 for shear design  complete in accordance with specification and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
E
12 mm diameter
Kg
9,248.87
F
16 mm diameter
Kg
18,667.7
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 - CONCRETE WORKS (Cont'd)- Page No. 3.2
BILL NO. 07 - CONCRETE WORKS (Cont'd)- Page No. 3.2
Code
Description
Note:
DIVISION 03 - CONCRETE WORKS
Note:
IN ACCORDANCE WITH SPECIFICATIONS AND DRAWINGS
Note:
Sub Structure (Cont`d)
Note:
Shuttering
Note:
Temporary shuttering, standard finish including all necessary works complete in accordance with specifications and drawing
Code
Description
Remarks
Unit of Measurement
Quantity
A
To sides of raft
m2
28
B
To sides of wall below grade
m2
509
C
To sides and soffits of slabs
m2
247.77
Code
Description
Note:
Water Stop
Note:
Allow for PVC water stop as required all in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
D
Water Stop
m
84
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 - CONCRETE WORKS (Cont'd)- Page No. 3.3
BILL NO. 07 - CONCRETE WORKS (Cont'd)- Page No. 3.3
Code
Description
Note:
SECTION C - CONCRETE WORKS(CONT'D)
Note:
CONCRETE SUNDRIES
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for all joints including isolation, control, construction and contraction  joints or the like as required all in accordance with the specifications and drawings
Item
1
B
Allow for equipment base concrete as required all in accordance with the specifications and drawings
Item
1
C
Allow for structural opening for MEP services and networks throw slabs, beams, columns and foundations all in accordance with the specifications and drawings
Item
1
D
Allow for all builders work in connection with the whole of MEP works including all manholes, sumps, pits, etc.
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 - METAL WORK - Page No. 5.1
BILL NO. 07 - METAL WORK - Page No. 5.1
Code
Description
Note:
SECTION E - METAL WORKS
Note:
Non Structural Metal Work
Note:
Ladders
Note:
Supply and install tread with triangular support stiffener 4mm thick weld fixed with CHS steel center column including fixing brackets, plates, anchors, protective layer, base plate including fixing, fittings, accessories and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
steel ladder 2600mm high, 600mm tread
No
1
Code
Description
Note:
Access Hatch and Covers
Note:
Supply and install access opening with double seal heavy duty cover including frames, fixing, fittings, accessories and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Size 1500x1500mm
No
1
C
Size 600x600mm
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 - THERMAL & MOISTURE PROTECTION - Page No. 7.1
BILL NO. 07 - THERMAL & MOISTURE PROTECTION - Page No. 7.1
Code
Description
Note:
SECTION G -THERMAL & MOISTURE PROTECTION
Note:
IN ACCORDANCE WITH SPECIFICATIONS AND DRAWINGS
Note:
SUB STRUCTURAL WATERPROOF
Note:
Supply and apply 1000guage polyethylene separation sheet, complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Laid horizontally, under raft
m2
258
Code
Description
Note:
Supply and apply 1 layer of 4mm THK. each waterproofing membrane torch applied, complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Laid horizontally, under raft
m2
231
C
Laid vertically, side raft
m2
35
D
Laid vertically, wall below
m2
226
E
Laid horizontally, Above slab
m2
251
Code
Description
Note:
Protection board
Note:
Supply and install seal tight protection board complete in accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
F
Laid vertically & horizontally, 6mm thick
m2
254
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 - THERMAL & MOISTURE PROTECTION - Page No. 7.2
BILL NO. 07 - THERMAL & MOISTURE PROTECTION - Page No. 7.2
Code
Description
Note:
SECTION G -THERMAL & MOISTURE PROTECTION (CONT'D)
Note:
Water tank Finishes
Note:
Floor Finish
Note:
Supply and install smooth reinforced concrete with potable water approved cementitious and all necessary works complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
A
To floors, Ref FF06
m2
228
Code
Description
Note:
Wall Finishes
Note:
Supply and install smooth reinforced concrete with potable water approved cementitious and all necessary works complete in accordance with specifications and drawings.
Code
Description
Remarks
Unit of Measurement
Quantity
B
To walls, ref. WF03
m2
307
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 -MECH INSTALLATION - Page No. 15.1
BILL NO. 07 -MECH INSTALLATION - Page No. 15.1
Code
Description
Note:
SECTION Q - MECHANICAL INSTALLATIONS
Note:
Rainwater, soil,  waste, and vent pipework installations complete in accordance with specifications and drawings
Note:
Pipework
Note:
above ground uPVC pipework including fittings, accessories, insect screen, and all necessary works complete in accordance with drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
A
82mm diameter
m
4
B
Pressure pipe 50mm
m
5
Code
Description
Note:
Under ground uPVC pipework including fittings, accessories, and all necessary works complete in accordance with drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
C
110mm diameter
m
1
Code
Description
Note:
Fittings, complete in accordance with drawings and specifications
Note:
Grating Cover
Code
Description
Remarks
Unit of Measurement
Quantity
D
Channel grating 6000x300mm
No
1
Code
Description
Note:
Sand Trap
Code
Description
Remarks
Unit of Measurement
Quantity
E
Sand trap 600x600x600mm
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.2
BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.2
Code
Description
Note:
SECTION Q - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Submersible Pump
Note:
Supply, install test and commission submersible pump set with control panels, valves, check valves, fittings, supports, flexible connections, electrical works, vibration isolation, electronic pressure controller, pressure gauges, protections and all required components and accessories as per drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
A
Summersible pump (1 duty/ 1 stand-by), capacity : 50 GPM @ 4m head
No
2
Code
Description
Note:
DOMESTIC HOT AND COLD WATER INSTALLATION
Note:
Cold Water Supply System
Note:
Supply and install cold water polypropylene  pipe works including necessary insulation, fittings, valves and accessories, and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Pump pipe 40mm
m
5
C
Transfer pipe 40mm
m
11
D
Incoming line 50mm
m
8
Code
Description
Note:
Fittings, complete in accordance with drawings and specifications
Note:
Isolating Valves
Code
Description
Remarks
Unit of Measurement
Quantity
E
40mm diameter
No
6
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.3
BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.3
Code
Description
Note:
SECTION Q - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Fittings, complete in accordance with drawings and specifications (Cont'd)
Note:
Copper Ionization Unit
Note:
Supply, install, test and commission copper ionization unit. Including short pipes, valves, complete with all fittings, supports and all required accessories as per drawings & specifications.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Copper ionization unit, flow rate 2.0 L/s
No
1
Code
Description
Note:
Pumps
Note:
Supply, install test and commission transfer water pumps set with control panels, valves, check valves, fittings, supports, flexible connections, electrical works, vibration isolation, electronic pressure controller, pressure gauges, protections and all required components and accessories as per drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
B
Water transfer pump set-01 , flow 2.0 L/S, head 3.5 Bar, (1 Duty, 1 Standby).
No
2
C
Water transfer pump set-02 , flow 2.0 L/S, head 3.5 Bar, (1 Duty, 1 Standby).
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.4
BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.4
Code
Description
Note:
SECTION Q - MECHANICAL INSTALLATIONS (CONT'D)
Note:
FIRE FIGHTING INSTALLATIONS
Note:
Supply and install black  steel fire fighting water pipe works including drain pipes, fittings, accessories valve and supports and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Fire pipe, 150 mm diameter
m
24
B
Fire pipe, 200 mm diameter
m
3
C
Fire pipe header, 200 mm diameter
m
3
Code
Description
Note:
Exhaust Pipe
Code
Description
Remarks
Unit of Measurement
Quantity
D
Diesel enging exhasut pipe 150mm
m
4
Code
Description
Note:
Chimney Exhaust
Code
Description
Remarks
Unit of Measurement
Quantity
E
Chimney exhaust terminated and discharge
No
1
Code
Description
Note:
Valves and other fittings complete in accordance with specification and drawings
Note:
Isolating Valve
Code
Description
Remarks
Unit of Measurement
Quantity
F
Isoating valve, 200mm
No
2
G
Isoating valve, 150mm
No
1
Code
Description
Note:
Breeching Inlet
Code
Description
Remarks
Unit of Measurement
Quantity
H
150mm dia X 4 Way breeching inlet for tank filling
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.5
BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.5
Code
Description
Note:
SECTION Q - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Fuel Tank
Note:
Supply, install, test and commission fuel tank including connections, pipes, access panel, fitting, accessories  and valves and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Fuel tank 300 ltrs with bund wall
No
1
Code
Description
Note:
Pumps
Note:
Supply, install, test and fire fighting pump set with control panels, fittings, supports, flexible connections, electrical works, vibration isolation, electronic pressure controller, pressure gauges, protections and all required components and accessories as per drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
B
Fire fighting combined pump set (Electrical, Diesel, Jockey) , flow 1000 GPM, @ 12 bar
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.6
BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.6
Code
Description
Note:
SECTION Q - MECHANICAL INSTALLATIONS (CONT'D)
Note:
AIR CONDITIONING SYSTEM AND VENTILATION INSTALLATION
Note:
Chilled Water Pipework
Note:
DX Unit
Note:
Supply, install, test and commission  DX unit cooling only including but not limited to indoor & outdoor units, vibration isolation, control wiring, flexible connectors, integral control, hanger, supports, filters, sleeves, condensate piping and all required accessories as per drawings and specifications.
Code
Description
Remarks
Unit of Measurement
Quantity
A
Ref. 05-SP-01 / CU/02-SP-01, air side 264 L/s
No
1
Code
Description
Note:
Fans
Note:
Supply and install fans including connections, fittings, back draft, and accessories and all necessary works complete in accordance with  specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Ref 05-EXF-01 dome type exhaust fan 300mm dia (weatherproof), flow rate 150 L/s
No
1
Code
Description
Note:
Building Management System (BMS)
Code
Description
Remarks
Unit of Measurement
Quantity
C
Supply, install, test and commissioning  of Building management system including points, wires, conduits, and  all necessary works complete in accordance with specifications and drawings
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.7
BILL NO. 07 -MECH INSTALLATION (Cont'd) - Page No. 15.7
Code
Description
Note:
SECTION Q - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Sundry / General Items
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for permits, connection and inspection fees associated with mechanical installations by utility and statutory authorities
Item
1
B
Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings
Item
1
C
Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment
Item
1
D
Allow for setting out the works, marking positions of holes, mortises, chases or the like
Item
1
E
Allow for testing and commissioning and submission of test certificates
Item
1
F
Allow for all identification labels, plates, charts and identification of plant, equipment, cable, isolators and the like
Item
1
G
Allow for preparing schedule of manufacturers recommended tools and spare parts for each piece of equipment
Item
1
H
Allow for the provision of operating/maintenance manuals
Item
1
J
Allow for providing shop and coordination drawings
Item
1
K
Allow for domestic water piping, sterilization and disinfections after commissioning
Item
1
L
Allow for fire stopping in accordance with the drawings, specification and local authorities requirements
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1
BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1
Code
Description
Note:
SECTION R - ELECTRICAL INSTALLATIONS
Note:
Power System
Note:
Final Distribution Boards
Note:
Supply, install, test, commission and maintain Final Distribution boards and terminations including bus bars, breakers, indicators, all interconnecting cables, wires termination and trays from main board,  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Final distribution boards, DB-PUMP
No
1
Code
Description
Note:
Power Distribution
Note:
Supply and install the following power fittings including all necessary accessories and connections to wiring  and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
13A Single switched socket W/P
No
1
C
13A Switched spur outlet
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2
BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2
Code
Description
Note:
SECTION R - ELECTRICAL INSTALLATIONS(CONT'D)
Note:
Power System (Cont`d)
Note:
Power point
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trucking, access box with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Power points
No
2
Code
Description
Note:
Isolating Switch
Note:
Supply and install isolating switch  including all interconnecting and terminations  and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Isolator single phase 32A IP65
No
2
C
Isolator three phase 32A IP65
No
2
D
Isolator single phase 40A IP65
No
1
E
Isolator three phase 500A IP65
No
1
Code
Description
Note:
Internal Lighting
Note:
Supply and install lighting including all necessary accessories  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
F
Lighting fixture,  type L1
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3
BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3
Code
Description
Note:
SECTION R - ELECTRICAL INSTALLATIONS(CONT'D)
Note:
Lighting System
Note:
Internal Lighting Points
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Internal Lighting points
No
2
Code
Description
Note:
Switches
Note:
Supply, install, test, commission switches including all necessary accessories  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
One gang, one way lighting switch 20A
No
1
Code
Description
Note:
Lighting switch Point
Note:
Supply and install wiring and conduit in concealed installation including cable trays / trucking, with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
Code / Note Title
Lighting switch points
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4
BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4
Code
Description
Note:
SECTION R - ELECTRICAL INSTALLATIONS(CONT'D)
Note:
Fire Alarm System
Note:
Supply, install, test, commission and maintain  the complete Analogue addressable fire Alarm & evacuation system including cabling, wiring conduit, cable tray, trunking, termination and power connections  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Intelligent optical smoke detector and standard base
No
1
B
Fire alarm sounder or horn W/P
No
1
C
Fire alarm junction box
No
1
D
Dual input module
No
1
E
Monitoring module
No
1
Code
Description
Note:
Earthing protection system
Note:
Supply, install, test and commissioning of earthing protection system including earth pits, conductors, bars ,bonds and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
F
Earthing protection
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5
BILL NO. 07 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Sundry / General Items
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for permits, fees, inspection associated with electrical installations by utility and statutory authorities
Item
1
B
Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment
Item
1
C
Allow for setting out the works, marking positions of holes, mortises, chases or the like
Item
1
D
Allow for testing and commissioning and production of test certificates
Item
1
E
Allow for all identification labels, plates, charts and identification of plant, equipment, cable, switches and the like
Item
1
F
Allow for the provision of operating / maintenance manuals
Item
1
G
Allow for providing shop and coordination drawings
Item
1
H
Allow for instructing selected employer's personnel on all aspects of the operation of systems and equipment
Item
1
J
Supply and handover to the client all tools and equipment in accordance with the specification
Item
1
K
Allow for fire stopping in accordance with the drawings specification and local authorities requirements
Item
1
L
Allow for all builders work in connection with the whole of the electrical installation including all manholes, sumps, pits etc.
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - SITE WORK - Page No. 2.1
BILL NO. 08 - SITE WORK - Page No. 2.1
Code
Description
Note:
DIVISION 02 - SITE WORKS
Note:
Site Preparation
Code
Description
Remarks
Unit of Measurement
Quantity
A
Site Clearance, including removal of rubbish, debris, vegetation within the designated work area and all necessary works complete accordance with the specifications and drawings
m2
24,415
Code
Description
Note:
Excavation
Note:
Excavation from existing level to bottom of foundation levels including all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Bulk excavation
m3
5,876
Code
Description
Note:
Disposal of Material Arising From Excavations
Code
Description
Remarks
Unit of Measurement
Quantity
C
Remove surplus excavated material from site to approved location including and all necessary works complete in accordance with specifications and drawings
m3
5,876
Code
Description
Note:
Demolition
Note:
Allow for carefully demolition of existing construction elements including, removing the rubbish from site, making good complete as shown on drawings and as specified.
Code
Description
Remarks
Unit of Measurement
Quantity
D
To boundary wall
m
22
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.2
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.2
Code
Description
Note:
DIVISION 02 - SITE WORKS (CONT'D)
Note:
Site Furniture And Equipment
Note:
Supply and installation of Site Furniture and equipment,  including excavation, filling, reinforcement, foundation, concrete, finishes, fixing, fittings, and all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Benches, ref. F-B-03A-1, F-B-03A-2, F-B-03B and F-B-03C
No
4
B
Trach bin, Ref. F-T-01
No
4
C
Inclusive seat, Ref. SW990207
No
1
D
Play panel 2 music, Ref. NRO613
No
1
E
Universal carousel, Ref. PCM157
No
1
F
Kids table, Ref. NRO212
No
1
G
Flex wheel, Ref. FSW226
No
2
H
Surface challenge 5, Ref. FSW225
No
2
J
COM BI 5, Ref. FSW105
No
2
K
Balance board, Ref. FSW231
No
2
L
Inclusive double chest press, Ref. FSW244
No
2
M
ARM bike, Ref. FSW240
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.3
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.3
Code
Description
Note:
DIVISION 02 - SITE WORKS (CONT'D)
Note:
Shade
Note:
Supply and installation shade structure,  including civil works, reinforcement, foundation, concrete, high density PVC fabric shade, hot dipped galvanized support frame & column and all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Shade parking
m2
2,161
Code
Description
Note:
Potable Security Room
Note:
Supply and install potable security room including finishes, power connection, accessories  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Size 2400 x 1800 mm
No
1
C
Size 2450 x 1850 mm
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.4
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.4
Code
Description
Note:
DIVISION 02 - SITE WORKS (CONT'D)
Note:
Boundary Wall
Note:
Boundary wall including excavation, backfilling, concrete work, reinforcement, formwork, waterproofing, finishes, metal gate, and all necessary work  complete accordance with the specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
To boundary wall, 3680mm high
m
5
B
To boundary wall, 4000mm high
m
174
C
To boundary wall, 4980mm high
m
39
D
To boundary wall, 5410mm high
m
8
E
To boundary wall, 5640mm high
m
12
F
To boundary wall, 5800mm high
m
10
G
To boundary wall, 5840mm high
m
16
H
To boundary wall, 6570mm high
m
16
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.5
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.5
Code
Description
Note:
DIVISION 02 - SITE WORKS (CONT'D)
Note:
Irrigation System
Note:
Supply and installation of Irrigation line piping including fittings installation accessories, with all related civil works such as excavation, levelling, compaction, laying and backfilling all in accordance with Drawings and Specifications.
Note:
PVC Filling Line
Code
Description
Remarks
Unit of Measurement
Quantity
A
Filling line 50mm diameter
m
3
Code
Description
Note:
Upvc Lateral Line Pipe CL10
Code
Description
Remarks
Unit of Measurement
Quantity
B
32mm diameter
m
1,819
C
50mm diameter
m
596
D
63mm diameter
m
177
E
90mm diameter
m
55
Code
Description
Note:
Allow Lateral Line Duct
Code
Description
Remarks
Unit of Measurement
Quantity
F
To pipe 32mm diameter
m
16
G
To pipe 50mm diameter
m
38
Code
Description
Note:
Irrigation Cable Decoder
Note:
Supply and installation of cable decoder with necessary conduit, fittings, fixings and accessories all in accordance with drawings and specifications.
Code
Description
Remarks
Unit of Measurement
Quantity
H
Cable decoder
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.6
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.6
Code
Description
Note:
DIVISION 02 - SITE WORKS (CONT'D)
Note:
Irrigation System(Cont'd)
Note:
Valves and other fittings complete in accordance with specification and drawings
Note:
Isolating Valves
Code
Description
Remarks
Unit of Measurement
Quantity
A
50mm diameter
No
1
Code
Description
Note:
Valves and Accessories
Note:
Supply and installation of valves with necessary conduit, wires, fittings, fixings and accessories all in accordance with drawings and specifications.
Code
Description
Remarks
Unit of Measurement
Quantity
B
Air valve 50 mm diameter
No
83
C
Air valve 63 mm diameter
No
2
D
Gate valve 90 mm diameter
No
1
E
Pull box
No
57
F
Drip riser point
No
1,009
G
Float Valve 50mm diameter
No
1
H
Solenoid valve SV01 1.5''
No
1
J
Solenoid valve SV02 1.5''
No
1
K
Solenoid valve SV03 1.5''
No
1
L
Solenoid valve SV04 1.5''
No
1
M
Solenoid valve SV05 1.5''
No
1
N
Solenoid valve SV06 1.5''
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.7
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.7
Code
Description
Note:
DIVISION 02 - SITE WORKS (CONT'D)
Note:
Irrigation System(Cont'd)
Note:
Valves and Accessories(Cont'd)
Note:
Supply and installation of valves with necessary conduit, wires, fittings, fixings and accessories all in accordance with drawings and specifications.(Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Solenoid valve SV07 1.5''
No
1
B
Solenoid valve SV08 1.5''
No
1
C
Solenoid valve SV09 1.5''
No
2
D
Solenoid valve SV10 1.5''
No
1
E
Solenoid valve SV11 1.5''
No
1
F
Solenoid valve SV12 1.5''
No
1
G
Solenoid valve SV13 1.5''
No
1
H
Solenoid valve SV14 1.5''
No
1
J
Solenoid valve SV15 1.5''
No
1
K
Solenoid valve SV16 1.5''
No
1
L
Solenoid valve SV17 1.5''
No
2
M
Solenoid valve SV18 1.5''
No
1
N
Solenoid valve SV19 1.5''
No
1
P
Solenoid valve SV20 1.5''
No
1
Q
Solenoid valve SV21 1.5''
No
1
R
Solenoid valve SV22 1.5''
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.8
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.8
Code
Description
Note:
DIVISION 02 - SITE WORKS (CONT'D)
Note:
Irrigation System(Cont'd)
Note:
Valves and Accessories(Cont'd)
Note:
Supply and installation of valves with necessary conduit, wires, fittings, fixings and accessories all in accordance with drawings and specifications.(Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Solenoid valve SV23 1.5''
No
1
B
Solenoid valve SV24 1.5''
No
1
C
Solenoid valve SV25 1.5''
No
1
D
Solenoid valve SV26 1.5''
No
1
E
Solenoid valve SV27 1.5''
No
1
F
Solenoid valve SV28 1.5''
No
1
G
Solenoid valve SV29 1.5''
No
1
H
Solenoid valve SV30 1.5''
No
1
J
Solenoid valve SV31 1.5''
No
1
K
Solenoid valve SV32 1.5''
No
1
L
Solenoid valve SV33 1.5''
No
1
M
Solenoid valve SV34 1.5''
No
1
N
Solenoid valve SV35 1.5''
No
1
P
Solenoid valve SV36 1.5''
No
1
Q
Solenoid valve SV37 1.5''
No
1
R
Solenoid valve SV38 1.5''
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.9
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.9
Code
Description
Note:
DIVISION 02 - SITE WORKS (CONT'D)
Note:
Irrigation System(Cont'd)
Note:
Valves and Accessories(Cont'd)
Note:
Supply and installation of valves with necessary conduit, wires, fittings, fixings and accessories all in accordance with drawings and specifications.(Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Solenoid valve SV39 1.5''
No
1
B
Solenoid valve SV40 1.5''
No
1
C
Solenoid valve SV41 1.5''
No
1
D
Solenoid valve SV42 1.5''
No
1
E
Solenoid valve SV43 1.5''
No
1
F
Solenoid valve SV44 1.5''
No
1
G
Solenoid valve SV45 1.5''
No
1
H
Solenoid valve SV46 1.5''
No
1
J
Solenoid valve SV47 1.5''
No
1
K
Solenoid valve SV48 1.5''
No
1
L
Solenoid valve SV49 1.5''
No
1
M
Solenoid valve SV50 1.5''
No
1
N
Solenoid valve SV51 1.5''
No
1
P
Solenoid valve SV52 1.5''
No
1
Q
Solenoid valve SV53 1.5''
No
1
R
Solenoid valve SV54 1.5''
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.10
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.10
Code
Description
Note:
DIVISION 02 - SITE WORKS (CONT'D)
Note:
Irrigation System(Cont'd)
Note:
Valves and Accessories(Cont'd)
Note:
Supply and installation of valves with necessary conduit, wires, fittings, fixings and accessories all in accordance with drawings and specifications.(Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
Solenoid valve SV55 1.5''
No
1
B
Solenoid valve SV56 1.5''
No
1
C
Solenoid valve SV57 1.5''
No
1
Code
Description
Note:
Water Meter
Code
Description
Remarks
Unit of Measurement
Quantity
D
Water monitoring meter for irrigation within valve chamber
No
1
Code
Description
Note:
Pumps
Note:
Supply, install test and commission pumps complete with control panels, valves, headers, check valves, fittings, supports, flexible connections, electrical works, vibration isolation, electronic pressure controller, pressure gauges, pressure vessel, protections and all required components and accessories as per drawings and specifications
Code
Description
Remarks
Unit of Measurement
Quantity
E
Irrigation pump, (1 duty), flow = ** l/s head** bar
No
1
F
Irrigation pump, (1 standby), flow = ** l/s head** bar
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.11
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.11
Code
Description
Note:
DIVISION 02 - SITE WORKS (CONT'D)
Note:
Hard Landscape
Note:
External Floor Finishes
Note:
Supply and install floor finish including all underlayment's, sand, subgrade, pointing, jointing complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
80mm thick interlock to entrance road
m2
1,100
B
60mm thick interlock to entrance road
m2
52
C
Precast concrete paving, ref. PA-01, size 200x400x60mm, greige color
m2
2,824
D
Precast concrete paving, ref. PA-02, size 200x400x60mm, dark gray color
m2
343.6
E
Precast concrete paving, ref. PA-03, size 200x400x60mm, light gray color
m2
725
F
Granite paving, ref. PA-04, size 100x100x60mm, black color
m2
1,035
Code
Description
Note:
Rubber flooring, including all underlayment's and all necessary work complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
G
Rubber, ref. PA-05, 20mm thick, blue color
m2
58
H
Rubber, ref. PA-06, 20mm thick, yellow color
m2
188
J
Rubber, ref. PA-08, 20mm thick, green color
m2
60
K
Rubber, ref. PA-09, 20mm thick, red color
m2
82
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.12
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.12
Code
Description
Note:
DIVISION 02 - SITE WORKS (CONT'D)
Note:
Hard Landscape (Cont'd)
Note:
External Floor Finishes  (Cont'd)
Note:
Reflexology garden, including all underlayment's and all necessary work complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Reflexology garden, ref. PA-10, light gray color
m2
72
Code
Description
Note:
Sand, including all underlayment's and all necessary work complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Sand, ref. PA-11, light gray color
m2
106
Code
Description
Note:
Supply and install asphalt road including compaction and all necessary work complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
60mm thick wearing course asphaltic concrete
m2
6,033
D
Prime coat
m2
6,555
E
200mm thick base course aggregate
m2
6,555
F
150mm thick sub base granular
m2
6,555
Code
Description
Note:
Supply and install Kerb stone including concrete  hunching, foundation, cement mortar, sand fill, waterproofing and painting complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
G
Upstand kerb stone 420x200mm
m
4,090
H
Flush kerb stone
m
377
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.13
BILL NO. 08 - SITE WORK (CONT'D) - Page No. 2.13
Code
Description
Note:
DIVISION 02 - SITE WORKS (CONT'D)
Note:
Landscape (Cont'd)
Note:
Soft Landscape
Note:
Supply and planting of trees, shrubs and ground cover as detail including excavation, filling, planting soil, irrigation water and pesticides, gravel, waterproofing any required complete in accordance with specifications and drawings
Note:
Tree
Code
Description
Remarks
Unit of Measurement
Quantity
A
Palm tree, ref. P-T-01
No
76
B
Cassia nodosa, ref. P-T-02
No
6
C
Pongamia blabra, ref. P-T-03
No
12
D
Plumeria rubra, ref. P-T-04
No
25
E
Lagerstroem ia indica, ref. P-T-05
No
13
F
Bauhinia variegata, ref. P-T-06
No
8
G
Albizia julibrissen, ref. P-T-07
No
4
Code
Description
Note:
Shrubs And Ground Cover Grass
Code
Description
Remarks
Unit of Measurement
Quantity
H
Bougainvillea glabra (pink), ref. P-S-01
m2
72
J
Jatropha integerrima (pink), ref. P-S-03
m2
308
K
Ruellia ciliosa (pink), ref. P-S-04
m2
808
L
Ipomoea, ref. P-S-05
m2
315
M
Ruellia brittoniana (pink), ref. P-S-06
m2
21
N
Paspalum vaginatum, ref. P-S-07
m2
6,990
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - ACCESSORIES - Page No. 10.1
BILL NO. 08 - ACCESSORIES - Page No. 10.1
Code
Description
Note:
DIVISION 10 - ACCESSORIES
Note:
Marking Paint
Note:
Supply and apply marking paint including  and all necessary works complete in accordance with specification , drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Marking paint line between parking
m
1,307
B
Marking paint stop line
m
173
C
Dashed center line
m
651
D
Right arrow
No.
6
E
Left arrow
No.
3
F
Straight arrow
No.
30
G
Straight with left arrow
No.
3
H
Straight with right arrow
No.
4
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - ACCESSORIES (Cont'd)- Page No. 10.2
BILL NO. 08 - ACCESSORIES (Cont'd)- Page No. 10.2
Code
Description
Note:
DIVISION 10 - ACCESSORIES(CONT'D)
Note:
Marking Paint
Note:
Supply and apply marking paint including  and all necessary works complete in accordance with specification , drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Left with right arrow
No.
2
B
Handicap sign
No.
7
C
Charger sign
m2
4
D
Pedestrian crossing 6200x4600mm
No.
1
E
Hatch paint Handicap area
m2
46
F
Parking numbers
No.
149
Code
Description
Note:
Wheel Stopper
Note:
Supply and install precast concrete wheel stopper including painting, all fittings, accessories and connections  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
G
Size 2000x150x120mm
No
148
Code
Description
Note:
Temporary Fence
Note:
Temporary corrugated fencing sheet during construction only with one secure pedestrian gate(1000mm) including steel support, steel post, precast concrete base, all fixing, fittings, accessories  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
H
Temporary fence, 2000mm high
m
406
Code
Description
Note:
Signage
Code
Description
Remarks
Unit of Measurement
Quantity
J
Supply and install external signage including all fittings, fixings, support, accessories and civil works all in accordance with specifications and drawings
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 -MECH INSTALLATION - Page No. 15.1
BILL NO. 08 -MECH INSTALLATION - Page No. 15.1
Code
Description
Note:
DIVISION 15 - MECHANICAL WORKS
Note:
MECHANICAL SITE WORKS
Note:
Drainage System
Note:
Supply, install, test and commission uPVC pipes complete with fittings, rubber gasket and accessories, warning tape, excavation, backfilling, thrust blocks, and all other accessories as per drawings and specification
Code
Description
Remarks
Unit of Measurement
Quantity
A
110mm diameter
m
133
B
200mm diameter
m
466
C
Suction line to holding tank, 100mm diameter
m
31
Code
Description
Note:
Manholes
Note:
Supply, and install, manhole complete with cover, rubber gasket and accessories, civil works, excavation, backfilling, ladders, and all other accessories as per drawings and specification
Code
Description
Remarks
Unit of Measurement
Quantity
D
B2-MH-01, size 600x600x450mm, with medium duty cover and vent and vent
No
1
E
B2-MH-02, size 600x600x560mm, with medium duty cover
No
1
F
B2-MH-03, size 600x600x650mm, with medium duty cover
No
1
G
B2-MH-04, size 600x600x830mm, with medium duty cover
No
1
H
B2-MH-05, size 600x600x950mm, with medium duty cover
No
1
J
B2-MH-06, size 800x800x1030mm, with medium duty cover
No
1
K
B2-MH-07, size 600x600x1150mm, with medium duty cover
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.2
BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.2
Code
Description
Note:
DIVISION 15 - MECHANICAL WORKS (CONT'D)
Note:
Manholes (Cont'd)
Note:
Supply, and install, manhole complete with cover, rubber gasket and accessories, civil works , excavation, backfilling, ladders, and all other accessories as per drawings and specification (Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
B2-MH-08, size 600x600x1300mm, with medium duty cover
No
1
B
B2-MH-09, size 600x600x450mm, with medium duty cover and vent
No
1
C
B2-MH-10, size 600x600x530mm, with medium duty cover
No
1
D
B2-MH-11, size 600x600x620mm, with medium duty cover
No
1
E
B2-MH-12, size 600x600x690mm, with meduim duty cover
No
1
F
B2-MH-13, size 600x600x780mm, with medium duty cover
No
1
G
B2-MH-14, size 600x600x1360mm, with medium duty cover
No
1
H
B2-MH-15, size 1000x1000x1360, with medium duty cover
No
1
J
B1-MH-01, size 600x600x450mm, with medium duty cover and vent
No
1
K
B1-MH-02, size 600x600x580mm, with medium duty cover
No
1
L
B1-MH-03, size 600x600x670mm, with medium duty cover
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.3
BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.3
Code
Description
Note:
DIVISION 15 - MECHANICAL WORKS (CONT'D)
Note:
Manholes (Cont'd)
Note:
Supply, and install, manhole complete with cover, rubber gasket and accessories, civil works , excavation, backfilling, ladders, and all other accessories as per drawings and specification(Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
B1-MH-04, size 600x600x850mm, with medium duty cover
No
1
B
B1-MH-05, size 600x600x950mm, with medium duty cover
No
1
C
B1-MH-06, size 800x800x1090mm, with medium duty cover
No
1
D
B1-MH-07, size 600x600x450mm, with medium duty cover and vent
No
1
E
B1-MH-08, size 600x600x510mm, with medium duty cover
No
1
F
B1-MH-09, size 600x600x580mm, with medium duty cover
No
1
G
B1-MH-10, size 600x600x670mm, with medium duty cover
No
1
H
B1-MH-11, size 600x600x740mm, with medium duty cover
No
1
J
B1-MH-12, size 600x600x770mm, with medium duty cover
No
1
K
B1-MH-13, size 600x600x890mm, with medium duty cover
No
1
L
B1-MH-14, size 800x800x1000mm, with medium duty cover
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.4
BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.4
Code
Description
Note:
DIVISION 15 - MECHANICAL WORKS (CONT'D)
Note:
Manholes (Cont'd)
Note:
Supply, and install, manhole complete with cover, rubber gasket and accessories, civil works , excavation, backfilling, ladders, and all other accessories as per drawings and specification (Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
B1-MH-15, size 800x800x1200mm, with medium duty cover and vent
No
1
B
B1-MH-16, size 600x600x450mm, with medium duty cover
No
1
C
B1-MH-17, size 600x600x620mm, with medium duty cover
No
1
D
B1-MH-18, size 600x600x740mm, with medium duty cover
No
1
E
B1-MH-19, size 600x600x910mm, with medium duty cover
No
1
F
B1-MH-20, size 800x800x1070mm, with medium duty cover
No
1
G
B1-MH-21, size 1000x1000x1270mm, with medium duty cover with vent
No
1
H
B2-MH-15A, size 600x600x450mm, with medium duty cover and vent
No
1
J
B2-MH-15B, size 600x600x570mm, with medium duty cover
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.5
BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.5
Code
Description
Note:
DIVISION 15 - MECHANICAL WORKS (CONT'D)
Note:
Manholes (Cont'd)
Note:
Supply, and install, manhole complete with cover, rubber gasket and accessories, civil works , excavation, backfilling, ladders, and all other accessories as per drawings and specification(Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
B2-MH-15C, size 600x600x690mm, with medium duty cover
No
1
B
B2-MH-15D, size 600x600x850mm, with medium duty cover
No
1
C
PRM, size 600x600x450mm, with medium duty cover and vent
No
1
Code
Description
Note:
Gully Trap
Note:
Supply, and install, gully trap complete with cover, and all other accessories as per drawings and specification
Code
Description
Remarks
Unit of Measurement
Quantity
D
Gully trap 300x300mm
No
20
Code
Description
Note:
Holding Tank
Note:
Supply, and install, holdign tank including civil work, complete with connections, pipes, fitting, accessories  and valves and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
E
Holding tank, dimension 7.50 x 2.2 x 3.0 m
No
2
Code
Description
Note:
Breaching Inlet
Code
Description
Remarks
Unit of Measurement
Quantity
F
4 way breaching inlet to holding tank
No
2
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.6
BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.6
Code
Description
Note:
DIVISION 15 - MECHANICAL WORKS (CONT'D)
Note:
Domestic Hot and Cold Water Installation
Note:
Cold Water Supply System
Note:
Supply and install cold water PVC pipe works including necessary, fittings, valves, excavation, backfill, accessories, and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Transfer line 40mm diameter
m
283
B
Filling line 50mm diameter
m
278
C
Ref. BCWS 20mm diameter
m
125
Code
Description
Note:
Duct Crossing
Code
Description
Remarks
Unit of Measurement
Quantity
D
Water supply pipe duct crossing 300x300mm
m
399
Code
Description
Note:
Valve Chamber
Note:
Supply and install valve chamber including and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
E
Valve chamber
No
3
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.7
BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.7
Code
Description
Note:
DIVISION 15 - MECHANICAL WORKS (CONT'D)
Note:
Fire Fighting System
Note:
Supply and install under-ground HDPE fire fighting water pipe works including drain pipe, fitting, accessories valve, excavation and backfilling, and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Fire pipe 150mm diameter
m
493
Code
Description
Note:
Duct Crossing
Code
Description
Remarks
Unit of Measurement
Quantity
B
Duct crossing to pipe 150mm
m
144
Code
Description
Note:
Equipment and Fittings as Specified
Note:
Isolating Valve
Code
Description
Remarks
Unit of Measurement
Quantity
C
Isolation valve in chamber 150mm
No
6
Code
Description
Note:
Fire Hydrant
Code
Description
Remarks
Unit of Measurement
Quantity
D
Private fire hydrant
No
6
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.8
BILL NO. 08 -MECH INSTALLATION (Cont'd) - Page No. 15.8
Code
Description
Note:
SECTION Q - MECHANICAL INSTALLATIONS (CONT'D)
Note:
Sundry / General Items
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for permits, connection and inspection fees associated with mechanical installations by utility and statutory authorities
Item
1
B
Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings
Item
1
C
Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment
Item
1
D
Allow for setting out the works, marking positions of holes, mortises, chases or the like
Item
1
E
Allow for testing and commissioning and submission of test certificates
Item
1
F
Allow for all identification labels, plates, charts and identification of plant, equipment, cable, isolators and the like
Item
1
G
Allow for preparing schedule of manufacturers recommended tools and spare parts for each piece of equipment
Item
1
H
Allow for the provision of operating/maintenance manuals
Item
1
J
Allow for providing shop and coordination drawings
Item
1
K
Allow for domestic water piping, sterilization and disinfections after commissioning
Item
1
L
Allow for fire stopping in accordance with the drawings, specification and local authorities requirements
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1
BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.1
Code
Description
Note:
DIVISION 16 - ELECTRICAL WORKS
Note:
ELECTRICAL SITE WORKS
Note:
Power System
Note:
Feeder Pillar
Code
Description
Remarks
Unit of Measurement
Quantity
A
Feeder pillar, ref FP-ED1 IP68
No
1
B
Feeder pillar, ref FP-POD1 IP68
No
1
C
Feeder pillar, ref FP-ED2 IP68
No
1
D
Feeder pillar, ref FP-POD2 IP68
No
1
E
Feeder pillar, ref FP-ED3 IP68
No
1
F
Feeder pillar, ref FP-POD3 IP68
No
1
Code
Description
Note:
Electrical Manhole
Note:
Electrical manhole with heavy duty cover, complete including, all civil works and accessories, and all other work as per drawings and specification
Code
Description
Remarks
Unit of Measurement
Quantity
G
Electrical manhole, size 800x800x800mm
No
28
Code
Description
Note:
Underground  Duct
Note:
Supply and install  of uPVC duct with fittings and accessories, including excavation, backfilling,, concrete encasement and all other work as per drawings and specification
Code
Description
Remarks
Unit of Measurement
Quantity
H
uPVC Duct, 50mm dia
m
400
J
uPVC Duct, 100mm dia
m
1,175
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2
BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.2
Code
Description
Note:
DIVISION 16 - ELECTRICAL WORKS (CONT'D)
Note:
ELECTRICAL SITE WORKS (CONT'D)
Note:
Cables
Note:
Low Voltage armoured cables including ducts, glands, connections, conduits, excavation, backfilling, manholes, warning tap, termination, trays  and all necessary works complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
4C.6mm2 fire rated XLPE/SWA/PVC  +1C.6 mm2 fire rated PVC/ECC/CU
m
212
B
2C.10mm2 XLPE/SWA/PVC  +1C.10 mm2 PVC/ECC/CU
m
55
C
4C.10mm2 XLPE/SWA/PVC  +1C.10mm2 PVC/ECC/CU
m
583
D
2C.16mm2 XLPE/SWA/CU/PVC  +1C.16mm2 CPC
m
269
E
2C.16mm2 XLPE/SWA/PVC  +1C.16mm2 PVC/ECC/CU
m
88
F
4C.16mm2 XLPE/SWA/PVC  +1C.16mm2 PVC/ECC/CU
m
273
G
4C.25mm2 XLPE/SWA/PVC  +1C.16mm2 PVC/ECC/CU
m
210
H
4C.95mm2 XLPE/SWA/PVC  +1C.50mm2 PVC/ECC/CU
m
216
J
2x 4C x 185mm2 XLPE/SWA/CU/PVC+ 2X1C x 95 mm2 CPC
m
424
K
2x 4C x 240 mm2 XLPE/SWA/CU/PVC+ 2X1C x 120 mm2 CPC
m
422
L
2x 4C x 150 mm2 fire rated XLPE/SWA/CU/PVC+ 2X1C x 70 mm2 fire rated CPC
m
55
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3
BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.3
Code
Description
Note:
DIVISION 16 - ELECTRICAL WORKS (CONT'D)
Note:
ELECTRICAL SITE WORKS (CONT'D)
Note:
Power Distribution
Note:
Supply and install the following power fittings including all necessary accessories and connections to wiring  and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
13A Single switched socket W/P
No
18
Code
Description
Note:
Power point
Note:
Supply and install wiring and conduit in concealed installation including duct, access box with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
B
Power points
No
18
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4
BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.4
Code
Description
Note:
DIVISION 16 - ELECTRICAL WORKS (CONT'D)
Note:
ELECTRICAL SITE WORKS (CONT'D)
Note:
Isolating Switch
Note:
Supply and install isolating switch  including all interconnecting and terminations  and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
Isolator single phase 32A IP65
No
5
B
Isolator single phase 40A IP68
No
2
C
Isolator three phase 40A IP65
No
2
Code
Description
Note:
External Lighting
Note:
Supply and installation of external lighting  including bases, conduit, wire, termination, with all necessary works, complete in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
D
External lighting fixture, type L-C-01
No
79
E
Ditto, type L-C-03
No
75
F
Ditto, type L-C-04
No
30
G
Ditto, type L-C-05
No
10
H
Ditto, type L-C-06
No
3
J
Ditto, type L-C-07
No
64
K
Ditto, type L-C-08
No
67
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5
BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.5
Code
Description
Note:
DIVISION 16 - ELECTRICAL WORKS (CONT'D)
Note:
ELECTRICAL SITE WORKS (CONT'D)
Note:
External Lighting Points
Note:
Supply and install wiring and conduit in concealed installation including conduit, excavation, backfill, with all accessories,   and all necessary works complete in accordance with specification and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
A
External lighting points
No
328
Code
Description
Note:
Fire Alarm System
Note:
Fire Alarm Manholes
Note:
Fire alarm manhole with cover, complete including, all civil works and accessories, and all other work as per drawings and specification
Code
Description
Remarks
Unit of Measurement
Quantity
B
Manholes, size 300x300x300mm
No
16
Code
Description
Note:
Underground  Duct
Note:
Supply and install  of uPVC duct with fittings and accessories, including excavation, backfilling,, concrete encasement and all other work as per drawings and specification
Code
Description
Remarks
Unit of Measurement
Quantity
C
uPVC Duct, 100mm dia
m
309
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6
BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.6
Code
Description
Note:
DIVISION 16 - ELECTRICAL WORKS (CONT'D)
Note:
ELECTRICAL SITE WORKS (CONT'D)
Note:
Telecom System
Note:
Telecom Manholes
Note:
Telecom manhole with cover, complete including, all civil works and accessories, and all other work as per drawings and specification
Code
Description
Remarks
Unit of Measurement
Quantity
A
Manholes, size 600x600x800mm
No
22
Code
Description
Note:
Underground  Duct
Note:
Supply and install  of uPVC duct with fittings and accessories, including excavation, backfilling,, concrete encasement and all other work as per drawings and specification
Code
Description
Remarks
Unit of Measurement
Quantity
B
uPVC Duct, 50mm dia
m
682
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.7
BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.7
Code
Description
Note:
DIVISION 16 - ELECTRICAL WORKS (CONT'D)
Note:
ELECTRICAL SITE WORKS (CONT'D)
Note:
Low Current Manholes
Note:
Low current manhole with cover, complete including, all civil works and accessories, and all other work as per drawings and specification
Code
Description
Remarks
Unit of Measurement
Quantity
A
Manholes, size 300x300x300mm
No
23
Code
Description
Note:
Underground  Duct
Note:
Supply and install  of uPVC duct with fittings and accessories, including excavation, backfilling,, concrete encasement and all other work as per drawings and specification
Code
Description
Remarks
Unit of Measurement
Quantity
B
uPVC Duct, 50mm dia
m
473
Code
Description
Note:
CCTV System
Note:
Supply install, test and commission complete CCTV system including rack, monitors, controllers , cabling, wiring, conduit and power connections, and all necessary works complete all in accordance with specifications and drawings
Code
Description
Remarks
Unit of Measurement
Quantity
C
ANPR cameras pole mounted
No
6
D
IES-Industrial ethernet switch
No
3
E
Bullet cameras pole mounted
No
33
F
Temporary bullet cameras pole mounted
No
8
G
Temporary IES-Industrial ethernet switch
No
2
H
12U Temporary CCTV rack
No
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.8
BILL NO. 08 - ELECTRICAL INSTALLATION (Cont'd) - Page No. 16.8
Code
Description
Note:
DIVISION 16 - ELECTRICAL INSTALLATIONS (CONT'D)
Note:
Sundry / General Items
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for permits, connection and inspection fees associated with electrical installations by utility and statutory authorities
Item
1
B
Allow for MEP coordination drawings with other trades i.e. reflected ceiling, walls and floors drawings
Item
1
C
Allow for all protective and decorative painting and cleaning of pipes, fittings and equipment
Item
1
D
Allow for setting out the works, marking positions of holes, mortises, chases or the like
Item
1
E
Allow for testing and commissioning and production of test certificates
Item
1
F
Allow for all identification labels, plates, charts and identification of plant, equipment, cable, switches and the like
Item
1
G
Allow for the provision of operating / maintenance manuals
Item
1
H
Allow for providing shop and coordination drawings
Item
1
J
Allow for instructing selected employer's personnel on all aspects of the operation of systems and equipment
Item
1
K
Supply and handover to the client all tools and equipment in accordance with the specification
Item
1
L
Allow for fire stopping in accordance with the drawings specification and local authorities requirements
Item
1
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 09 - PROVISIONAL SUM - Page No. PS.1
BILL No. 09 - PROVISIONAL SUM - Page No. PS.1
Code
Description
Note:
PROVISIONAL SUM
Note:
Authority Fees and Connection Charges
Code
Description
Remarks
Unit of Measurement
Quantity
A
Allow for amount of AED 650,000.00 (Six Hundred Fifty Thousand Dirham) for authority fees and connections including for supply and install of transformer and all necessary works, complete as per Engineer instruction and provided drawings & specifications.
sum
1
Code
Description
Note:
Dubai Municipality: Costs of connecting to the sewage system
Note:
'Dubai Electricity and Water Authority: Costs of connecting to electricity and water
Note:
'Security Industry Regulatory Agency: Costs of system adoption, technical inspection and system connection with Dubai Police
Note:
'Civil Defense Authority: Costs of accreditation and system connection with 24x7 smart civil defense monitoring system
Note:
'Etisalat/ Du: No specific costs as the service is connected to the main telephone room (Bulk Service), and the operator provides its own exchange system and internal distributions. The beneficiary party contracts directly with Etisalat for the required package and service provision.
Note:
'Roads and Transport Authority: According to the requirements of the beneficiary party and recommendations of stakeholders/ experts
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.1
BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.1
Code
Description
Note:
DAY WORK
Note:
SCHEDULE OF RATES FOR DAY WORKS
Note:
Labor
Code
Description
Remarks
Unit of Measurement
Quantity
A
Non-supervisory working foremen
Hr
100
B
Laborers/helpers
Hr
100
C
Scaffolders
Hr
100
D
Steel fixers
Hr
100
E
Drainage layers
Hr
100
F
Carpenters and Joiners
Hr
100
G
Plasterers
Hr
100
H
Block layers, masons and tile fixers
Hr
100
J
Plumbers
Hr
100
K
Painters
Hr
100
L
Plant and machinery operators and drivers
Hr
100
M
Electricians/A.C. mechanics
Hr
100
N
Welders
Hr
100
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.2
BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.2
Code
Description
Note:
SCHEDULE OF RATES FOR DAYWORKS (Cont'd)
Note:
Materials
Code
Description
Remarks
Unit of Measurement
Quantity
A
Building sand
m3
30
B
Aggregate (to pass 29 mm)
m3
25
C
Grade 40 ready-mix concrete
m3
20
D
Portland cement - grey
Tn
10
E
Sulphate resisting cement
Tn
10
F
Mild steel reinforcement bars (all sizes)
Tn
10
G
High tensile steel reinforcement bars (all sizes)
Tn
10
H
Epoxy coating to steel reinforcement (all sizes)
Tn
1
J
Use and waste only on timber in sawn formwork
m2
50
K
Use and waste only on timber in wrote formwork
m2
50
L
Solid concrete blocks 100mm thick
m2
50
M
Ditto, 200mm thick
m2
50
N
Hollow concrete blocks 100mm thick
m2
50
P
Ditto, 150mm thick
m2
50
Q
Ditto, 200mm thick
m2
50
R
Softwood for carpentry (any size)
m3
50
S
Hardwood for joinery (any size)
m3
50
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.3
BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.3
Code
Description
Note:
SCHEDULE OF RATES FOR DAYWORKS (Cont'd)
Note:
Materials (Cont'd)
Code
Description
Remarks
Unit of Measurement
Quantity
A
12mm plywood
m2
50
B
20mm plywood
m2
50
C
12mm blackboard
m2
50
D
Epoxy paint
liter
20
E
Vinyl acrylic emulsion paint
liter
20
F
Oil paint
liter
20
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.4
BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.4
Code
Description
Note:
SCHEDULE OF RATES FOR DAYWORKS (Cont'd)
Note:
Plant
Code
Description
Remarks
Unit of Measurement
Quantity
A
Portable compressor: 4.6 m3/min. including tools and hoses
Hr
100
B
Air compressor: 6 m3/min. including two hoses and tools
Hr
100
C
Concrete mixers: open drum o.30/0.20 m3
Hr
100
D
Concrete mixer: open drum 0.20/0.15 m3
Hr
100
E
Dumpers 0.53 m3 capacity
Hr
100
F
Dumpers 1.00 m3 capacity
Hr
100
G
Concrete vibrator poker 50 mm diameter, electric backactor
Hr
100
H
Excavators: 0.50 m3 bucket capacity
Hr
100
J
Excavators: 1.0 m3 bucket capacity
Hr
100
K
Mobile crane, 10 tone capacity
Hr
100
L
Generator sets: 50 KVA
Hr
100
M
Generator sets: 10 KVA
Hr
100
N
Water pumps 25 KW
Hr
100
P
Van or utility vehicle, 1.5 tonne pickup
Hr
100
Q
Three tonne pickup
Hr
100
R
Water tanker: 4000 gal. capacity
Hr
100
S
20 tonne tipper truck
Hr
100
T
30 tonne tipper truck
Hr
100
U
Concrete pump
Hr
100
V
Welding and cutting set
Hr
100
W
Scaffold, mobile tower 5.0 m high
Hr
100
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.5
BILL No. 10 - SCHEDULE OF DAY WORKS - Page No. DW.5
Code
Description
Note:
SCHEDULE OF RATES FOR DAYWORKS (Cont'd)
Note:
COLLECTION
Note:
LABOUR
Code
Description
Remarks
Unit of Measurement
Quantity
A
Add for profit and overheads %
DW-1
1
Code
Description
Note:
Total for Labour
Note:
MATERIALS DELIVERED TO SITE
Code
Description
Remarks
Unit of Measurement
Quantity
B
Add for profit and overheads %
DW-2, DW-3
1
Code
Description
Note:
Total for Materials
Note:
PLANT ON SITE
Code
Description
Remarks
Unit of Measurement
Quantity
C
Add for profit and overheads %
DW-4
1
Code
Description
Note:
Total for Plant
Note:
Summary for Dayworks
Note:
A) Total For Labour
Note:
B) Total For Materials Delivered to Site
Note:
C) Total For Plant On Site
TOTAL AMOUNT CARRIED TO TENDER (AED)
Section total included in total?
No
TENDER SUMMARY
TENDER SUMMARY
Code
Description
Total carried to Tender
TOTAL AMOUNT CARRIED TO TENDER (AED)
*
Bill No. 1
*
Bill No. 2
*
Bill No. 3
*
Bill No. 4
*
Bill No. 5
*
Bill No. 6
*
Bill No. 7
*
Bill No. 8
Sub-Total
Adjustment Item(In % if any)-Add*/Deduct %
Amount after Adjustment (AED)
Performanc Security
Insurance of Work
*
Bill No. 9  Provisional Sum
*
Bill No. 10 Day Works
Section total included in total?
Yes
Zoom 100%
Zoom 75%
Zoom 50%
Zoom 25%

سيناريو أولي لقيمة العقد

AED 1,150,000–4,600,000

السيناريو: 1 وحدة بسعر مفترض 1,000,000–4,000,000 درهم، مع 15٪ للتنسيق والتسليم. حزمة مفترضة واحدة لتنفيذ منشآت الإيواء؛ الملخص العام يتضمن جدول كميات. هذا السيناريو لا يسعر البنود منفصلة، ويتطلب التسعير النهائي مراجعة جدول الكميات والوثائق الفنية. ليست هذه ميزانية الجهة المشترية.

DOCUMENTS

الإعلان ووثائق المناقصة

راجعوا نطاق المشروع وترتيبات التعاون على هذه الصفحة.

التعاون في هذه الفرصة

أرسلوا رقم المشروع وقدراتكم وخبراتكم ذات الصلة وخطة التسليم. ننسق مراجعة الأهلية وتأكيد النطاق وإعداد العطاء محلياً.

تعاونوا معنا →

التخطيط للتعاون

أسئلة نوضحها قبل بدء التعاون

أرسلوا قدراتكم ومرحلة المشروع والموعد المستهدف لنتفق على الخطوة التالية.

أرسلوا ملخصكم ↗
ما نطاق شراء المشروع ومتى يغلق؟

tender_241969 / rfq_246695 — ملاجئ لكبار السن وأصحاب الهمم. Dubai Municipality. 2026-11-05 08:00 GST.

كيف نقرأ ملفات المشروع وننزلها هنا؟

راجعوا نطاق المشروع وترتيبات التعاون على هذه الصفحة.

ما المواد اللازمة للتعاون معكم في هذا المشروع؟

جهّزوا الطرازات والمواصفات المطابقة ومراجع التوريد أو الإنشاء وخطة التسليم المحلية والرد الفني؛ وراجعوا الكميات والقبول وشروط المشاركة وفق نطاق المشروع.

التواصل المباشر

الاستفسار عن المشاريع

أرسلوا إلينا ملخص مشروعكم.

للمناقصات، أرسلوا رقم المشروع وقدرات شركتكم. وللهدايا، حددوا المناسبة والكمية والموعد المستهدف. نتفق بعدها على الخطة وعرض السعر قبل التنفيذ.

إرسال بريد إلكترونيleon@aimuse.ae ↗
هاتف الصين / WeChat15601678377الرقم نفسه للهاتف وWeChat
تنزيل ملخص التعاون ↓